3.3. Assembling of the insulators
Insulators are recommended to be screwed when they are on the ground and then mounted on the
disconnector’s base frame using a crane.
Used elements:
1.
supporting insulator - 2 pcs.
2.
supporting insulator - 2 pcs.
3.
driving insulator - 1 pc.
4.
- screw M16x65 - 16 pcs.
- spring washer 16 - 16 pcs.
- nut M16 - 16 pcs.
5.
- screw M16x60 - 16 pcs.
- washer 17 - 32 pcs.
- spring washer 16 - 16 pcs.
- nut M16 - 16 pcs.
6.
- screw M16x40 - 4 pcs.
- washer 17 - 4 pcs.
- spring washer 16 - 4 pcs.
7.
- screw M16x50 - 4 pcs.
- spring washer 16 - 4 pcs.
- nut M16 - 4 pcs.
The insulators assembled on the base frame should be set in one plane. For that purpose is recommended usage
of cord, which provided from hole [1] axis to hole [2] axis enables insulators to be set in one plane [3].