ZURN plumbSMART ZEMS-IS Series Installation, Operation, Maintenance And Parts Manual Download Page 1

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase. 

Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the 

goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance with instructions. We shall 

not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or consequential damages. The sole and exclusive 

remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his 

intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability 

is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a period of three years and 

shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are approximate and are not guaranteed.

NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT

AquaFlush

®

, AquaVantage

® 

,

  

and

 

MetroVantage

® 

Connected ZEMS-IS Series

Sensor-Operated Flushometer  

for Water Closets and Urinals
Installation, Operation, Maintenance,  

and Parts Manual

ZEMS6200-IS-W1

ZEMS6203-IS-W1

ZEMS6003-IS-W1

ZEMS6003AV-IS-W1

ZEMS6000-IS-W1

ZEMS6000AV-IS-W1

Summary of Contents for plumbSMART ZEMS-IS Series

Page 1: ...nsequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the product...

Page 2: ...This Page Intentionally Left Blank ...

Page 3: ...In the event of valve failure fixture must be able to handle a continuous flow Be certain power is off to prevent damage to electrical components and or personal injury Features Zurn s AquaVantage TPE Diaphragm Clog resistant triple filter or linear filter by pass Chloramine resistant Dual seal Zurn s MetroVantage Piston Clog resistant by pass Chloramine resistant Proprietary dezincification resis...

Page 4: ...cept any interference received including interference that may cause undesired operation The following information refers to Zurn Smart Connected Products types W1 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference intended for us...

Page 5: ...nal Flush Connection for Water Closet Hand Drill Measuring Tape 1 3 4 Bit Sweat Solder Connection with Cast Wall Flange Control Stop with Vandal Cap optional with AquaFlush Endpoint ZEMS IS W1 Actuator Valve Body Parts List Required Tools Smooth Jawed Wrench Flat Head Screwdriver ...

Page 6: ...th items over water supply pipe Press wall escutcheon flush against finished wall and tighten set screw with hex wrench supplied to secure it in place Using a flat head screwdriver turning counterclockwise flush supply line by opening the control stop Turning clockwise will close the control stop 2 Gallon 1 Install control stop assembly by threading it onto water supply pipe and tightening with a ...

Page 7: ...Determine the length of vacuum breaker tube required to join the flush valve and fixture spud and cut if necessary Slide the tube nut spud nut slip gasket rubber gasket and spud escutcheon over the vacuum breaker tube and insert tube into fixture spud Hand tighten tube nut to valve body and hand tighten spud nut onto fixture spud Adjust the valve assembly for plumb Tighten fixture spud nut vacuum ...

Page 8: ...t through wall opening as shown below 3 1 8 13 8 Center line of Flush Valve Height of Stop Valve 1 3 4 Hole Through Wall Top Of Fixture Connect power and data cables from ZEMS IS W1 actuator to power and data extension cables from Endpoint through the hole Install actuator escutcheon to the actuator pipe with setscrew toward actuator Do not tighten setscrew at this time With escutcheon loose and h...

Page 9: ...y be performed by a licensed electrician 3 Connect power cord with Wago connector as outlined on the left See P6000 HW6 installation manual for detailed instruc tions 4 Each pair of endpoint and actuator should be wired in parallel as shown in the diagram below and should be connected us ing the optional P6000 MJ Mini Junction Box or crimp lugs 5 For installing a single pair of endpoint and actuat...

Page 10: ...ur specific ZEMS IS W1 model Activating the Motor Actuator with the Sensor To activate the motor actuator with the sensor simply place a target in front of the sensor A single red light will flash indicating the sensor has recognized the target If the target stays in view for eleven seconds two flashing red lights will occur This indicates that the target has been in view for the required time and...

Page 11: ...pped below minimum operating range Steps should be taken to increase the line pressure Water splashes out of fixture Supply volume is more than is necessary Adjust downward on control stop Lime accumulation on vortex or spreader holes of fixture Remove the lime build up Flush is not considered quiet Control stop is not adjusted for quiet operation Adjust the control stop for quiet operation keepin...

Page 12: ... restricted access Contact organization IT department No lights are flashing Gateway is not powered Power gateway Portal High daily use alerts Usage spiked Adjust threshold possibly move to portal area Endpoint is not appearing on portal Endpoint was not registered on plumbSMART Register device in plumbSMART Device is not communicating alert See endpoint troubleshooting See endpoint troubleshootin...

Page 13: ... 2 4 13 P6000 EUA ULF RK P6000 EUA WS1 RK P6000 EUA WS RK Control Stop Repair Kit and Parts Product No Control Stop Repair Kit for 1 and 3 4 Items 14 20 P6000 D SD Seal Seat for 1 and 3 4 Items 14 P6000 D42 Sweat Solder Connection P6000 YBA Vandal Resistent Cover Item 23 P6000 VC Repair Part Inside Part Product No Urinal Relief Valve Item 6 P6000 EU13 Closet Relief Valve Item 6 P6000 EC13 1 Valve ...

Page 14: ...r Kits Product No Outside Cover Items 8 P6200 LL Outside Cover O Ring Item 7 P6200 L12 Main Seat Item 5 P6000 S 30 Water Closet Kit 1 28 GPF Items 5 6 P6200 EC HET Water Closet Kit 1 6 GPF Items 5 6 P6200 EC WS1 Water Closet Kit 3 5 GPF Items 5 6 P6200 EC Urinal Kit 0 125 GPF Items 5 6 P6200 EU ULF Urinal Kit 1 0 GPF Items 5 6 P6200 EU WS1 Urinal Kit 1 5 GPF Items 5 6 P6200 EU Adjustable Tailpiece...

Page 15: ...This Page Intentionally Left Blank ...

Page 16: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev B Date 07 29 20 C N No 142895 Prod Dwg No FV696 ...

Reviews: