![background image](http://html1.mh-extra.com/html/zyxel-communications/aam1008-61/aam1008-61_release-note_944516010.webp)
9. Power on AAM1008-61 and press any key within 3 seconds as indicated by the following figure.
10. Type “
atnb
” and then press Enter key on console window.
11. Wait for the firmware uploading to complete.
12. Use the following commands on AAM1008-61 to write the new firmware to flash memory.
- 192.168.1.1>
flashfs
- 192.168.1.1
flashfs>
update
13. Wait for the update to complete and then restart AAM1008-61.
Configuration Backup/Restore:
The AAM1008-61 uses FTP to backup/restore configuration through its built-in FTP server. You can
use any FTP client (for example, ftp.exe in Windows) to backup/restore AAM1008-61 configuration.
The procedure is as follows:
On management station:
C:\> ftp <AAM1008-61 IP address>
User name: <Enter>
Password: 1234
230 Logged in
ftp> get
init
ftp> put
init
ftp> quit
Where
User name:
just press <Enter>
Password:
the management password, 1234 by default
get init:
backup the configuration into local file - init
put init:
restore the configuration by local file - init
On AAM1008-61:
After management station has successfully put the configuration file and quitted the FTP client
application for restoring configuration, one just waits for updating completion and then AAM1008-61
will reboot automatically.
Do not power off
AAM1008-61 while the updating process is in progress.