Support for Association Groups
MP21ZS supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s
Association group_1:Z-Wave™ Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MP21ZS Status change report,
1. MP21ZS will trigger AUTO report function if the Switch status had been changed.
(ex.Switch Multilevel Report/Indicator Report/Central Scene Notification/ Device Reset Locally Notification)
Association group_2:basic set command on/off controlt
When the output of the MP21ZS is changed, On (0xFF) or Off (0x00). The MP21ZS will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command on/off controlt
When the output of the MP21ZS is changed, On (0xFF) or Off (0x00). The MP21ZS will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Restoring Factory Defaults
MP21ZS is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset:Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.