ZURN plumbSMART ZEMS-IS Series Installation, Operation, Maintenance And Parts Manual Download Page 14

FV696  Rev. B   07/29/20

Page 12    

MetroVantage

® 

Repair Kits

1

2

3

4

5

6

14

15

18

19

20

21

22

23

16

17

8

9

10

11

12

24

13

26

25

27

28

29

30

31

32

33

34

35

36

7

1. 

Valve Body

2. 

Vacuum Breaker Friction Washer

3. 

Vacuum Breaker Insert

4. 

Vacuum Breaker Duckbill

5.  Main Seat

6.  Internal Kit

7. 

Valve Body Cover Gasket

8. 

Valve Body Cover

9.  Tailpiece

10.  Snap Ring

11. 

Tailpiece O-Ring

12.  Locking Ring

13. 

Stop Valve

14.  Piston Seal

15.  Piston

16.  Stop Spring

17. 

Guide O-Ring

18.  Piston Guide

19.  Guide Holder

20. 

Adjusting Screw

21.  Stop Cap

22. 

Snap Cap Screw Cover

23. 

Vandal-Resistent Control Stop Cover

24. 

Set Screw for Control Stop Cover

25. 

Sweat Solder Adapter

26. 

Supply Cover Tube

27.  Setscrerw for Cast Wall Escutcheon

28.  Cast Wall Escutcheon

29. 

Vacuum Breaker Tube

30. 

Vaccum Breaker Tube Nut

31.  Spud Nut

32.  Spud Friction Washer

33. 

Spud Sleeve

34.  Spud Escutcheon

35. 

ZEMS-IS-W1 Actuator

36.  ZEMS Escutcheon

Part Identification

Cover and Repair Kits

Product No.

Outside Cover

, Items 8

P6200-LL

Outside Cover O-Ring, Item 7

P6200-L12

Main Seat, Item 5

P6000-S-30

Water Closet Kit – 1.28 GPF, Items 5-6

P6200-EC-HET

Water Closet Kit – 1.6 GPF

, Items 5-6

P6200-EC-WS1

Water Closet Kit – 3.5 GPF, Items 

5-6

P6200-EC

Urinal Kit – 0.125 GPF, Items 5-6

P6200-EU-ULF

Urinal Kit – 1.0 GPF, Items 5-6

P6200-EU-WS1

Urinal Kit – 1.5 GPF, Items 5-6

P6200-EU

Adjustable Tailpieces

Product No.

Adjustable Tailpiece for Standard Flush Valve,

Items 9-11

P6000-J1

Tailpiece Coupling Assembly, Items 10-12

P6000-K

Tailpiece Locking Ring, Item 10

P6000-C30

Tailpiece O-Ring, Item 11

P6000-C31

Coupling Nut, Item 12

P6000-C32

Flush Connections and Spud Coupling Kits

Product No.

Flush Tube Assembly for Concealed Flush Valves

 

Refer to Section Q in Aqua Parts Guide

 

Specify ‘L’ Dim and Valve Used

P6000-Q_ _-

Vacuum Breaker Repair Kit, Items 2-4

P6000-B

Spud Coupling Assembly (Specify Size)

P6000-HN

Control Stop Repair Kit and Parts

Product No.

Control Stop Repair Kit for 1” and 3/4”, 

 

Items 14-20

P6000-D-SD

Seal Seat for 1” and 3/4”, Items 14

P6000-D42

Sweat Solder Connection

P6000-YBA

Vandal-Resistent Cover, Item 23

P6000-VC

Summary of Contents for plumbSMART ZEMS-IS Series

Page 1: ...nsequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the product...

Page 2: ...This Page Intentionally Left Blank ...

Page 3: ...In the event of valve failure fixture must be able to handle a continuous flow Be certain power is off to prevent damage to electrical components and or personal injury Features Zurn s AquaVantage TPE Diaphragm Clog resistant triple filter or linear filter by pass Chloramine resistant Dual seal Zurn s MetroVantage Piston Clog resistant by pass Chloramine resistant Proprietary dezincification resis...

Page 4: ...cept any interference received including interference that may cause undesired operation The following information refers to Zurn Smart Connected Products types W1 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference intended for us...

Page 5: ...nal Flush Connection for Water Closet Hand Drill Measuring Tape 1 3 4 Bit Sweat Solder Connection with Cast Wall Flange Control Stop with Vandal Cap optional with AquaFlush Endpoint ZEMS IS W1 Actuator Valve Body Parts List Required Tools Smooth Jawed Wrench Flat Head Screwdriver ...

Page 6: ...th items over water supply pipe Press wall escutcheon flush against finished wall and tighten set screw with hex wrench supplied to secure it in place Using a flat head screwdriver turning counterclockwise flush supply line by opening the control stop Turning clockwise will close the control stop 2 Gallon 1 Install control stop assembly by threading it onto water supply pipe and tightening with a ...

Page 7: ...Determine the length of vacuum breaker tube required to join the flush valve and fixture spud and cut if necessary Slide the tube nut spud nut slip gasket rubber gasket and spud escutcheon over the vacuum breaker tube and insert tube into fixture spud Hand tighten tube nut to valve body and hand tighten spud nut onto fixture spud Adjust the valve assembly for plumb Tighten fixture spud nut vacuum ...

Page 8: ...t through wall opening as shown below 3 1 8 13 8 Center line of Flush Valve Height of Stop Valve 1 3 4 Hole Through Wall Top Of Fixture Connect power and data cables from ZEMS IS W1 actuator to power and data extension cables from Endpoint through the hole Install actuator escutcheon to the actuator pipe with setscrew toward actuator Do not tighten setscrew at this time With escutcheon loose and h...

Page 9: ...y be performed by a licensed electrician 3 Connect power cord with Wago connector as outlined on the left See P6000 HW6 installation manual for detailed instruc tions 4 Each pair of endpoint and actuator should be wired in parallel as shown in the diagram below and should be connected us ing the optional P6000 MJ Mini Junction Box or crimp lugs 5 For installing a single pair of endpoint and actuat...

Page 10: ...ur specific ZEMS IS W1 model Activating the Motor Actuator with the Sensor To activate the motor actuator with the sensor simply place a target in front of the sensor A single red light will flash indicating the sensor has recognized the target If the target stays in view for eleven seconds two flashing red lights will occur This indicates that the target has been in view for the required time and...

Page 11: ...pped below minimum operating range Steps should be taken to increase the line pressure Water splashes out of fixture Supply volume is more than is necessary Adjust downward on control stop Lime accumulation on vortex or spreader holes of fixture Remove the lime build up Flush is not considered quiet Control stop is not adjusted for quiet operation Adjust the control stop for quiet operation keepin...

Page 12: ... restricted access Contact organization IT department No lights are flashing Gateway is not powered Power gateway Portal High daily use alerts Usage spiked Adjust threshold possibly move to portal area Endpoint is not appearing on portal Endpoint was not registered on plumbSMART Register device in plumbSMART Device is not communicating alert See endpoint troubleshooting See endpoint troubleshootin...

Page 13: ... 2 4 13 P6000 EUA ULF RK P6000 EUA WS1 RK P6000 EUA WS RK Control Stop Repair Kit and Parts Product No Control Stop Repair Kit for 1 and 3 4 Items 14 20 P6000 D SD Seal Seat for 1 and 3 4 Items 14 P6000 D42 Sweat Solder Connection P6000 YBA Vandal Resistent Cover Item 23 P6000 VC Repair Part Inside Part Product No Urinal Relief Valve Item 6 P6000 EU13 Closet Relief Valve Item 6 P6000 EC13 1 Valve ...

Page 14: ...r Kits Product No Outside Cover Items 8 P6200 LL Outside Cover O Ring Item 7 P6200 L12 Main Seat Item 5 P6000 S 30 Water Closet Kit 1 28 GPF Items 5 6 P6200 EC HET Water Closet Kit 1 6 GPF Items 5 6 P6200 EC WS1 Water Closet Kit 3 5 GPF Items 5 6 P6200 EC Urinal Kit 0 125 GPF Items 5 6 P6200 EU ULF Urinal Kit 1 0 GPF Items 5 6 P6200 EU WS1 Urinal Kit 1 5 GPF Items 5 6 P6200 EU Adjustable Tailpiece...

Page 15: ...This Page Intentionally Left Blank ...

Page 16: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev B Date 07 29 20 C N No 142895 Prod Dwg No FV696 ...