Figure 2 

 

The  stand  makes  it  easy  to  carry  and  avoid  damages  when  trying  to  hold  it  by  other 

components.  The  microscope  is  provided  with  a  quadruple  inverted  nosepiece  to  make 

changing the sample easier and more comfortable  

The  stage  is  a  double  layer  mechanical  stage  with  translation  coaxial  knob  and  presents  a 

double clamp to hold up to two slides. The microscope is provided with a safety screw to fix 

the maximum upper position of the stage and avoid the stage to hit and damage the objectives 

(Figure 3). 

 

Figure 3 

The  coaxial  fine  and  focusing  knobs  are  at  an  ergonomic  position  and  are  equipped  with  a 

tension adjustment ring (Figure 4).  

 

 

Figure 4 

Summary of Contents for B-HC15

Page 1: ...o Le recomendamos leer atentamente el presente manual y seguir rigurosamente los procedimientos de uso para obtener las m ximas prestaciones y una mayor duraci n del mismo This manual should be availa...

Page 2: ...Uso del equipo 7 5 Mantenimiento 9 6 Causas de una mala imagen 9 7 Resoluci n de problemas 9 8 Recomendaciones pr cticas 10 9 Accesorios incluidos 11 English 12 1 Application 13 2 Description 13 3 Tec...

Page 3: ...ientos Si esto ocurre desenchufe inmediatamente el equipo de la toma de corriente Cualquier duda puede ser aclarada por su distribuidor instalaci n puesta en marcha funcionamiento Nunca desmonte el eq...

Page 4: ...a siguiente imagen Figura 1 Figura 1 Modelo triocular T HC16 Dependiendo del modelo el cabezal del microscopio puede ser binocular Modelo B HC15 o triocular Modelo T HC16 El cabezal tipo Siedentopf es...

Page 5: ...pulaci n de las preparaciones sea m s c moda La platina es mec nica de doble lecho con mando de traslaci n coaxial y dispone de una pinza para dos preparaciones el microscopio dispone de tornillo para...

Page 6: ...B HC15 T HC16 CABEZAL Binocular Triocular Tipo Siedentopf inclinado 30 y giratorio 360 Distancia interpupilar regulable 55 75mm ajuste de dioptr as en ambos oculares OCULARES WF10x 18 mm REV LVER Cu d...

Page 7: ...para ver qu resultados obtiene y si funciona correctamente e Inserte el enchufe en la parte trasera del equipo Inserte el otro extremo en la toma de corriente el ctrica Si las bater as est n cargadas...

Page 8: ...para subir la platina hasta que la preparaci n quede a unos pocos mil metros del objetivo A continuaci n gire suavemente el microm trico hasta conseguir una imagen enfocada g Una vez la imagen est bi...

Page 9: ...ec nicas limpias y secas g Desenchufe el cable de alimentaci n y desconecte el microscopio si no va a ser utilizado ajuste la intensidad de iluminaci n al m nimo y cubra el microscopio con la funda pr...

Page 10: ...llo gire el rev lver ligeramente a ambos lados hasta que este encaje correctamente Si existe polvo o suciedad visible en el campo de visi n Compruebe la existencia de polvo en la lente del precondensa...

Page 11: ...a pel cula de aceite ya que se deteriora en gran medida la imagen resultante c Se recomienda secar la lente frontal despu s de cada observaci n Nunca debe usarse gamuza Debe hacerse con un papel espec...

Page 12: ...In case it may happen unplug the equipment immediately If you have any doubt installation setting up operation please contact your distributor Never dismantle the different pieces of the microscope to...

Page 13: ...icroscope are shown on below image Figure 1 Figure 1 Trinocular model T HC16 Depending on the model the head can be binocular Modelo B HC15 o trinocular Modelo T HC16 The Siedentopf head is 30 incline...

Page 14: ...e comfortable The stage is a double layer mechanical stage with translation coaxial knob and presents a double clamp to hold up to two slides The microscope is provided with a safety screw to fix the...

Page 15: ...HBC015 HBC016 MODEL B HC15 T HC16 HEAD Binocular Trinocular Siedentopf type inclined 30 and rotary 360 Interpupillary distance adjustment 55 75mm diopter correction in both eyepieces EYEPIECES WF10x...

Page 16: ...plug into the socket at the back of the microscope Connect the other end to the electrical power supply If the batteries are charged the microscope can be used without connecting to the electrical pow...

Page 17: ...change to the next higher magnification objective and adjust focus by turning only fine focusing knob To change the objective turn the nosepiece until hearing a click sound and make sure it is well c...

Page 18: ...cover the microscope with the dust cover h To replace the fuse open the fuse holder with a flat screwdriver Remove the fuse and replace it 6 Causes of a defective image In case of a defective image yo...

Page 19: ...er or the eyepiece as well as the cleanliness of the sample Once you find out where the dirt is you should clean it as explained before If the sample gets fuzzy while observing Check the tension adjus...

Page 20: ...st focusing with the fine knob d We highly recommend drying the frontal lens after each use You should never use a duster Instead of it you should use specific optics cloth and liquids that are sold t...

Reviews: