Prestige 2602HWL-D3A Support Notes
All contents copyright (c) 2007 ZyXEL Communications Corporation.
166
number 101.
Device B is P2602HWL-D3A, SIP1 number: 33333.
Phone 1 number: 33333, it is an analog phone, which connects to P2602HWL-D3A phone 1 port.
Phone 2 number: 22222.
Phone 3 number: 103, it is a PTSN phone.
In this graph, user Y use PSTN Phone (103) to dial P2602HWL-D3A FXO number 101, after
hears the “alter tone”, then dials User X SIP phone number 33333 and inputs password 123456,
and user X SIP phone (33333) will ring.
Configuration details
On Device A:
Step 1:
Choose “Activate Trunking”on P2602HWL-D3A web GUI:
VoIP > Trunking > General
.
Step 2: Set Auto Attendant Timeout 10 sec, Dialing Interval 3 sec on P2602HWL-D3A web GUI:
VoIP > Trunking > General.
Step 3: Choose Active Auto Attendant Authentication and set password 123456 on
P2602HWL-D3A web GUI:
VoIP > Trunking > General
, then click the
“Apply” button.
On Device B:
No special configuration needed.