background image

 

 
Perimeter Pro 

B390100 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERA

TING MA

NU

AL

 

Summary of Contents for B390100

Page 1: ...Perimeter Pro B390100 OPERATING MANUAL ...

Page 2: ...educe or eliminate the transportation spill risk this system is designed to be emptied after each application Its unique compact design also reduces the risk of damaging your client s exterior property as you will no longer drag a long heavy hose around landscaping and other objects It s mobile practical and durable design makes it a valuable tool for all types of accounts In addition it gives you...

Page 3: ...UBLESHOOTING Page 18 SPRAY GUN Exploded Parts Page 19 Item s Product Codes and Descriptions Page 20 PERIMETER PRO FRONT VIEW Exploded Parts Page 21 Item s Product Codes and Descriptions Page 22 REAR VIEW Exploded Parts Page 23 Item s Product Codes and Descriptions Page 24 PARTS AND SERVICE Page 25 ...

Page 4: ...loves protective footwear and a respirator Refer to the insecticide label for specific instructions and other precautions LOADING UNLOADING The Actisol Perimeter Pro should be emptied of any product and or items to lighten the unit for loading into or out of service vehicle Remember water is over 8 pounds per gallon When loading or unloading the Actisol Perimeter Pro always assure that the vehicle...

Page 5: ...y 2 Grip unit with both slanted grips 3 As you lift unit keep it firmly against your body 4 Set unit in vehicle and roll forward 5 Secure unit in vehicle ADJUSTING THE HANDLE The Actisol Perimeter Pro features an adjustable handle which can be lowered to save on space and raised to improve mobility Raise the Handle 1 Push in on the two buttons located above the tank on the frame 2 With both button...

Page 6: ...for use in this type of equipment Contact your chosen distributor for information on insecticides currently labeled for use in equipment such as the Actisol Perimeter Pro Filling Mixing The Actisol Perimeter Pro is designed to be filled and refilled easily from any common hose spigot Before adding water be sure the blue valve on the inlet gap fill assembly above the tank is in the cross line posit...

Page 7: ...spigot or hose 5 Turn the blue valve on the inlet gap fill assembly to the inline position to allow flow into the tank NOTE Flow will not pass the blue valve on the inlet gap fill assembly above the tank until valve is turned to the inline position The inlet flow of the water comes from the top of the tank and will assist in the mixing of the product with the water 6 Be sure to replace the vacuum ...

Page 8: ...ment lever turn downward to a light fan spray You will hear a spitting noise as the air is being discharged out of the end of the spray gun Then move the spray adjustment lever back to the upper position on full pin stream the pump should begin to build full pressure While pump is running turn red priming valve on top of the tank in the cross line position for approximately one second then back to...

Page 9: ... prevents twisting and kinking of the hose 4 The flow is fully adjustable from cone misy to solid stream Pull the trigger to start the flow With the spray adjustment lever adjust the flow to desired spary output from fine cone mist to solid stream 5 Release the trigger and the flow will stop 6 The spray gun is rated at 250 psi Page 6 1 4 Inlet Compression Trigger Spray Adjustment Lever Tip Shroud ...

Page 10: ...O NOT assume fluid compatibility If the fluid is improperly matched to the pumps elastomers a leak may occur Pumps used to transfer hazardous or hot max temperature 170 F 76 C Viton only chemicals must be in a vented area to guard against the possibility of injury due to harmful or explosive liquid vapors Caution DO NOT operate the pump at pressures which cause the motor to exceed the amperes rati...

Page 11: ... of the pressure switch setting may cause severe overload or premature failure Refer to the SHURflo Service Bulletin 1031 for the adjustment procedure Failures due to improper adjustment of the pressure switch setting will not be covered under the limited warranty If the plumbing is restrictive or the flow rate is very low the pump may re pressurize the outlet faster than the fluid is being releas...

Page 12: ...Page 9 ...

Page 13: ...te data must be included with order Contact Environmental Delivery Systems Inc a SHURflo distributor or SHURflo directly to order the necessary repair kit NO ITEM DESCRIPTION 1 300226 Diaphragm Pump 12V DC 60 psi 2 300258 Pressure Switch Assembly 3 300259 Check Valve Assembly 4 300269 Upper Housing 5 300260 Bypass Non Bypass Valve Assembly 6 300261 Diaphragm Assembly 7 300261 Drive Assembly 8 3002...

Page 14: ...Page 11 ...

Page 15: ...BATTERY Page 11 ...

Page 16: ...Page 12 ...

Page 17: ...ulting in higher heat generation The 1202S battery charger transforms the 115VAC into 12VDC at about 100 000 Hz 1667 times faster than conventional chargers which requires a much smaller transformer and this results in a unit of smaller size low weight and improved efficiency Operating Instructions 1 Connect the charger to the battery 2 Connect the charger to an AC outlet The Green LED will turn O...

Page 18: ...tempting any maintenance Features 1 Totally Automatic Switch Mode Battery Charger Suitable for Gel Sealed Wet Lead Acid Batteries 2 12 Volts 1 Amp Constant Current Equivalent to 2 Amp Tapered Charger in Charging time 3 Input 115VAC Range 90VAC to 132VAC 4 Automatic Cut off and then True Float charging Can be left connected indefinitely without harming the battery 5 De sulfation of battery Increase...

Page 19: ...4 4 Ripple Voltage Very low 1 The peak to peak ripple voltage into a resistive load is less than 200mV for the output voltage above 12 VDC Charging Cycle Stages Condition Mode Current Voltage LED Indication Stage 1 Charging Pulse Mode Pulse Mode 1 A Pulsing 0 5 5 0V Flash Stage 2 Constant Current Mode CC Mode 1A 5 0V 14 7V Orange Stage 3 Constant Voltage Mode CV Mode Reduces from 1A Holds 14 7V Or...

Page 20: ...CV Constant Voltage mode Stage 3 Constant Voltage Mode CV LED Orange The charger holds the battery at 14 7V and the current slowly reduces When the current reaches 0 5CC this point called the Switch Point The Switching Point is one of the great features of this battery charger that can adjust the current automatically according to the battery capacity Other chargers are not capable of adjusting th...

Page 21: ...oth the batteries and any other circuits connected to the charger De sulfation of Battery The charger will remove loose sulfation and increase the battery life hard sulfation cannot be reversed Electromagnetic Interference EMI The charger will not generate excessive radiated or conducted emissions No interference with TV radio computer or other equipment Meets FCC Class B Size and Weight Length 3 ...

Page 22: ...ove any debris Inlet tubing plumbing for debris Inlet Outlet tubing severely restricted kinked Debris in pump inlet outlet valves Proper voltage with the pump operating 10 Pump housing for cracks LEAKS FROM PUMP HEAD OR SWITCH For loose screws at switch or pump head Switch diaphragm ruptured or pinched PUMP WILL NOT SHUT OFF Pressure switch equipped Output line closed and no leaks For air trapped ...

Page 23: ...GH OPEATION Mounting Feet that are compressed to tight Does the mounting surface multiply noise flexible For loose pump head or drive screws Is the pump plumbed with rigid pipe causing noise to transmit Page 19 ...

Page 24: ...ACTISOL PERIMETER PRO SPRAY WAND NO ITEM DESCRIPTION 1 300242 High Performance Spray Gun 2 300243 Coupling 1 2 FNPT x 1 4 FNPT 3 300263 Unvalved Nipple 1 4 NPT Page 20 ...

Page 25: ...ACTISOL PERIMETER PRO FRONT VIEW Page 21 Discharge Valve Assembly Gap Fill Assembly ...

Page 26: ...0300N Wheel Cap Lock 5 8 21 22 300119 Coupling 1 4 FNPT 22 300120 Hex Nipple 1 4 NPT 23 300245 Ball Valve 1 4 Specify Blue or Red 24 300238 1 4 NPT X 3 8 HB 25 300212 Street Elbow 1 8 X 1 4 FNPT 26 500114 Bulk Head Fitting 1 5 27 300220 Comp Fitting 1 8 NPT X 3 8 OD Tubing 28 300209 Nylon Plastic Tubing 3 8 Per Ft 29 300214 Tubing Support 3 8 Not Shown 30 300267 Compression Sleeve 3 8 Not Shown 31...

Page 27: ...ACTISOL PERIMETER PRO REAR VIEW Page 23 ...

Page 28: ...0300N Wheel Cap Lock 5 8 21 22 300119 Coupling 1 4 FNPT 22 300120 Hex Nipple 1 4 NPT 23 300245 Ball Valve 1 4 Specify Blue or Red 24 300238 1 4 NPT X 3 8 HB 25 300212 Street Elbow 1 8 X 1 4 FNPT 26 500114 Bulk Head Fitting 1 5 27 300220 Comp Fitting 1 8 NPT X 3 8 OD Tubing 28 300209 Nylon Plastic Tubing 3 8 Per Ft 29 300214 Tubing Support 3 8 Not Shown 30 300267 Compression Sleeve 3 8 Not Shown 31...

Page 29: ...he unit in a plastic bag before adding materials to carton Ship the unit with a description of the problem a contact name and phone number and a return shipping address to Environmental Delivery Systems Inc 314 Morningside Drive Friendswood TX 77546 NOTE Post Warranty service will be billed for parts labor packaging if needed and freight HINT Be sure to save your original factory packaging for fut...

Page 30: ... or assume obligation or liability on Environmental Delivery Systems Inc s behalf Environmental Delivery Systems Inc shall not be liable for any labor damage or other expense nor shall Environmental Delivery Systems Inc be liable for any indirect incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product or part Return Policy All units must b...

Page 31: ...Delivery Systems Inc 314 Morningside Drive Friendswood TX 77546 1 877 ACTISOL 1 877 228 4765 281 993 0019 Phone 281 993 1112 Fax www actisol com facebook com Actisol Copyright 2015 Environmental Delivery Systems Inc ...

Reviews: