background image

ZXMBW E9230

Compact Base Station (outdoor)

User Manual

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: [email protected]

Summary of Contents for ZXMBW E9230

Page 1: ...tion outdoor User Manual ZTE CORPORATION ZTE Plaza Keji Road South Hi Tech Industrial Park Nanshan District Shenzhen P R China 518057 Tel 86 755 26771900 Fax 86 755 26770801 URL http ensupport zte com cn E mail support zte com cn ...

Page 2: ...itness for a particular purpose title or non in fringement ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document Except as expressly provided in any written licens...

Page 3: ...ck Parameter 9 Environmental Indices 9 Compliance Standards 10 Protocol Interface Description 10 ASN Network Reference Model 10 Protocol Interfaces 11 R1 Interface 12 R6 Interface 14 Hardware Description 19 Cabinet Structure 19 Hardware Modules 21 MTRW Module 21 WDPA Module 21 WRFE Module 22 WRPM Module 23 Equipment Installation 25 Components to be Installed 25 Installation Flow 25 Installation Pr...

Page 4: ...duction 30 Installing a Wall Mount Cabinet 34 Installing a Pole Mount Cabinet 39 Installing External Cables 47 Installing Power Cable 47 Installing Grounding Cable 49 Installing RF Jumper 50 Installing Antenna 51 Installing Feeder Grounding Kit 54 Performing Outdoor connector Waterproof Processing 55 VSWR Test 60 Cabinet Installation Check 60 Cabinet Installation Check 60 On site Environment Inspe...

Page 5: ... the following chapters Chapter Summary Chapter 1 Product Overview Introduces the position functions principles external and internal interfaces applications and technical indices of the ZXMBW E9230 Chapter 2 Hardware Description Describes the cabinet structure hardware modules antenna feeder system and external cables of the ZXMBW E9230 Chapter 3 Equipment Installation Describes the installation ...

Page 6: ...ZXMBW E9230 User Manual This page is intentionally blank ii Confidential and Proprietary Information of ZTE CORPORATION ...

Page 7: ...tion 10 ZXMBW E9230 Position in the Network ZXMBW E9230 is located in the radio access layer of WiMAX net works and used to provide broadband radio access for users in outdoor hot and blind spots suburbs rural areas railways and highways Figure 1 shows the position of the ZXMBW E9230 in the WiMAX network FIGURE 1 ZXMBW E9230 POSITION IN THE NETWORK Table 1 describes the meanings of these NEs Confi...

Page 8: ...ward automatic calibration and manual calibra tion Reverse Signal Processing Receives reverse RF WiMAX signals from space and performs band pass filtering low noise amplification RF RF mixing and digital down conversion on these signals and then sends them to the baseband OFDMA modulation and MAC layer processing Afterwards the baseband sends these signals to AGW through the R6 interface for inter...

Page 9: ...ions of the ZXMBW E9230 cabinet are 370mm W 320mm D 165mm H Figure 2 shows the ZXMBW E9230 ap pearance FIGURE 2 ZXMBW E9230 APPEARANCE Fundamental Principle The ZXMBW E9230 implements the radio access function for out door coverage systems It provides the following functions Confidential and Proprietary Information of ZTE CORPORATION 3 ...

Page 10: ...vice The core network sends IP packets to the ZXMBW E9230 through the transmission network After receiving these pack ets the MTRX unit of the ZXMBW E9230 disassembles them and then sends to the baseband process unit for encoding and modulation Afterwards these IP packets are sent to the RF process unit for up conversion and power amplification before being transmitted to ATs Reverse service The s...

Page 11: ...ctrically tuned an tenna interface 8 core aerial connec tor 1 1 2 and 3 Gigabit Ethernet elec trical interface Electrical interface connector assembly 3 4 Monitoring mainte nance cascade inter face 37 core aerial con nector assembly 1 5 DC power interface Power connector as sembly 1 6 and 7 RF antenna feeder in terface N female 2 8 GPS antenna inter face TNC female 1 9 Gigabit Ethernet opti cal in...

Page 12: ...The ZXMBW E9230 supports multiple networking applications ZXMBW E9230 Independent Networking Application Figure 5 illustrates the ZXMBW E9230 independent networking ap plication FIGURE 5 INDEPENDENT NETWORKING APPLICATION Star Networking Application Figure 6 illustrates the ZXMBW E9230 R6 interface star networking application FIGURE 6 ZXMBW E9230 STAR NETWORKING APPLICATION Daisy Networking Applic...

Page 13: ...dex Description Dimension 370mm W 320mm D 165mm H Weight 15 kg Power Supply 48V DC Temperature of working environ ment 40 55 Humidity of work ing environment Relative humidity range 5 95 Overall power con sumption 200 W Protection level IP65 Overall size 20 litres Overall power of power supply 200 W Heat dissipation Self cooling Confidential and Proprietary Information of ZTE CORPORATION 7 ...

Page 14: ...lectrical interface Overall noise No noise Maintenance It supports remote upgrading It supports the local OMC and Debug interface Environmental protection It meets the Restriction of the Use of certain Hazardous Substances in Electrical and Electronic Equipment ROHS and Waste Electrical and Electronic Equipment Directive WEEE of the European Union Heat dissipation Self cooling Followed standards I...

Page 15: ... Animals Anti rodent but not anti termites Chemical material condition 4C2 Salt fog Salt spray proofing Sand mg m3 1000 Dust floating mg m3 15 Mechanical ma terial conditions 4S3 Dust sinking mg m2 d 1000 Temperature 40 55 Relative humidity 5 95 Temperature change rate min 0 5 Pressure kPa 70 106 Solar radiation W m2 1120 Dewdrop It meets the dewdrop requirement Precipitation rain snow and hail It...

Page 16: ... 16 Air Interface for Fixed and Mobile Broadband Wireless Access Systems WiMAX ForumTM Mobile Radio Conformance Tests MRCT WiMAX ForumTM Mobile Protocol Implementation Conformance Statement PICS Proforma WiMAX ForumTM Mobile System Profile Protocol Interface Description ASN Network Reference Model Figure 8 illustrates the ASN network reference model formulated by WiMAX NWG 10 Confidential and Prop...

Page 17: ...d the core network R4 Interface between ASNs or AGWs It implements handoff related signaling and data channel that is set up to maintain data consistency during handoff R6 Interface between AGW and BTS R7 Optional Internal interface of AGW It divides AGW into the policy decision part and the policy realization part Protocol Interfaces ZXMBW E9230 supports R1 interface and R6 interface as shown in ...

Page 18: ...nnel between the AGW and the BS It is used to differentiate the traffic flows with different Quality of Service QoS levels Control pane Control plane supports the tunnel management Authen tication Authorization Accounting AAA and Radio Re source Management RRM functions R1 Interface Short Description R1 interface is the interface between the BS and the MS contain ing MAC layer physical layer and r...

Page 19: ... into MAC SDU and transmits the data to MAC CPS through MAC SAP The sub layer classifies external Service Data Units SDUs and associates them with proper SFIDs and CIDs It supports the payload head compression function and pro vides various service specific convergence sub layer specifications for different external protocol interfaces MAC CPS sub layer The MAC CPS sub layer does not resolve the p...

Page 20: ... plane data is borne over the encapsulation tunnel protocol UDP bears R6 signaling Generic Routing Encapsulation GRE Multiple Protocol Label Switching MPLS and Virtual Local Area Network VLAN bears R6 data The ASN GW terminates the R6 tunnel from the BS The R6 tunnel can adopt various encapsulation technologies such as GRE MPLS and VLAN and different tunnel granularities are allowed The R6 data pa...

Page 21: ...d to the message If the message is not related to any specific MS all bits of this field are set to 0 Reserved 32 reserved bits which are set to 0 Transaction ID Transaction ID If it is 0 the message should be discarded Reserved Reserved bit which is set to 0 Destination Identifier TLV Type Length Value Length variable destination entity identifier For example the destination to which the message ...

