Overview:

Designed for modern commercial restrooms, the Sundara system delivers a superior user experience in both form and func-

tion. Crafted by world-class industrial designers Sundara combines seamless basin designs with curated faucets and soap 

dispensers, delivering a complete, easy to install hand washing solution.

Specifications:

Sundara

®

 Tide triple basin lavatory system manufactured by Zurn Industries. Lavatory shall be mounted at standard height to 

conform with ANSI, UFAS, TAS and ADA Accessibility Standards. Counter and integral basin to be constructed of Sundara

®

 

solid surface resin with aluminum trihydrate and other additives conforming to CSAB45.5/Z124 and IGC 156 standards. 

Shroud enclosure is constructed of satin finished type 304, 18 gage stainless steel designed for easy access with vandal 

resistant hardware. Lavatory is furnished complete with 0.5 gpm spray flow sensor operated faucet (specify model) and 

optional liquid soap dispenser (specify model), ½” quarter turn supply stops, 3/8” flexible supply risers, chrome 1 ¼” tail piece, 
and chrome 1 ¼” p-trap  for complete system operation. 

Paired Faucet Typical Specification 

(Refer to faucet manual for more details on specific model)

Voltage:  6 VDC Series [4 “AA” (Alkaline or Lithium) and/or external power option]

Sensor Range:  Self-calibrated, dependent upon sink depth and finish.

Operating Water Pressure: 10-125 psi

Operational Water Temperature: 33°F to 140°F (1°C to 60°C)

Aerator:  0.5 GPM Vandal-Resistant (Standard)

Paired Soap Dispenser Typical Specification 

(Refer to soap dispenser manual for more details on specific model)

Power Supply:   AC 110 V; DC 6V

Soap Viscosity:  100-3800 cps

Operating Temperature:  34

0

 - 131

0

F

Typical Dispensed Volume: 1.25 ml

Important Safety Information:

• Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances. 

• Do not convert or modify this Zurn product yourself. All warranties will be voided.

• 

Water supply lines must be sized according to building design in order to provide adequate water supply for each fixture.

• 

Flush all water lines prior to making connections.

• 

Minimum 3 people required for the sink installation.

• Au minimum, 3 personnes sont requises pour l’installation du lavabo.

Prior to Installation:

• 

If applicable, carrier (Z1240 series) is installed behind the wall. 

• Hot and cold water supply lines are installed as per building codes.

• 

Care shall be taken when installing this product to prevent damage of any exposed or decorative surfaces.

• 

Measure the drain outlet from the floor.

Be sure the sink/lavatory/basin is clear from any objects upon making the sensor to electronics connection initiating the self-

calibration feature. The sink must be clear of any and all objects in order to calibrate appropriately (calibration time approx 30-

60sec). Note:  Not applicable to manual faucet installations.

S’assurer qu’aucun objet ne se trouve sur l’évier/le lavabo/le bac lors du branchement du capteur sur l’électronique, ce qui lance la 

fonction d’auto-étalonnage. Rien ne doit se trouver sur le lavabo pour permettre son auto-étalonnage correct (temps

d’étalonnage de 30 à 60 s environ).

Summary of Contents for Sundara Z5006.03

Page 1: ... warranty of merchantabi lity is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods All weights stated in our catalogs and lists are approximate and are not guaranteed NOTE READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT NOTE The in...

Page 2: ...ndal Resistant Standard Paired Soap Dispenser Typical Specification Refer to soap dispenser manual for more details on specific model Power Supply AC 110 V DC 6V Soap Viscosity 100 3800 cps Operating Temperature 340 1310 F Typical Dispensed Volume 1 25 ml Important Safety Information Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances Do...

