background image

Details

Notes

•  

All parameters if not specially mentioned are measured at 120VAC input, rated load and ambient temperature of 25°C.

•  

To extend the life of the driver keep the load below 90%.

•  

Load on the driver should be within 10%-100%.

•  

Loading on the AC dimmer should not be below 40% in order to extend the life of the dimmer.

ZRK-EMLV2-200W-XXDC-J

IP66 (indoor and outdoor)

110 - 277 VAC

12VDC or 24VDC

12V: 16.66A 24V: 8.3A

200W (100W per Output Power Wire)

47 ~ 63Hz

0.98 (fully loaded)

12V: 86% 24V: 86%

2.3A @ 110VAC

<0.50mA

Shuts down output voltage, recovers 
after faulty condition is removed

≤120%

212°F ± 18°F (100°C ± 10°C)  Shuts 
down output voltage, recovers after 
faulty condition is removed

-40°F ~ 140°F (-40°C ~ 60°C)

SKU:
Ingress Protection:
Input Voltage:
Output Voltage:
Rated Current:
Rated Power:
Frequency Range:
Power Factor:
Efficiency (Typ.):
AC Current (Max.):
Leakage Current:
Short Circuit:

Overload Protection:
Overheat Protection:

Working Temp:

20 ~ 90%RH. Non condensing

-40°F ~ 176°F (-40°C ~ 80°C), 
10 ~ 95%RH

±0.03% /°C [32°F ~ 122°F (0 ~ 50°C)]

10 ~ 500Hz, 2G 10min./ 1 cycle, period 
for 60min. Each along X,Y,Z axes

UL (E500166), conforms to UL8750, 
certified to CSA STD.C22.2 No. 250.13

I/P-O/P:1880VAC

I/P-O/P:100MΩ/500VDC/25°C/70%RH

FCC Part 15B

4.91lb (2.23kg) with junction box /       
3.30lb (1.5kg) without junction box

H: 

10 1/8

” (256mm) W: 3 1/8“ (78mm)       

D: 1 7/8” (47mm)

400Hz

7 years

Working Humidity:
Storage Temp. and 

Humidity:
Temp. Coefficient:
Vibration:

Certifications:

Withstand Voltage:
Isolation Resistance:
EMC Emission:
Weight:

Dimensions:

PWM Frequency:
Warranty:

V.2019.08.29

ZRK-EMLV2-200W-XXDC

2

page

support@FlexfireLEDs.com

925-273-9080 opt 2

User Guide 

 

ZURIK

®

 EMLV LED Driver 200W

Summary of Contents for EMLV

Page 1: ... required for installations inside walls and building structures Consult a qualified electrician Do not install in wet locations Install only in dry or damp locations Only use with compatible dimmable LED fixtures Dimmer switches have minimum load requirements Review the specifications of the compatible dimmer Modifying or disassembling this product beyond these instructions will void the product ...

Page 2: ...ss Protection Input Voltage Output Voltage Rated Current Rated Power Frequency Range Power Factor Efficiency Typ AC Current Max Leakage Current Short Circuit Overload Protection Overheat Protection Working Temp 20 90 RH Non condensing 40 F 176 F 40 C 80 C 10 95 RH 0 03 C 32 F 122 F 0 50 C 10 500Hz 2G 10min 1 cycle period for 60min Each along X Y Z axes UL E500166 conforms to UL8750 certified to CSA ...

Page 3: ... Driver Wire connectors terminal block electrical tape crimp connector etc 2 wire stranded low voltage wire D C A C To extend the power supply s life refer to the Derating Curve above and derate according to the ambient temperature DERATING CURVE YOU LL NEED V 2019 08 29 ZRK EMLV2 200W XXDC 3 page support FlexfireLEDs com 925 273 9080 opt 2 User Guide ZURIK EMLV LED Driver 200W ...

Page 4: ...ls When using a 3 pole dimmer as a single pole make sure to cap the additional line and connect the rest of the wiring as recommended by the dimmer instructions Find our list of compatible dimmers below Connect the driver s Output Power negative wire to the channel on the LED strip Connect the positive wire to the channel Always pre test your LED setup prior to permanent installation This will ens...

Page 5: ...0W MSCELV 600M 100 130V 0 100 Maestro Reverse Phase 600W MRF2 6ELV 120 100 130V 0 100 Maestro Reverse Phase 600W MIR 600M 100 130V 2 100 Maestro IR Remote Ctrl Forward Phase 600W NTF 10 277 277V 1000W 13 100 Nova T Forward Phase TGCL 153PR WH 100 130V 0 100 Ariadni Toggler Forward Phase 150W TGCL 153PH WH 100 130V 0 100 Ariadni Toggler Forward Phase 150W TG 600PR WH 100 130V 0 100 Ariadni Toggler ...

Page 6: ...r Reverse Phase Dimming Range Input Voltage Model Number Dimmer Brand Wattage VPI06 1LZ 100 130V 15 100 Forward Phase 600W Forward Phase TTI06 1LZ 100 130V 1 100 600W Forward Phase IPL06 100 130V 15 100 150W Forward Phase DZ6HD 100 130V 17 100 600W Forward Phase 6674 100 130V 16 100 Leviton 150W Forward Phase 6672 100 130V 20 100 150W Forward Phase TBL03 100 130V 15 100 150W Forward Phase 6602 100...

Page 7: ...ower Supply LED Output L N Input Zurik EMLV Dimmable Power Supply L Output L N Input Zurik EMLV Dimmable Power Supply L N AC Input AC Dimmer Zurik EMLV Dimmable Power Supply Output LED L Using a single driver Using multiple drivers WIRING DIAGRAMS V 2019 08 29 ZRK EMLV2 200W XXDC 7 page support FlexfireLEDs com 925 273 9080 opt 2 User Guide ZURIK EMLV LED Driver 200W ...

Page 8: ...r is on the compatible dimmer list Make sure all the connections solderless connectors solder joints terminal blocks and spliced wires are secure and making correct contact Make sure the power requirements are being met 100 277VAC input and 12 24VDC output depending on the driver check these with a multimeter If the driver isn t providing the adequate voltage ensure proper size gauge wire is insta...

Page 9: ...s or force majeure incidences Damage caused by a vehicle or other accident Damage caused when transporting the item Damage to any products that were modified by the user used for purposes other than as intended or directed or connected to LED systems or components not purchased from Flexfire LEDs Products that have been subjected to misuse mishandling misapplication or accident Products used in co...

Reviews: