background image

FV794 Rev. A   05/21/21

Page 9

    

Z6950-XL-S, Z6955-XL-S & Z6950-XL-IM-S Parts List

18

19

20

21

6

Description

Product No.

Z6950

 Spout Assembly with Sensor, Item 1A

P6950-XL-S-1

Z6955 Spout Assembly with Sensor, Item 

1B

P6955-XL-S-1

Z6950-IM Spout Assembly with Sensor, Item 

1C

P6950-XL-S-IM-1

Spout shank base for Z6950/Z6955-XL, Item 2A P6950-XL-B
Spout shank base for Z6950-XL-IM, Item 2

B

P6900-XL-IM-B

Z6950 Spout Base Gasket 

, Item 3A

P6950-XL-42

Z6955 Spout Base Gasket 

, Item 3B

P6950-XL-44

Z6950-IM Spout Base Gasket , Item 3

C

P6950-XL-IM-43

Mounting Kit, Item 4

P6900-43

Widespread Mounting Kit, Item 5

P6912-43M

Hydrogenerator Assembly, 

Item 6

P6900-HYD

Electronics Box with Solenoid - Z6950/55-XL,  

Item 7A

P6950-XL-B-L-V2

Electronics Box with Solenoid - Z6950-XL-IM,  

Item 7B

P6950-XL-IM-B-L-V2

-CWB Pigtail, Item 8

P6900-CWB

Stainless Supply Hoses (XL), Item 9

P6900-SH

Single Stainless Steel Hose (XL), Item 10

P6900-SSH

4” Cast Cover Plate w/Gasket, Item 11 

P6950-CP4

Description

Product No.

8” Cast Cover Plate w/Gasket, Item 12

P6950-CP8

Z6950 Sensor Assembly, Item 13

P6950-XL-EL

Sensor Inline Connector, Item 14

P6950-XL-DC

IM Solenoid Y Connector, Item 15

P6950-XL-YC

Optional Plug-in Power Converter, Item 16

P6900-ACA

-HW6 Power Supply, Item 17

P6900-HW6

Filter Kit, Item 18

P6900-120BC

Filter Screen, Item 19

P6900-MV-7

Mixing Valve with Filter, Item 20

P6900-XL-MV

Composite Mixing Valve Adapter,  Item 21

P6900-MV-ADAP

Mixing Tee w/Filters and Back Checks, Item 22

P6900-XL-MT

Y Pipe Adapter for Z6950-XL-IM, Item 23

P6950-XL-Y

Mixing Handle for Z6950-XL-IM, Item 24

P6950-XL-H

Mixing Handle Plug/Cap for Z6950-XL-IM, Item 

25

P6950-XL-C

Handle O-ring and Handle Screw for Z6950-XL-

IM, Item 26

P6950-XL-OS

1B

2A

2A

1A

3A

3C

4

22

1C

2B

3B

4

4

5

6

7B

7A

7A

interconnect output terminations.

electric shock - Do not

To reduce risk of fire or

WARNING:

RISK OF ELECTRIC SHOCK DRY LOCATION USE ONLY

CAUTION:

BLUE (-)

GREEN/YELLOW

FRAME/SAFETY GROUND

P6000-HW6 WIRING

  IN

VAC

(LINE)

BLACK

(NEUTRAL)

WHITE

RED (+)

instructioin manual"

only and see details in

"Use Copper conductor

O/P : +7.6VDC, 2A max load

I/P : 100-240VAC/390mA@ 50/60Hz

MODEL NO : P6000-HW6

PART NO : 200404001

REGULATED POWER SUPPLY

}

8

9

10

11

12

13

14

15

16

17

7A

23

24

25

26

26

26

Summary of Contents for HYDRO-X Power Serio Series

Page 1: ...ury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assume all risk and liability whatever in connection therewith Where permitted by law the implied warranty of m...

Page 2: ...This Page Intentionally Left Blank ...

Page 3: ...se Gasket Base Gasket Spout Assembly Aerator and Key Shank Mounting Kit Shank Mounting Kit Electronics Box with Solenoid Valve Electronics Box with Solenoid Valve Electronics Box with Solenoid Valve Aerator and Key Shank Mounting Kit Base Gasket Spout Assembly Filter Filter Filter Filter Batteries Batteries Batteries Widespread Mounting Kit Mixing Yoke Sensor Inline Connector Sensor Inline Connect...

Page 4: ...the product is installed and conforms to all plumbing codes and ordinances Do not convert or modify this Zurn product yourself All warranties will be voided Water supply lines must be sized according to building designer in order to provide adequate water supply for each fixture Flush all water lines prior to making connections Prior to Installation Before installing your Zurn Serio Series Faucet ...

Page 5: ...ream of electronics module B and filter C to bottom of electronics module Sensor cable should not pass through plastic mounting washer NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may result in debris clogging the...

Page 6: ...erminals on HW6 unit the BLACK WITH DASHED MARKINGS should be connected to the Positive terminal and the SOLID BLACK wire should be connected to the Negative terminal BLUE GREEN YELLOW FRAME SAFETY GROUND P6000 HW6 WIRING IN VAC LINE BLACK NEUTRAL WHITE RED INLINE CONNECTOR CWB HW6 ACA MJ unit sold separately Note Do not connect more than 8 solenoids to a single transformer BLUE GREEN YELLOW FRAME...

Page 7: ...e connection is made do not engage the sensor until its self calibration is complete The sensor s self calibration is complete once the faucet stops flowing water The sensor s self calibration can take up to one 1 minute after the connection is made 2 5 Tighten electronics module assembly with hydrogenerator to shank and connect water line s 2 5 a For IM assembly tighten mixing yoke with electroni...

Page 8: ... used for varied sink and environmental conditions The factory default setting should be ideal for most general applications However sensor performance can be optimized to adjust for unusual sink finish material shape or unusually bright or dark lighting conditions Switch 7 controls the sensitivity On default is normal sensitivity for most sinks providing max range Off set the sensor to a lower se...

Page 9: ... page switches 7 and 8 Direct sunlight into bowl may make the unit inoperable Do not allow direct sunlight into bowl Faucet does not activate after initial installation Sensor may not have had enough time to calibrate prior to a user or target trying to initiate activation Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables then wait until the water stops f...

Page 10: ...ent is between the 2 holes Press down and turn clockwise Use hex wrench to back set screw out to secure spout To reinstall faucet first drop sensor cable of new spout through the front of the base Lower spout onto base inserting base nipple into spout port To replace spout body you must first turn water off then remove spout with sensor cable Note location of set screw and spring lock Spout Replac...

Page 11: ...ket Item 12 P6950 CP8 Z6950 Sensor Assembly Item 13 P6950 XL EL Sensor Inline Connector Item 14 P6950 XL DC IM Solenoid Y Connector Item 15 P6950 XL YC Optional Plug in Power Converter Item 16 P6900 ACA HW6 Power Supply Item 17 P6900 HW6 Filter Kit Item 18 P6900 120BC Filter Screen Item 19 P6900 MV 7 Mixing Valve with Filter Item 20 P6900 XL MV Composite Mixing Valve Adapter Item 21 P6900 MV ADAP ...

Page 12: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 05 21 21 C N No 143760 Prod Dwg No FV794 ...

Reviews: