background image

Technology 

Installation

Orbital Shower Panel R3

5-06-0012

Publication date 2021-08-27

Summary of Contents for OAS Standart R3

Page 1: ...Technology Installation Orbital Shower Panel R3 5 06 0012 Publication date 2021 08 27 ...

Page 2: ... document may be reproduced or copied in any form or by any means without written permission from Orbital Systems The English language version of this document contains the original instructions All other language versions are translations of the original instructions ...

Page 3: ... Tank Lock 8 Install Funnel 10 Install Orbital Shower Core 10 Install Hose Connections 13 Install Panel 14 Install Control Dial 14 Install Panel Lock 17 Next Step 20 Installing the Shower Head 22 Installing the 3rd Party Shower Head 24 Installing the Hand Shower 25 Installing the Diverter and Hand Shower 25 Installing the Hand Shower Holder 28 Shower Activation Wi Fi Setup and Installation test 31...

Page 4: ...This page is intentionally left blank Page 4 of 33 ...

Page 5: ...g Planning regulations BBR The system is type approved according to RiSE Research Institutes of Sweden AB with Type Approval Certificate C900373 C900374 Orbital Shower is CE marked based on test reports from third party labs If industry regulations and instructions in this manual are followed Orbital Systems guarantees a functional shower system Page 5 of 33 ...

Page 6: ...consent Defects that appear under conditions of operation not provided for and under improper use of the product Defects caused by faulty or non occurring maintenance incorrect installation or a faulty repair For showers outside of the warranty period spare parts are available for purchase directly from Orbital Systems Service Orbital Systems and our team of expert staff are available to assist yo...

Page 7: ...Sensor Cable 9 Recirculation Hose 10 Flush Hose 11 Filter Capsule 12 Cleaning Tablet 13 Clip 14 Sensor Tank Dock 15 Sensor Tank Lock 16 Spring Lock Install Sensor Hose Flush Hose and Recirculation Hose 8 9 10 1 Install Sensor Cable Flush Hose and Recirculation Hose Make sure the Sensor Cable goes first 2 Pull the Sensor Cable out to where the contact almost reaches the end of the Sensor Tank Page ...

Page 8: ... practice Make sure that the o rings are lubricated Connect Hoses to Sensor Tank Dock 2 Lock Hoses by inserting Clip 3 Insert Sensor Tank Dock into Connection Pipe Push it all the way in 4 Lock Sensor Tank Dock in place with the Spring Lock Install Sensor Tank and Sensor Tank Lock 6 15 Page 8 of 33 ...

Page 9: ...onnectors by aligning the two white lines 2 Insert Sensor Tank 3 Lock the Sensor Tank in position with the Sensor Tank Lock by turning it 90 degrees CAUTION Make sure Sensor Tank is inserted correctly The edge of the Sensor Tank should be fully pushed towards and in level with the edge of the Drain Unit Page 9 of 33 ...

Page 10: ... 5 NOTICE Place the Funnel with the hole oriented to the left Placing the hole oriented to the right will disable recirculation Install Orbital Shower Core 2 1 Remove Transport Plugs before installation Page 10 of 33 ...

Page 11: ...vy equipment The Orbital Shower Core weighs approx 25 kg CAUTION Make sure to attach the Safety Wire before tilting the Orbital Shower Core CAUTION Make sure Hoses and Cables are not pinched or kinked 3 WARNING Electrical installation should be performed according to local regulations by a licensed electrician 4 Page 11 of 33 ...

Page 12: ...5 x1 M8 socket head 6 CAUTION Make sure to have correct alignment between key and slot in connectors Make sure locking ring snaps and connector is locked Page 12 of 33 ...

Page 13: ...Install Hose Connections 1 RSK 188 24 82 Provided by Customer Hose Connections x2 1 2 CAUTION Install Hose Connections according to local regulations and adaptations Page 13 of 33 ...

Page 14: ...3 Install Panel 3 x8 M3 5 5mm driver Install Control Dial 7 Page 14 of 33 ...

Page 15: ...1 Position the Control Dial according to the up marking before assembly 2 CAUTION Risk of damage to Panel if overtightening x4 Plastite screw 12 mm Page 15 of 33 ...

