background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                     

                                       

 

 

 

                               

 

                                                                                       

 

 

 

 

 

 

 

 

 

             

 

 

     

 

 

 

 

 

 

                       

               

 

 

 

READ AND STUDY MANUAL BEFORE USE 

             

 

AQUATRAP

®

 LGR Dehumidifier  

               Model AT150RS

 

OPERATING MANUAL

 

Summary of Contents for AQUATRAP AT150RS

Page 1: ...READ AND STUDY MANUAL BEFORE USE AQUATRAP LGR Dehumidifier Model AT150RS OPERATING MANUAL ...

Page 2: ...t Technologies Design and Development Specifications Model AT150RS Water Removal 90 F 90 RH 134Pints 63L per day Water Removal 81 F 60 RH 74Pints 35L per day Water Removal 50 F 70 RH 32Pints 15L per day Operating Temp Range 34 100 F Refrigerant R410A Max Power Consumption 850 Watt Voltage Cycle 115V 60Hz Amperage 7 5A Rated Air Flow 354 cfm 600 m3 h Control Panel Touch pad Defrost Type Sensor Cont...

Page 3: ...ranty Abatement Dehumidifiers are used by professionals for the drying out of wet materials such as carpets carpet cushions floors walls building contents and more They reduce the water in enclosed structural environments like buildings or parts of a building by removing water vapor from the air Safety Instructions Do not allow children to play with or around the operating unit Keep wiring and mot...

Page 4: ...temperature minimizing conditions that cause the coils to freeze up thereby engaging the defrost cycle CAUTION Never operate the Aquatrap dehumidifier at temperatures above 100oF It could damage the machine construction and internal components Error Messages Message Icon Description Er01 PUMP ON flashing Problem with pump or the drain tube is kinked Er02 N A Check coil temperature sensor at the si...

Page 5: ... once to display TIMER CLOCK time which reads 00 00 Press it again to display the TOTAL CLOCK time If the DISPLAY key has not been pressed within 15 seconds the CLOCK time will revert back to its default display When error messages appear TIMER TOTAL and JOB CLOCK displays disappear Press DISPLAY key once to get the clock displays back once errors are cleared Operating Your Dehumidifier Place the ...

Page 6: ...h which prompts the operator to either set the TIMER by pressing the TIMER KEY or to start the machine directly by pressing the START STOP KEY Pressing the ON OFF key again will turn the machine off The red indication light and LCD light go out Note In STANDBY MODE the machine will automatically turn off if there are no other keys pressed within 15 minutes TIMER By using the TIMER key the dehumidi...