Page 3: ...ter Supply Items 6 8 P Trap Assembly 3 9 Sensor Faucet 3 10 Soap Dispenser If Ordered 3 11 5 16 18 Screw for Mounting L Bracket to Basin 12 12 10 24 Screw for Shroud 2 13 Coarse Screw for Wall Bracket 2 14 Oversize 5 16 Washer 12 15 3 8 16 Hex Bolt with washer 33 16 3 8 Toggle Never Drop Anchor 39 17 3 8 Fender Washer 33 18 5 16 x 2 5 8 Clevis Pin 2 19 18 8 SS Hairpin Cotter 2 6 8 5 4 7 9 10 11 15...

Page 4: ...chor next to each pivot point to prevent execessive flexing when shroud is in fully open position 3 1 4 84 34 863 29 1 2 752 28 3 4 733 14 3 4 378 1 1 2 36 3 1 4 80 4 102 6 152 15 381 90 2286 3 1 4 84 20 508 6 152 15 381 20 508 10 253 6 152 15 381 20 508 10 253 1 3 4 44 19 1 2 493 29 735 2 3 4 71 16 404 4 102 4 102 4 102 4 102 4 102 4 102 4 102 4 102 4 1 2 111 4 102 4 102 4 102 4 102 4 102 4 102 4...

Page 5: ...asin on its top surface on a cushioned surface Use socket wrench to torque the screws approximately 4 5 complete turns bottom out approximately 5 ft lbs of torque Warning Do not overtighten the screws Avertissement ne pas trop serrer les vis 11 15 Faucet Installation For ease of installation lay basin on its back Refer to faucet installation guide for details ...

Page 6: ...e of installation lay basin on its back Install the soap spout on right or left soap hole as applicable Refer to soap dispenser installation guide for details For ease of installation lay basin on its back Place grid draininto drainage opening Fasten washer and nut from underside of basin ...

Page 7: ...ied toggle anchors to wall and secure the hanger bracket s directly to the plywood with the supplied bolts Install hanger bracket to wall per structural rough in Note An offset might be necessary on applications using tile to get the basin and mounting brackets flush with wall and mating to bracket The plywood should not be visible after basin and shroud installation The bracket needs to be checke...

Page 8: ...d Warning Must be handled by at least 3 people Warning Ensure the basin back edge is completely supported in the wall bracket Avertissement s y prendre à trois minimum Avertissement s assurer que le bord arrière du bac est complètement soutenu par le support mural Mounting Bracket Bolt supplied by installer to attach the plywood to wall studs 16 15 17 Plywood Wall Stud ...

Page 9: ...er to soap dispenser installation guide for details Installing with Carrier Option Warning Must be handled by at least 3 people Avertissement s y prendre à trois minimum Refer to Carrier Rough in Installation guide for details Optional Waste Line Sleeve WL Z1240 EZR Carrier System ...

Page 10: ...ch P Trap to tailpiece Shroud Installation Step 1 Align wall bracket as shown and install coarse screw on each side Mark the slots in the wall bracket on the wall Note Anchors and bolts location can be flexible base on on site wall studs location Note A minimum of one anchor next to each pivot point is required to prevent excessive flexing when shroud is in fully open position 13 13 Pivot Point Pi...

Page 11: ...rked Ensure that wall studs are not immediately behind the marked hole locations prior to drilling Install anchor toggle bolts into previously drilled holes in walls Step 3 Re install wall bracket with coarse screws in previous location Then fasten the wall bracket with 3 8 bolts through each holes and into the toggle bolts Step 2 16 15 ...

Page 12: ...he shroud will likely need to be rotated upward slightly in order to install each pivot After one pivot is installed retain clevis pins with the included cotter pins Step 5 Rotate the shroud up to the basin until the threaded hole in the L bracket in visible through the slot in the shroud Then install the screw shown and repeat for the other side Step 4 18 19 12 12 ...

Page 13: ...n wash the surfaces and rinse with water Avoid exposing solid surface basin with strong chemicals such as acetone based cleaners and solutions If surfaces are exposed to these chemicals quickly rinse the surface with water Repair Instructions Zurn recommends that damages should be repaired by certified solid surface fabricator or repair agents Blemishes to the basin surface such as scratches burn ...