Page 1: ...ator Assembly User Instructions for 3M Belt Mounted PAPR Assembly GVP 1 GVP 1U GVP CB GVP PSK2 GVP 614 SK and 3M PAPR Unit GVP 100 IMPORTANT Before use the wearer must read and understand these User I...

Page 2: ...inated air to enter the respirator headpiece and may result in sickness or death Failure to pass a user performance check and complete all necessary repairs before use may adversely affect respirator...

Page 3: ...fter battery has been charged Assembly Charge the battery pack 1 Inspect the battery pack prior to each charge cycle If the case is damaged do not charge the battery pack Properly dispose of the batte...

Page 4: ...o your waist and adjust for a snug fit Feed any excess belt length through the belt loop or cut to the desired length Belt GVP 117 GVP 127 or TR 326 when used with the TR 630 battery TR 659 battery Ad...

Page 5: ...indicator light located on the top of the adapter To power the motor blower off hold the power button on the adapter down for 3 seconds When there is approximately 15 minutes of charge left on the TR...

Page 6: ...s or cracks Bend the tube to verify it is flexible The breathing tube should connect firmly to the GVP motor blower If damage is noted replace with the appropriate breathing tube to match the respirat...

Page 7: ...nical Data Bulletin 223 Battery Maintenance for 3M Versaflo Respirator Systems for further instruction 3 Power cord The power cord may be wiped down with a mild cleaning solution taking care to avoid...

Page 8: ...e used to determine the assigned protection factor for the GVP PAPR system Consult 3M Technical Data Bulletin 175 for further information on APFs and supporting test data HE Filter Service Life The HE...

Page 9: ...ylamine HE AM MA HE GVP 445 Formaldehyde HE FM HE GVP 440 High Efficiency HE GVP Assembly with Li Ion Battery Non Intrinsically System a PAPR Unit Motor Blower GVP 100 b Power Cord GVP 610 c Battery P...

Page 10: ...nnected to the charger Allow battery pack and charger temperatures to moderate to between 50 F 10 C and 90 F 32 C Select the correct charger for the battery BC 200 or BC 210 does not work power base i...

Page 11: ...ly removed from the power base Frequent removal of the adapter module may damage electrical contacts in the power base and cause the charger to malfunction The 3M Smart Battery Charger BC 210 should b...