Page 32
channel in any state.
【
Period
】
Set the time section of common recording, The recording will start only in the set range.
【
Record type
】
Set recording type: regular, detection or alarm.
Regular:
Perform the regular recording in the set time section. The video file type is “R”.
Detect:
Trigger the “motion detect”, “camera mask” or “video loss” signal. When above
alarm is set as opening recording, the “detection recording” state is on. The video
file type is “M”.
Alarm:
Trigger the external alarm signal in the set time section. When above alarm is set
as opening recording, the “detection recording” state is on. The video file type is “A”.
Note
:
Refer to chapter 4.3 to set corresponding alarm function.
4.2.2 Snapshot Storage
Setup snapshot parameters for different channels. At first time it's set for 24hours snapshot
continuously, please go to Main Menu->Record->Snapshot Storage for appropriate settings.
Note: If normal snapshot storage, please setup Snap at Main Menu->Advanced->Snapshot
(please refer to chapter 4.5.1 HDD Manage)
Picture 4.2
【
Channel
】
Select the related channel to set,click "all" to set all channels.
【
Presnap
】
Setup presnap picture quantity before recording,default is 5 pieces.