Page 22: ...in Source Identifier TLV and Destination Identifier TLV R Resets the next expected Transaction ID Control Plane Protocol Stack Figure 13 illustrates the structure of the R6 control plane protocol stack FIGURE 13 R6 CONTROL PLANE PROTOCOL STACK A logical connectivity between L2 L3 of two control plane protocol stacks enables communication between the two functional entities The encapsulation of IP ...

Page 23: ...Chapter 1 Product Overview Packet access 10M 100M 1000 MBps FE electrical port 1000 MBps Ethernet optical port Confidential and Proprietary Information of ZTE CORPORATION 17 ...

Page 24: ...ZXMBW E9230 User Manual This page is intentionally blank 18 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 25: ...Contents Cabinet Structure 19 Hardware Modules 21 MTRW Module 21 WDPA Module 21 WRFE Module 22 WRPM Module 23 Cabinet Structure Figure 14 shows the structure of the ZXMBW E9230 cabinet Confidential and Proprietary Information of ZTE CORPORATION 19 ...

Page 26: ...9230 User Manual FIGURE 14 ZXMBW E9230 CABINET STRUCTURE Note Do not open the ZXMBW E9230 cabinet Contact ZTE engineers to open it for maintenance 20 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 27: ... DPD processing and power amplifying of base band signals as well as energy conversion between the electric field and the magnetic field 4 Reverse functions of the RF channel including receiving am plifying and down converting of RF signals 5 Clock processing functions including GPS signal receiving and clock processing 6 Cascading and convergence of the R6 daisy chains and stars of the active sta...

Page 28: ...h alarms as temperature high low power and standing wave alarms Low Noise Amplifier LNA amplifies the received signals WRFE Module The WRFE module is the WiMAX RF Front End Filter module of ZXMBW E9230 Function The WRFE module provides the following functions Provides the RF interface to transfer RF signals to the antenna Filters RF signals Provides RF unit lightning proof function Isolates uplink...

Page 29: ... module FIGURE 16 WRPM WORKING PRINCIPLE DC The WRPM module consists of EMI filtering unit protection unit DC DC conversion unit and alarm monitoring unit The functions of the units are described as follows The EMI filtering unit provides the filtering function The protection unit provides over voltage or under voltage protection The DC DC conversion unit implements power supply conver sion The al...

Page 30: ...ZXMBW E9230 User Manual This page is intentionally blank 24 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 31: ...on Check 60 Power on 61 Components to be Installed Installation components include 1 ZXMBW E9230 cabinet Note The cables inside the ZXMBW E9230 cabinet and function mod ules have been installed before shipment 2 External cable 3 Main antenna feeder system including antenna feeder and main feeder Installation Flow Figure 17 illustrates the installation flow of ZXMBW E9230 Confidential and Proprieta...

Page 32: ...stallation Precautions ZXMBW E9230 technical personnel must check equipment running environment before installation Moreover they must know about communication networking data configuration status of equip 26 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 33: ...tallation Preparation Installation Environment Check Before installing equipment check installation environment ac cording to every items of requirements in Environment Acceptance Report Installation Position Requirements The installation position of ZXMBW E9230 must accord with the requirements of engineering designs The detailed requirements are described as follows Locate away from areas that a...

Page 34: ... ZXMBW E9230 cabinet TABLE 12 POWER SUPPLY REQUIREMENTS Category Requirement DC 36 V 60 V DC Caution Make sure that the power polarities are consistent during installa tion otherwise the equipment may be damaged Other Preparation 1 Check whether relevant devices or components accord with the requirements of engineering design drawing 2 Wrap cable connectors with insulating tapes before laying powe...

Page 35: ...rcussion drill Auxiliary and sample bits One vacuum cleaner Concrete drilling tools Power socket two phase and three phase socket with current capacity greater than 15 A Cross screwdrivers 4 6 and 8 each Flathead screwdrivers 4 6 and 8 each Adjustable wrenches 6 8 10 and 12 Dual purpose spanners 17 and 19 each One set of socket wrench 5 kg 11 lb nail hammer One 300 W iron One 40 W iron Solder wire...

Page 36: ...th several saw blades One pair of sharp nose pliers 8 One pair of diagonal pliers 8 One pair of slip joint pliers 8 One pair of vices 8 Clamp tools Crowbar Chain wheel Rope Ladder Auxiliary tools Forklift Installing Cabinets Installation Mode Introduction The installation modes of ZXMBW E9230 involve wall mount in stallation and pole mount installation based on different installa tion environments...

Page 37: ...lation The pole mount installation is classified into three scenarios 1 Pole mount installation with one ZXMBW E9230 cabinet as shown in Figure 19 2 Pole mount installation with two ZXMBW E9230 cabinets as shown in Figure 20 3 Pole mount installation with three ZXMBW E9230 cabinets as shown in Figure 21 Confidential and Proprietary Information of ZTE CORPORATION 31 ...

Page 38: ...ZXMBW E9230 User Manual FIGURE 19 ONE ZXMBW E9230 POLE MOUNT INSTALLATION 32 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 39: ...LLATION FIGURE 21 THREE ZXMBW E9230 POLE MOUNT INSTALLATION Note For outdoor installation install a sun shield The sun shield is shown in Figure 22 For indoor installation there is no need to install the sun shield Confidential and Proprietary Information of ZTE CORPORATION 33 ...

Page 40: ...ngineering design drawing Then mark the hole positions on the wall with a hole design tem plate The hole template is shown in Figure 23 FIGURE 23 HOLING TEMPLATE UNIT MM 2 Install M8 80 expansion bolts i Use an electrical percussion drill φ10 to drill holes at these positions Use a vacuum cleaner to clear dust while drilling 34 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 41: ...mmer to strike the expansion bolt into the hole Screw down the nut to make the expansion tube expanded enough and then remove the nut as shown in Figure 24 FIGURE 24 INSTALLING M8 80 EXPANSION BOLT 3 Install a supporting panel on the wall Fix the supporting panel on the wall with bolts as shown in Figure 25 Confidential and Proprietary Information of ZTE CORPORATION 35 ...

Page 42: ...d 3 Supporting panel 4 Insulation flange 5 Plain washers 6 Spring mat 7 M8 nut 4 Install the ZXMBW E9230 cabinet Mount the ZXMBW E9230 cabinet onto the supporting panel and fasten them with four M6 20 hexagon socket cap screws as shown in Figure 26 36 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 43: ... CABINET 1 Supporting panel 2 M6 20 Screw 3 Retaining board 5 Install a sun shield optional i Assemble the sun shield with M5 16 cross recessed small pan head screws as shown in Figure 27 and Figure 28 Confidential and Proprietary Information of ZTE CORPORATION 37 ...

Page 44: ...small pan head screw 2 Sun shield 3 Reinforce rob 4 Bracket ii Screw off two M6 screws at both sides of ZXMBW E9230 cabinet and fix the sun shield to the supporting panel iii Mount the sun shield to the cabinet with two M6 20 hexagon screws and four M5 16 cross recessed small pan head combined screws as shown in Figure 29 38 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 45: ...D OF STEPS Installing a Pole Mount Cabinet Steps 1 Mount supporting clip or fixing bracket assemblies For installing one or two ZXMBW E9230 cabinets pre install the clips to the pole as shown in Figure 30 For installing three ZXMBW E9230 cabinets first pre install two sets of fixing brackets to the pole as shown in Figure 31 Confidential and Proprietary Information of ZTE CORPORATION 39 ...

Page 46: ... installing two or three ZXMBW E9230 cabinets it is recommended to use the pole with 100 to 120 mm diameter ii There are two kinds of bolt length 80 mm 3 15 inches and 120 mm 4 72 inches are available and bolt of length 120 mm 5 12 inches for pole diameter of 90 mm 3 54 inches 120 mm 4 72 inches Use the bolt of length 80 mm 3 15 inches for pole diameter of 60 mm 2 36 inches 90 mm 3 54 inches Use t...

Page 47: ...t the supporting panel assemblies For installing one ZXMBW E9230 cabinet the supporting panel is installed as shown in Figure 32 For installing two ZXMBW E9230 cabinets the supporting panel is installed as shown in Figure 33 For installing three ZXMBW E9230 cabinets the supporting panel is installed as shown in Figure 34 Confidential and Proprietary Information of ZTE CORPORATION 41 ...

