background image

INSTALLAZIONE / INSTALLATION 

OPERATING INSTRUCTIONS:

 

The lowest handle has a degree scale and it controls the thermostatic element. 
The button on the handle blocks the maximum rotation at 49°C (120°F) for safety and anti scald purposes. 
 

ADJUST TEMPERATURE LIMIT STOP: 

To increase or decrease the maximum temperature of hot water proceed as follows: 

• 

By keeping the temperature handle upward, take off the cap and the fixing screw of the thermosta)c 
handle then the handle itself 

• 

Unlock the white stop sleeve taking it out 

• 

Turn the white stop sleeve clockwise (for colder water) or counter clockwise (for ho,er water) and lock 
it again pushing it 

• 

Reassemble the thermostatic handle 

 

SERVICE INSTRUCTIONS:

 

The thermosta)c mixer is set at the factory at the temperature of 38°C (100°F). 
If the temperature, of the mixed water, should not result at 38°C (100°F), proceed as follows: 

• 

By keeping the temperature handle upward, take off the cap and the fixing screw of the thermosta)c 
handle then the handle itself 

• 

Remove the white stop sleeve 

• 

Turn the thermosta)c cartridge pin clockwise (for colder water) or counter clockwise (for ho,er water) 
)ll the temperature of water of 38°C (100°F) is obtained 

• 

Reassemble the white stop sleeve as shown in the picture below 

• 

Reassemble the handle, keeping a,en)on to have the bu,on upward 

 

CONDITION OF USE: 

Product for use with shower heads rated at 9.5 L/min (2.5 gpm) or higher 