Page 16: ...3 4 CAUTION Make sure to have correct alignment between key and slot in connectors Make sure locking ring snaps and connector is locked 5 Adjust Panel angle Page 16 of 33 ...

Page 17: ...6 Adjust x4 M3 5 5 mm driver Secure Install Panel Lock 4 1 NOTICE Clean surface before attaching Bracket Page 17 of 33 ...

Page 18: ...2 Adjust until edge aligned to edge Adjust until edge aligned with magnet 3 Page 18 of 33 ...

Page 19: ...4 5 Adjust Panel depth Page 19 of 33 ...

Page 20: ...ked position Next Step 11 CAUTION The Orbital Shower will not function without executing following steps Filter Capsule has to be installed before starting the Orbital Shower See User Guide for details Page 20 of 33 ...

Page 21: ... Systems Shower Head Installing the Shower Head 22 Follow steps valid for 3rd Party Shower Head Installing the 3rd Party Shower Head 24 Follow steps valid for Orbital Systems Hand Shower Installing the Diverter and Hand Shower 25 Installing the Hand Shower Holder 28 and Installing the Hand Shower 25 Page 21 of 33 ...

Page 22: ... 1 1 Shower Head Wall Mount 2 Shower Head Arm 3 Shower Head 1 It is recommended to cut the Wallbox UNI Push with the LK Wall Box Cutter UNI 2 2 mm 3 NOTICE Cover the end of the Shower Water Connector with thread sealant to avoid leakage Page 22 of 33 ...

Page 23: ...4 CAUTION Make sure not to cross thread and not to overtighten 5 Shower Head installation completed Page 23 of 33 ...

Page 24: ...lling the 3rd Party Shower Head Install 3rd Party Shower Head Go to www orbital systems com for more information about installation of 3rd Party Shower Heads in combination with Orbital Shower Page 24 of 33 ...

Page 25: ... 3 7 8 4 4 5 9 6 2 1 10 11 1 Diverter Valve House 2 Diverter Wall Plate 3 Diverter Knob 4 MC6S M4 x 8H A2 hexagon screw x3 5 Diverter Housing Cover 6 T25 screw 50 mm 5 5 mm x2 7 T8 2 5 x 8 mm screw 8 Torx T8 L key tool 9 Diverter Bottom Cap 10 Hand Shower 11 Shower Hose 1 Page 25 of 33 ...

Page 26: ...Drill 4 holes 6 mm in marked locations CAUTION Only drill through the tile itself no deeper CAUTION Seal drill holes according to local regulations or best practice 1 2 3 4 1 2 A Wood Concrete B Waterproofing membrane C Tile adhesive D Tile Page 26 of 33 ...

Page 27: ...AUTION It s important that the PEX Conduits are pushed in all the way to stop before cutting to the correct length of 18 mm 18 mm 6 CAUTION Do not run water through the Diverter before Diverter Housing Cover is mounted x2 MC6S M4 x 8H A2 hexagon screw Page 27 of 33 ...

Page 28: ... NOTICE Use Torx T8 L key tool in kit x1 T8 2 5 x 8 mm screw Installing the Hand Shower Holder Component Overview 3 2 1 4 1 Hand Shower Cover 2 T25 stainless steel screw 50 mm 5 5 mm x2 3 Hand Shower Bracket 4 M4 x 8 set screw Page 28 of 33 ...

Page 29: ...1 x2 T25 stainless steel screw 50 mm 5 5mm 2 Push Hand Shower Cover into position and use the Set Screw to lock it NOTICE Use Torx T8 L key tool in kit Page 29 of 33 ...

Page 30: ...3 Hand Shower installation completed Page 30 of 33 ...

Page 31: ...l Systems from App Store or Google Play and follow the instructions provided in the app Internet Connection is required Either password protected 2 4 GHz 5 GHz Wi Fi network or Ethernet is required IMPORTANT Ethernet is a factory added option It is not possible to use Wi Fi as connection method after the shower has been prepared for Ethernet Page 31 of 33 ...

Page 32: ...This page is intentionally left blank Page 32 of 33 ...

Page 33: ...C E R T I F I E D S P A C E T E C H N O L O G Y ...

Reviews: