(A) REMOVABLE STOPPER INSTALLATION
Install the complete pop-up assembly without the stopper.
Drop the stopper in the pop-up so that the bottom ledge of
the stopper rests on top of the pivot rod.
(B) NON-REMOVABLE STOPPER INSTALLATION
Before installing the pivot rod and strap assembly, insert the
stopper into the pop-up. Assemble pivot strap assembly to
pop-up body so that the rod goes through the lower opening
of the stopper.
1.
Apply putty underneath the flange
of body (1).
2.
Apply teflon tape to the tailpiece
(5) and thread into body (1).
3.
Place grid drain assembly down
through lavatory sink.
4.
Install housing gasket (2), flat
gasket (3) and nut (4). Tighten nut.
5.
Remove excess putty from flange (1).
1.
Remove aerator and open valve to mixed position.
2.
Turn water on for 1 minute.
3.
Check for leaks under the sink.
4.
Shut off faucet and replace aerator.
NOTE TO INSTALLER:
When using vandal proof aerator (-VP) or flow control (-FC), keep the installation key fixed under sink or in
known location for future use. Keep installation instructions with faucet for future reference.
Faucet Test and Adjustment
Testing Procedures
Grid Drain
1
2
3
4
5
1.
Remove handle.
2.
Remove limit stop from cartridge.
3.
Turn water on. Set to desired maximum temperature.
Clockwise rotation of stop increases temperature and
counterclockwise rotation of stop lowers temperature.
4.
Re-install limit stop so that the lug on cartridge touches
lug on stop.
5.
Re-install handle.
SETTING PROCEDURES
Temperature Limit Stop
ITEM
DESCRIPTION
1
BODY
2
HOUSING
GASKET
3
FLAT
HOUSING
GASKET
4
NUT
5
TAILPIECE
GRID DRAIN ASSEMBLY
____________________________
INSTALLATION INSTRUCTIONS
Stopper Assembly
Form #
CF952
Date:
12/16/11
Product No.:
IS7440
C.N. No.
128418
Rev.
i
Sheet 3 of 4