background image

 

 

 

 

TH-1.1 

A

BBPRN10

50039

 Re
v B

 / 27

.07

.2018

 

 

 

EN 
FR 
ES 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 

 

Page 1 

Thermostat, ABB-free@home Installation and Operation Instructions 

En

g

lish 

 

 

IMPORTANT

: Carefully read all instructions and safety 

information about this device before operation. Please leave 
this document with the homeowner for future reference. 

 

 

WARNING

: Installation must be performed by a licensed HVAC 

installer or electrical professional. Improper installation can 
cause property damage, personal injury, or loss of life. 

 

Intended Use 

The Thermostat is used as part of the ABB-free@home

®

 system. It 

controls the temperature and humidity in a house or an apartment. 
For information about the many functions of this device, see the system 
manual at www.abb.com/us/freeathome.  
 

Box Contents 

A - Thermostat  
B - Mounting Base  
C - 2 Wall Screws & 1 Anti-Theft Screw 
D - Wiring Labels   

Optional Accessory (not included):

 Trim Plate TH-TP-1-WH Hides 

holes/marks from old thermostat 

INSTALLATION 

 

1.  Turn OFF the power to the heating/cooling system by switching off the 

breaker or with the switch that controls the heating/cooling system. 
Check to make sure the old system is OFF by changing the 
temperature. If the system does not turn on within 5 minutes, the 
power is OFF. 

2.  Remove the old thermostat cover. Do NOT remove any wires from the 

thermostat. 

3.  Take a picture of the old thermostat’s wiring. 
4.  Label the wires with the wire labels provided. The ABB 

Thermostat requires a “C”-wire. If there is no “C”-wire the 
wiring must be changed. 

 

 

 

IMPORTANT

: The ABB Thermostat does NOT work with 120 V 

or higher! If the existing thermostat is labeled 120 V or 240 V, 
has thick black wires with wire nuts, or has L1 or L2 terminal 
blocks: DO NOT connect device!  

 
 

Wiring Connection  

(See Wiring Guide for more details) 

 
 

 

Conventional Setup 

Rc 

Cooling power, 24 V  

 

Rh 

Heating power, 24 V  

 

Common, 24 V (from Rc)  

 

Y1 

Cooling (stage 1)  

 

Y2 

Cooling (stage 2)  

 

Fan 

 

W1 

Heating (stage 1)  

 

W2 

Heating (stage 2)  

ACC 

For accessories*. 
Operated by the “AUX” 
symbol on the display.  

 

O/B 

Not used  

 
 
*  Typical accessories: humidifier or dehumidifier 

 

 

 

IC