Page 1: ...Quick Installation Guide F O R S M A L L B U S I N E S S IP PHONE SYSTEM CooVox T600 ...

Page 2: ...erence attendees The equipped large capacity of 1TB hard disk can support and save up to 15 000 hours of call recordings Therefore CooVox T600 is ideal for enterprises demanding high performance and stability of IP PBX systems CooVox T600 can provide users with more convenience in application and management Thank you for using the ZYCOO IP PBX Please read the instructions carefully before use ...

Page 3: ...ONTENTS 1 Package Contents 2 Hardware Installation 2 Safety Precautions 6 Product Installation 11 Physical Connection 12 LED Definitions 13 Basic System Configuration 13 Web Login 14 Further Information ...

Page 4: ...ystem These are the items Included with your IP phone system purchase IP PBX T600 1PCS Power Adapter 1PCS Quick Installation Guide 1PCS Antenna only for GSM Warranty Card 1PCS Package Contents Two mounting brackets and fittings Network cable 1PCS ...

Page 5: ...e wrist strap and make sure that the wrist strap has a good skin contact and is well grounded The device works only under the correct power supply Please confirm that the power supply is consistent with the voltage marked by the device and it is suggested to use the included power supply Before the device is powered on please confirm that the power circuit will not be overloaded so as not to cause...

Page 6: ... the requirements described in the following subsection Please keep a proper temperature and humidity in the equipment room Too high low humidity may lead to bad insulation electricity leakage mechanical property changes and corrosions Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device For normal temperature and h...

Page 7: ... items Please set a 5 10cm gap around the device and keep the room well ventilated Please avoid placing any heavy object on the device 1 2 Electronic elements including capacitance and inductance on the device can be af fected by external interferences such as conducted emission by capacitance cou pling inductance coupling and impedance coupling To decrease the interferences please make sure to ta...

Page 8: ...e the device is specially designed for the usage of communication operators computer room please obey the following requirements for installation and maintenance Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20 000 As this instant current is strong enough to damage electronic devices more eff...

Page 9: ... at the same time Optional modules are as follows 4FXO Module 2WCDMA Module Check if the module is clean and intact Please ensure power of IP PBX is cut off Please ensure the direction of the module is correct ZYCOO logo side up Push the module into the module slot through the guide rail Tighten the locking screws on the both ends of the module 1 2 3 4 5 Phillips screwdriver ESD preventive wrist w...

Page 10: ...ot support hot plugging Caution To install the device in an EIA standard sized 19 inch rack follow the instructions described below Rack mounting Bracket Screw Check the grounding and stability of the rack Secure the supplied rack mounting brackets to each side of the device with supplied screws as illustrated in the following figure 1 2 PWR SYS WAN LAN 1 2 3 4 1 2 3 4 SLOT1 SLOT2 CooVox T600 ...

Page 11: ...sure the correct installation for the grounding of the rack which is the most important guarantee of avoiding ESD electricity leakage lightening and electromagnetic interference 2 Please mount devices in sequence from the bottom to top of the rack to avoid overloading 3 Please avoid any heavy thing placed on the device to avoid any unexpected accidents 4 Please ensure heat dissipation and air circ...

Page 12: ...er for the protection of lightening Users can try to choose the most appropriate measure according to different situation If CooVox U100 IP PBX is installed in the computer room and the room has dedicated Grounding bar then the using of ground wire to connect the device with the Grounding bar is put to the first consideration as shown in the following figure 1 IP PBX Rear panel 2 Grounding Termina...

Page 13: ...in the following figure If you intend to connect the device to the ground via the PE Protecting Earth cable of AC power cord please make sure the PE Protecting Earth cable in the electrical outlet is well grounded in advance Notes 1 IP PBX Rear panel 2 AC Power Cord with PE cable 4 L N 1 2 1 2 3 4 SLOT1 WAN LAN USB 1 2 3 4 SLOT2 HDMI PWR 100 240V AC ...

Page 14: ...11 Physical Connection 4 3 2 1 4 3 2 1 SLOT2 SLOT1 USB HDMI LAN WAN PWR 100 240V AC Power Adapter PSTN Router computer ...

Page 15: ...r On Power Off System Works System Fails Data Transport No Data Transport Module Loading Success Channel Ringing Module Loading Failure Module Loading Success Channel Ringing Module Loading Failure Module Loading Success Channel Ringing Module Loading Failure Module Loading Success Module Loading Failure CPE signal NET signal No signal L3 L4 E1 T1 PRI R2 Red Green Off Red Green SS7 signal MFCR2 si...

Page 16: ...68 1 xx if you are connected to WAN or 192 168 10 xx if you have connected to LAN Enter the device s default IP address into the browser address bar to access the Web interface WAN port https 192 168 1 100 LAN port https 192 168 10 100 Open a web browser preferably Firefox Google Chrome or IE 11 or higher Web Login 5 Use the default login credential to access the CooVox T600 After logging in pleas...

Page 17: ...urations please refer to the user manual If you have other questions please contact the ZYCOO local dealers or distributors from where you purchased this product ZYCOO Co Ltd Tel 86 28 85337096 Website www zycoo com Support support zycoo com Addr No 1602 16th Floor Building No 599 Century City South Road High tech Zone Chengdu Sichuan Province China ...

Page 18: ...15 ...

Page 19: ...16 ...

Page 20: ...Co Ltd Leading IP Phone System Provider Address No 1602 16th Floor Building No 599 Century City South Road High tech Zone Chengdu Sichuan Province China Telephone 86 28 85337096 ext 813 815 Website www zycoo com ...