![Zte ZXSDR R8882 L268 User Manual Download Page 53](http://html1.mh-extra.com/html/zte/zxsdr-r8882-l268/zxsdr-r8882-l268_user-manual_940284053.webp)
Chapter 4 Product Installation
4.6.4 Installing Grounding Cable
Context
The grounding cable of ZXSDR R8882 L268 is made up of strands of flame-retardant wire.
The cross sectional area of grounding cable is 25 mm
2
. Copper lugs are crimped at both
ends of the grounding cable, as shown in
.
Figure 4-35 Structure of Grounding Cable
Steps
1.
Cover and fix a copper lug on the a grounding bolt of the ZXSDR R8882 L268 cabinet.
2.
Connect the other copper lug to the earth-networking copper bar and fix it with bolts,
as shown in
.
Figure 4-36 Grounding Copper Bar
3.
Attach the label on the grounding cable.
4.
Measure the grounding resistance and make sure it is less than 5 ohms.
– End of Steps –
4.6.5 Installing Fiber Between eBBU and eRRU
Prerequisite
The ZXSDR R8882 L268 unit has been installed and securely fastened.
4-29
SJ-20110104194923-001|2011-01-19(R1.0)
ZTE Proprietary and Confidential