ZUUM MAHCL4X4V2 Manual Download Page 8

 

 

 

Gateway: (Default 192.168.0.1) 

 

This function can setup MATRIX host intranet “Gateway”, press ENTER, the left-most number of second row will flash, then press the UP or DOWN button to 

change the numbers, , press LEFT or RIGHT to move to another location, the move to a position number will flash, press ENTER to complete the setting.   

 

DHCP Client: (Default Disable) 

 

When DHCP Clients setup to “Enable”, the MATRIX host will automatically get IP Address, Subnet Mask, Gateway, if setup as “Disable”, the MATRIX Host IP 

Address needs to go through “ ETHERNET” menu to set IP Address, Subnet Mask, Gateway, press ENTER, the second row will flash, then press the UP or 

DOWN to select DISABLE, ENABLE, then press ENTER to complete the setting. 

NOTE: If you set up as DHCP MAHCL4X4V2 Version up to (1.13 ) will 

note show the IP address. You will need to go into your router to confirm exact IP address that was assigned or use our IP Finder.exe tool to know 

what IP was assigned by your router. 

 

Media Type: (Default AUTO) 

 

This function can setup MATRIX host intranet    “Media Type, press the ENTER, the second row will flash, then press the UP or DOWN button to select AUTO

10MHalf

10MFull

100MHalf

100MFull, press ENTER to complete the setting. 

   

MAC Filter: (Default Disable)

 

 

MAC Filter can setup with registered MAC Address in order to connect the MATRIX host Web UI. MAC Address is required by the Web page to fill in, this 

function can only be setup as “DISABLE”, “ENABLE”, then press ENTER, the second row will flash, then press the UP or DOWN to select DISABLE, ENABLE, 

then press ENTER to complete the setting. 

 

4.8 EDID: (Default: 1080P LPCM-2CH) 
 

Because the player output display resolution will be based on TV EDID, the Matrix provides two default EDID modes:” BUILD-IN MODE” and “COPY MODE”. 

NOTE: 4K2K resolution you have to copy the EDID from your 4K2K monitor. 
 

   

 
 

 

Gateway   
192.168. 0. 100 

 

               

DHCP Client     
Disable 

Media Type     
AUTO 

MAC FILTER

 

 

DISABLE 

BUILD-IN MODE 
COPY MODE 

 

Summary of Contents for MAHCL4X4V2

Page 1: ...nect up to 4 HDMI sources to 4 HDMI displays TV s High definition video up to 4K2K 60Hz 8bits 1080p 60Hz 12bits Audio supports up to LPCM 7 1 192KHz Dolby TrueHD DTS HD MA Easy to use front panel control or included remote control for switching sources Built in Ethernet control assign IP or set up as DHCP and enter IP into browser for computer based control Built in RS232 console port for input ou...

Page 2: ...t indication LED off Output unlinked 3 1 Front Button Functions POWER Power on Blue Standby Red UP Up DOWN Down LEFT Left RIGHT Right ENTER Select confirm key MENU Back to main channel setting 3 2 LCD Panel Function Power on Main Screen When the power is on and the main screen appears Main MENU Option SETTINGS 1 SWITCH 7 ETHERNET 2 RS 232 8 EDID 3 IR TX 9 FIRMWARE VER 4 IR RX 10 KEYLOCK 5 HDBASET ...

Page 3: ...de HDBaseT RS 232 extender function works in two modes Enter RS 232 SETTING MENU press ENTER The will flash then press UP or DOWN button to select FIX MODE or MATRIX MODE Press ENTER key to confirm setting FIX MODE is one to one transmission RS 232 port 1 only works with HDBaseT port 1 RS 232 port 2 only works with HDBaseT port 2 and so on MAHCL4X4V2 RS 232 MATRIX MODE is based on the Status of th...

Page 4: ...T button to select the IR TX output to be modified Press UP or DOWN button to select O or X Then press ENTER to confirm setting O on X off HDBaseT 1 2 3 4 IR TX O X O X HDMI 4 RS232 4 HDMI 3 RS232 3 HDMI 2 RS232 2 HDMI 1 RS232 1 HDBaseT 1 HDBaseT 2 HDBaseT 3 HDBaseT 4 Projector Connect To PC 1 Projector Connect To PC 1 Projector Connect To PC 1 Projector Connect To PC 4 PC 1 PC 2 PC 3 PC 4 HDMI RS...

Page 5: ...another After entering HDBaseT IR ID menu press ENTER Then LCD second line of text will flash Press RIGHT or LEFT button to select the IR ID input to be modified Press UP or DOWN button to select the ID Then press ENTER to confirm setting When you finish the HDBaseT IR ID setting the HDBaseT remote controls IR1 must also be setted with the same ID in order to perform the right operations See 5 0 R...

Page 6: ...l IR1 must also be set to the same ID in order to operate normal When you finish the MATRIX IR ID setting the remote control IR1 that will control locally the matrix also is set with the same ID in order to perform the right operations See 5 0 Remote IR ID setting mode Press and hold the POWER button then press the number button which can be set from 0 to 9 total 10 groups See 5 0 These settings o...

Page 7: ...lash press ENTER to complete the setting NOTE If DHCP Client is set to ENABLE you can not change IP Subnet Mask Default 255 255 255 0 This function can setup MATRIX host intranet Subnet Mask press ENTER the left most number of second row will flash then press the UP or DOWN button to change the numbers press LEFT or RIGHT to move to another location the move to a position number will flash press E...

Page 8: ... IP address that was assigned or use our IP Finder exe tool to know what IP was assigned by your router Media Type Default AUTO This function can setup MATRIX host intranet Media Type press the ENTER the second row will flash then press the UP or DOWN button to select AUTO 10MHalf 10MFull 100MHalf 100MFull press ENTER to complete the setting MAC Filter Default Disable MAC Filter can setup with reg...

Page 9: ...pport higher resolution After entering COPY MODE menu press UP or DOWN button to select the OUTPUT TV 1 to 4 Then press ENTER to confirm 4 9 Version Display Matrix and WEB firmware version 4 10 Key lock Panel button IR remote lock function to avoid Matrix changes Under keylock mode press POWER MENU to unlock 4 11 Save Setting Save current channel setting total 10 sets available When enter SAVE SET...

Page 10: ...atrix Up Up same as Matrix Down Down same as Matrix Enter Confirm same as Matrix Menu Menu same as Matrix Quick key 1 Quick key 2 Quick key 3 Quick key 4 No function No function No function No function No function Turn off output No function No function Example to connect output port 1 to input port 4 press the quick key 1 OUTPUT 1 and then press the quick key 4 INPUT 4 6 0 REMOTE PC Control Funct...

Page 11: ...x IR ID EDID_COPY n Copy EDID from TX n SAVE n Save setting to n LOAD in Load setting from n KEY y Panel buttons IR remote control Lock Unlock DHCP y DHCP client on off IP_ADDRESS x x x x Set Matrix IP address SUBNET_MASK x x x x Set Matrix subnet mask GATEWAY x x x x Set Matrix gateway MEDIA_TYPE z Network speed select MAC_FILTER y Mac filter on off STATUS Show connection status VERSION Show firm...

Page 12: ...ets HDBaseT ports it sends out the IR signal by TX jack connect with 3 5 mm IR Emitter to control source device Rx Function Feeding IR signal to RX jack connect 3 5 mm IR Receiver cable it controls remote destinations at the 4 sets HDBaseT ports at the same time HDBaseT IR Function 1 Use IR1 remote control to control the Matrix input port switching from receiver side Works with IR CR01 IR receiver...

Page 13: ... Mask Gateway DHCP Client Media Type MAC Filter setting made by MAHCL4X4V2 ETHERNET MENU 5 HDBaseT IR operation Do not place IR emitter and receiver cable too close to avoid interference 6 HDBaseT RS232 under distribution mode is not able to send two devices simultaneously 10 Web Control Function Initial IP Configuration Setup MATRIX IP Address based on 4 7 ETHERNET section NOTE If you set up as D...

Page 14: ...f setup as Disable the MATRIX host IP Address Subnet Mask Gateway need to be set from Matrix console AUTO RESET The terminal connection will support 4 users on line at same time this function can setup the connect time to avoid long connections with users When over the set connect time the terminal will automatically disconnect the link 0 no time setup 1 255 Minute time range that can be setup Dev...

Page 15: ...me will update and correspond to SWITCH SETTING page Output Input Press Back jump back to advanced page MAC Filter MAC Filter can setup registered MAC Address to link MATRIX host Web UI up to 10 MAC groups After MAC Address entry select Enable and click Apply to complete the setting Press back to advanced page ...

Page 16: ... feet 100 meters IR Input Output 3 5mm Jack x 2 IR Carrier Frequency 30 60Khz IR Angle TX 30 degree RX 55 degree IR Distance Up to 16 feet 5 meters IR Receive Angle 45 degree IR Receive Distance Up to 16 feet 5 meters Browsers Supported IE Firefox Safari Chrome Power Adapter DC 12V 4 2 Amp Power Consumption 2 6 Amp Max Temperature Operation 0 to 55 C Storage 20 to 85 C Humidity up to 95 Dimensions...

Reviews: