background image

Main Features

The 3M 9928 respirator provides lightweight, effective,

comfortable and hygienic respiratory protection against dusts,

mists and metal fumes. Its convex shape enhances wearer

comfort and allows a good fit over a wide range of face sizes;

the 3M™ Cool Flow™ exhalation valve reduces moisture

build-up, particularly in hot and humid work conditions. 

The 4-point adjustable straps and adjustable nose clip ensure

a proper fit.

The 3M 9928 Premium Welding Fume Respirator has been

designed specifically for welding applications to provide

protection against Ozone and welding fume, plus relief from

nuisance odours.

The 3M 9928 does not require costly and time-consuming

maintenance.

Applications

• Iron Foundries

• Potteries

• Steel Foundries

• Powdered Chemicals

• Ship Building/Ship Repairing • Metal Manufacture

• Battery Manufacture

• Paint Manufacture

• Welding and Soldering

• Construction

Approvals

The 3M 9928 has been shown to meet the Basic Safety

Requirements under Article 10 and 11B of the European

Community Directive 89/686. An EC-type examination

certificate No. 54976 is in force issued by the British Standards

institution and the product is produced at a manufacturing

location certified to ISO9002 by the British Standards

institution. The product is CE marked.

Materials

The following materials are used in the production of this product:

• Straps

-

Polyisoprene/Cotton fibre

• Nose-clip

-

Aluminium

• Filter

-

Polypropylene

• Nose foam

-

PVC

• Valve

-

Polypropylene

• Face seal Gasket

-

PVC

Weight: 13 g

Standards

The product has been tested to the NEW European Norm

EN149:2001 and has met the requirements of category FFP2

in this standard. 

The main performance tests in this standard are:

• Total Inward Leakage

Ten test subjects perform a series of exercises while walking

on a tread-mill. The amount of contaminant leaking into the

respirator through the filter, face seal and, where fitted, the

valve is measured. For category FFP2 the leakage must not

exceed 8% for eight out of the ten results.

• Filter Penetration

The filter efficiency of twelve respirators is tested against a

sodium chloride aerosol and a paraffin oil aerosol. 

For the FFP2 category both aerosol penetrations must be

below 6%

• Flammability

Four respirators are individually passed through a flame at

800°C ±50°C at a speed of 6 cm/sec. The respirators shall

not continue to burn after removal from the flame.

• Breathing Resistance

The resistance created by the respirator filter to an airflow of

30 L/min and 95 L/min are evaluated. For an FFP2 device this

must not exceed 0.7 mbar and 2.4 mbar at the respective flows.

• Information

A range of information, specified in this standard, must be

provided on the packaging of the product.

A full copy EN149:2001 can be purchased from your national

standards body.

Correct use

The respirator may be used in concentrations of solid, water

based and non-volatile liquid based aerosols up to 10 times

the Occupational Exposure Limit (OEL) BS4275:1997. 

It can also be used to protect the wearer against Ozone gas

generated in welding applications in concentrations up to

10 times the OEL.

9928 Premium Welding
Fume Respirator

Data Sheet

Reviews: