Zylight reserves the right to make changes in design and/or improvements upon its
products without any obligation to include these changes in any products previously
manufactured.
No warranty, whether expressed or implied, is given or made with respect to any
accessory supplied with products described above. Except to the extent prohibited by
applicable law, all implied warranties made by Zylight in connection with this product,
including warranties of merchantability or fitness, are limited in duration to the warranty
period set forth above. No warranties, whether expressed or implied, including
warranties of merchantability or fitness, shall apply to this product after said period has
expired. The Consumer's and/or Dealer's sole remedy shall be such repair or
replacement as is expressly provided above.
This warranty is the only written warranty applicable to Zylight Products and
supersedes all prior warranties and written descriptions of warranty terms and
conditions heretofore published. Under no circumstances shall Zylight be liable for any
loss or damage, direct or consequential, arising out of the use of, or inability to use, this
product.
This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
Warranty Cont.
F.
G.
H.
Page 14
Pro-Palette
Electrical and Signal Connections
Attention:
Don’t connect or disconnect the PowerCon connector under load
or live! Connect the power connectors only with an authorized
and licensed technician!
Power
Conductor
USA
International
Live
(L)
Black
Brown
Neutral
(N)
White
Blue
Earth (E)
Green
Green and Yellow
DMX Signals
Pin # Signal
1 Common
2
Signal (-)
3
Signal (+)
4 ---
5 ---
Data connection:
(1) Connect a DMX signal to the male XLR socket of the fixture from
the controller.
(2) Insert a line to female XLR socket, and connect it to the next
fixture.
(3) Connect a terminator at the last fixture.
Instruction of data transmission reliability:
(1) Use a shielded twisted pair designed for RS-485: (standard
microphone cable is unsuitable for long-distances), and the
transmission distance of the 24AWG cable can exceed 300m (1000
feet). Cable with a larger wire diameter is needed for long-distance
transmission, and the signal amplifier may be needed.
(2) The number of fixtures connected with the single signal port should
not exceed 32.
(3) A resistor of 120 ohm / .5W will be needed between "signal +" and
"signal -" at both ends of a communication line link, so as to
avoid signal reflection interference. If a distribution amp is used, the
resistor will need to be connected at both ends of the communication
line respectively.