background image

 

AW Series User Manual

 

 

 

 

 

AW

 

Series

 

User

 

Manual

 

 

Summary of Contents for AW Series

Page 1: ...AW Series User Manual AW Series User Manual ...

Page 2: ......

Page 3: ...Installation Notes 13 4 2 Front installation 13 5 Cable connection 18 5 1 Cable connection 18 5 2 Load quantity of main power cable and main network cable 18 5 3 Post installation inspection 18 5 4 Turn on the screen and see the performance 18 5 5 For software operation please refer to the software instruction manual 18 6 Product maintenance 19 6 1 Module replacement 19 6 2 Common installation pro...

Page 4: ... result in serious injury or death due to fire hazard electric shock or hitting by falling items Please read this manual carefully before installing powering operating and maintaining this product Follow safety instructions in this manual and on the product If you have any questions please seek help from Absen WARNING Risk Might cause equipment damage or risk WARNING Please read the manual before ...

Page 5: ...switch should be installed near the product and should be visible and easily accessed This way in case of any failure the power can be promptly disconnected Before using this product check all electrical distribution equipment cables and all connected devices and make sure all meet current requirements Use appropriate power cables Please select the appropriate power cables according to the require...

Page 6: ...olated from other area and ensure the working platform is securely and stably fixed In the absence of proper eye protection please do not look directly at the lit screen from within 1 meter Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes Warning Beware of loads when hanging LED lamps used on the modules are sensitive and can be damaged ...

Page 7: ...e 20 50 and the panels with special low temperature materials can be installed at 30 20 Preparation of maintenance tools List Type Acting on picture Adjustable wrench Fix the connecting piece of the box and tighten the M10 60 bolt Phillips screwdriver Disassembly module power supply receiving card adaptor plate Hex key Remove power box multimeter Measuring power lines and distribution boxes Small ...

Page 8: ...Service hotline 400 700 3278 Product description Pictures of panels Panel size 500mm 500mm Panel size 750mm 500mm Exploded Views ...

Page 9: ... Bit 14 Contrast 4500 1 Color temperature K 7000 Viewing angle horizontal vertical 160 125 Driving method 1 22 AC working voltage V Power Max Average W m2 730 243 Application parameters Storage temperature 40 60 Operating temperature 20 50 Storage humidity RH 10 85 Operating humidity RH 10 90 Protection grade front rear IP65 IP54 LED life H 100000 Module maintenance method Rear Maintenance methods...

Page 10: ...st 4500 1 Color temperature K 6500 Viewing angle horizontal vertical 160 130 Driving method 1 8 AC working voltage V 200 240 Power Max Average W m2 Physical parameters Storage temperature 40 60 Operating temperature 20 50 Storage humidity RH 10 85 Operating humidity RH 10 90 Protection grade front rear IP65 IP54 LED life H 100000 Module maintenance method Rear Maintenance methods of power supply o...

Page 11: ...o 4 types A module and B module used for normal standard panel C module and D module used for rotating installation panel Adopt A module and B module can be assembled into a normal standard panel Adopt C module and D module can be assembled into a rotating installation panel ...

Page 12: ... Output voltage range 4 2 4 6 4 6 VDC Input voltage range 0 40A A Pictures of Receiving card Physical picture of receiving card The A5S receiving card is connected to the Hub board through the card slot Meanwhile the Hub board is also connected to the module power supply and data cable The Hub board plays the role of transit ...

Page 13: ...ers some electrical parameters can be adjusted through the measuring instruments and they can indicate or send signals in case there is deviation from normal working state The components in the power distribution box of the LED display mainly include main switch AC contactor circuit breaker air switch arrester optional timer function card time delay unit voltage indicator current indicator Thermal...

Page 14: ...e phase voltage is 380V and the single phase voltage is 220V The input end of the distribution box is three phase five wire system with a three phase voltage of 380V and a single phase voltage of 220V at the output end 4 X 1 X in the table 4 represents L L L N line 1 represents PE line X represents the main cable size If the single phase voltage is 110V then the international copper core cable mod...

Page 15: ... front installation During installation the panel should be installed from the middle position at the bottom row of the steel structure and installed from bottom to top Fix the panel on the structure in turn with connecting plates and M10x60mm bolts In order to facilitate the front maintenance of the power supply box when the screen body is used for front installation against the wall a rear maint...

Page 16: ...during installation Left and right connection diagram M8 30 screws and nuts 6 Connected network cable and power supply Use the network cable output cable from the previous cabinet to pass through the network cable jack of the next cabinet and connect to the HUB board 7 Power on and test the power and network cables of the screen are plugged in well or not Before powering on please test the power s...

Page 17: ...ion direction of the module 4 3 Rear installation 1 Place the two boxes side by side on the steel structure and use the connecting piece to lock the connection hole on the top of the box Mounting piece on the top of the cabinet In order to avoid the dead light and the deformation of the box due to the collision of the box it needs to be handled gently when placing the box ...

Page 18: ...squeezed Rear installation the rear maintenance space of the screen should be reserved at 60cm 80cm 2 Installation of the bottom connection hole 3 Pass the left and right connection holes of the box with screws and lock with nuts Nut on the right side of the box Screws on the left side of the box M8 30 screws and nuts 4 Install the second row of cabinets and then screw the upper and lower cabinets...

Page 19: ...position between left and right boxes Screw fixing position between the upper and lower cases Please pay attention to the fixing screws between the left right boxes and the upper lower boxes when installing Left and right connection diagram M8 30 screws and nuts ...

Page 20: ...s 11pcs AW3 9 750X500 26pcs 16pcs 8pcs Post installation inspection After the cabling between panels use a multimeter to measure whether there is a short circuit at the AC input L N PE and DC output VCC GND If you find a short circuit please check the circuit carefully Make sure the circuits and cables are all right before powering the display and turning it on Pay attention to the working voltage...

Page 21: ... remove the module Note Please note the orientation of the module when installing the module Please place the arrow facing up 6 1 2 Rear installation module 1 Remove power box As above use an Allen wrench to unscrew the 10 Allen screws 2 Disassembly module unscrew the 8 hexagonal screws in order Note Please hold the handle of the module when loosening the last screw to prevent the module flip forw...

Page 22: ...e middle of the box push it to the front of the screen and then fix the module on the box Note Please note the orientation of the module when installing the module Please place the arrow facing up Arrow installation direction in the middle of the module 5 Tighten the screws of the module in order 6 Tighten the hexagon socket screws of the power box in turn ...

Page 23: ...ound cables from the power box and then remove the power box from the back of the screen Please be careful not to collide with the box when removing the power supply box it will cause damage to the box and power box 4 Replace a new power box 6 2 2 Rear maintenance power box For rear maintenance no need to remove the module just remove the 10 screws of the power box For prevent electric shock and p...

Page 24: ...er the M10 60 bolt is locked too tight 7 2 The panel cannot be fixed on the square tube frame 1 Check whether the 40 40 square tube is vertical 2 Check whether the distance between 40 40 square tubes is the same as the width of the panel which should be done before installation 7 3 Mask lifting and LED lamp knocking out 1 Handle the panel gently during transportation 2 Avoid squeezing between pane...

Page 25: ...s powered on and whether the running indicator is flashing 5 Replace the sending card 6 Connecting the computer to an LCD display check whether there is output on video card 7 Update the video card driver 8 Replace the computer 3 Whole screen pixelated blurred 1 Check whether the power plug of the receiving card is tightly inserted 2 Check whether the power cable of the receiving card is burnt out...

Page 26: ...d 4 Check whether the main data cable is inserted into the wrong data port 5 Check whether the sending card data port is malfunctioning 6 Re add the multi function card 7 Replace the multi function card 8 Replace the sending card 8 No full screen display 1 Check whether the setting of the playback window is normal 2 Check the output resolution of the video processor 3 Check the output window of th...

Reviews: