INSTALLAZIONE / INSTALLATION
OPERATING INSTRUCTIONS:
The lowest handle has a degree scale and it controls the thermostatic element.
The button on the handle blocks the maximum rotation at 49°C (120°F) for safety and anti scald purposes.
ADJUST TEMPERATURE LIMIT STOP:
To increase or decrease the maximum temperature of hot water proceed as follows:
•
By keeping the temperature handle upward, take off the cap and the fixing screw of the thermosta)c
handle then the handle itself
•
Unlock the white stop sleeve taking it out
•
Turn the white stop sleeve clockwise (for colder water) or counter clockwise (for ho,er water) and lock
it again pushing it
•
Reassemble the thermostatic handle
SERVICE INSTRUCTIONS:
The thermosta)c mixer is set at the factory at the temperature of 38°C (100°F).
If the temperature, of the mixed water, should not result at 38°C (100°F), proceed as follows:
•
By keeping the temperature handle upward, take off the cap and the fixing screw of the thermosta)c
handle then the handle itself
•
Remove the white stop sleeve
•
Turn the thermosta)c cartridge pin clockwise (for colder water) or counter clockwise (for ho,er water)
)ll the temperature of water of 38°C (100°F) is obtained
•
Reassemble the white stop sleeve as shown in the picture below
•
Reassemble the handle, keeping a,en)on to have the bu,on upward
CONDITION OF USE:
Product for use with shower heads rated at 9.5 L/min (2.5 gpm) or higher