Page 48: ...ead bolt 2 Spring washer 8 3 Big washer 8 4 Insulating flange 5 Supporting panel 6 Insulating plate 7 Long clip 8 M10 120 or M10 80 hexagon head bolt 9 Pole 10 Flat washer 10 11 Spring washer 10 12 M8 nut 13 Long clip 42 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 49: ...ng clip FIGURE 34 MOUNTING SUPPORTING PANEL 3 1 Fixing bracket 2 Insulating plate 3 Supporting panel 4 Insulating flange 5 Big washer 8 6 Spring washer 8 7 M8 40 hexagon head bolt 3 Mount the ZXMBW E9230 cabinet Hold the ZXMBW E9230 cabinet align and fix its beam to the corresponding block plate on the supporting panel Use M6 20 Confidential and Proprietary Information of ZTE CORPORATION 43 ...

Page 50: ...orting panel as shown in Figure 35 Figure 36 and Figure 37 FIGURE 35 MOUNTING ONE ZXMBW E9230 CABINET 1 M6 20 hexagon head screw 2 Block plate on the supporting panel 3 Beam on the ZXMBW E9230 cabinet 44 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 51: ...E9230 cabinet FIGURE 37 MOUNTING THREE ZXMBW E9230 CABINETS 1 Beam on the ZXMBW E9230 cabinet 2 M6 20 hexagon head screw 3 Supporting panel 4 Install a sun shield optional i Assemble the sun shield with M5 16 cross recessed small pan head screws as shown in Figure 38 and Figure 39 Confidential and Proprietary Information of ZTE CORPORATION 45 ...

Page 52: ...small pan head screw 2 Sun shield 3 Reinforce rob 4 Bracket ii Screw off two M6 screws at both sides of ZXMBW E9230 cabinet and fix the sun shield to the supporting panel iii Mount the sun shield to the cabinet with two M6 20 hexagon screws and four M5 16 cross recessed small pan head combined screws as shown in Figure 40 46 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 53: ... pan head screw 3 Buckling position 4 M6 20 hexagon screw 5 ZXMBW E9230 cabinet END OF STEPS Installing External Cables Installing Power Cable Context ZXMBW E9230 cabinet uses 48 V DC for power supply Table 14 describes power cable configuration Confidential and Proprietary Information of ZTE CORPORATION 47 ...

Page 54: ...ased on the engineering survey The structure of DC power cable is as shown in Figure 41 FIGURE 41 DC POWER CABLE STRUCTURE 2 Table 15 describes core color and definition inside the DC power cable TABLE 15 DC POWER CABLE INNER CORE COLOR AND DEFINITION Color Definition Blue 48V Black 48V GND Note i Using two core cable the blue core stands for 48V and the black core stands for 48V GND ii For four c...

Page 55: ... OF STEPS Installing Grounding Cable Prerequisites 1 Install the ZXMBW E9230 cabinet 2 Install the grounding copper bar 3 Measure the grounding resistance 10Ω Context 1 The grounding cable is made of fireproof multi strand conduc tors It is in yellow and green and its cross sectional area is 16mm2 as shown in Figure 42 FIGURE 42 GROUNDING CABLE Steps 1 Copper lugs are crimped at both ends of the g...

Page 56: ...cable to the copper bar Finally fix them with a bolt FIGURE 44 COPPER BAR OF GROUND NET 4 Cover antirust lacquer around the bolt 5 Affix a label on the grounding cable END OF STEPS Installing RF Jumper Context RF jumper is used to connect the main feeder and the antenna feeder interface of ZXMBW E9230 Its installation is supposed to be after that of the main feeder The RF jumper adopts the finishe...

Page 57: ... 1 Antenna height Determined by the network plan 2 Antenna azimuth Determined by the network plan 3 Antenna pitch angle Determined by the network plan usually adjustable between 0 to 10 4 Antenna directional angle Determined by the antenna az imuth The directional angles of the two antennas of one sector must be the same The antenna installation position must be in accordance with project design I...

Page 58: ...lightning protection system onto the antenna pole Make sure that the lightning rod is well grounded Note This section introduces the installation process of directional an tenna briefly Refer to the installation guide delivered with the antenna for detailed installation steps Steps 1 Assemble parts of directional antenna Firstly assemble fastener C onto the upper and lower ends of antenna as shown...

Page 59: ...ring design drawing ii Turn the antenna slightly to adjust it s face direction as shown in Figure 47 At the same time measure the direc tion of the antenna with a compass until the error comes within the engineering design requirements generally not more than 5 iii After adjusting the azimuth of the antenna tighten the fas tener A 4 Adjust the antenna s downtilt i Adjust the downtilt of the measur...

Page 60: ...1 Peel off 7 8 sheath according to size of grounding clip at the positions Figure 49 illustrates structure of grounding kit FIGURE 49 GROUNDING KIT STRUCTURE 1 Grounding terminal 2 Grounding cable 3 Feeder cable 4 Grounding spring lock 5 Feeder external copper core 6 Grounding cable copper piece 2 Lay the grounding cable facing to the ground network Avoid bending or folding And keep the included a...

Page 61: ...ound kit and feeder The methods are listed as follows i First wrap waterproof self adhesive tape and then wrap PVC adhesive tape ii For waterproof self adhesive tape first wrap from lower to upper layer by layer then wrap from upper to lower layer by layer and finally wrap from lower to upper layer by layer During wrapping the former layer covers a half of the next layer 6 The grounding terminal o...

Page 62: ... Steps 1 Wrap a layer of PVC insulating tape i Clean out dust and stain on the feeder connector or feeder grounding kit ii As shown in Figure 53 wrap the feeder with the PVC insu lating tape in an overlapping way from lower to upper and the upper adhesive tape should cover a half of the lower adhesive tape The extended width of adhesive tape is not over 1 2 longer than the former width or else it ...

Page 63: ...gth Bind the feeder in an overlapping way from lower to upper and the upper adhesive tape should cover a half of the lower adhesive tape as shown in Figure 54 FIGURE 54 WRAPPING THREE LAYERS OF WATER INSULATING TAPE THE FIRST LAYER Note The wrapping direction should be towards the direction of connector screwed down Prohibit wrapping in a reverse direction iii While wrapping to the 20 50 mm positi...

Page 64: ...nsulating tape Two ends of PVC insulating tape must be 20mm longer than the upper layer of waterproof insulating tape Bind the feeder in an overlapping way from lower to upper and the upper adhesive tape should cover a half of the lower adhesive tape as shown in Figure 57 Repeat it for twice and the sequence respectively is from upper to lower as shown in Figure 58 and from lower to upper as shown...

Page 65: ...ER FIGURE 58 WRAPPING THREE LAYERS OF PVC INSULATING TAPE THE SECOND LAYER FIGURE 59 WRAPPING THREE LAYERS OF PVC INSULATING TAPE THE THIRD LAYER 4 After finishing wrapping fasten two wrapped ends with black fasteners as shown in Figure 60 Confidential and Proprietary Information of ZTE CORPORATION 59 ...

Page 66: ... intact Ensure that the connection between all parts are proper Check whether the antenna feeder installation is perfect END OF STEPS Cabinet Installation Check Cabinet Installation Check 1 Ensure that cabinet installation location complies with the en gineering design drawing 2 Erect cabinet firmly so as to resist an earthquake measuring up to 7 0 on Richter scale 3 Ensure that horizontal and ver...

Page 67: ... left Make sure that the installation site is neat and tidy Power on Prerequisites 1 Power supply voltage accords with ZXMBW E9230 require ments 2 Connect the cabinet power and grounding cable properly 3 The power switch is disconnected Steps 1 There is no power switch located at the ZXMBW E9230 cabi net Therefore opening external power switches will power on ZXMBW E9230 2 During power on process ...

Page 68: ...ZXMBW E9230 User Manual This page is intentionally blank 62 Confidential and Proprietary Information of ZTE CORPORATION ...

Page 69: ...Principle DC 23 Figure 17 ZXMBW E9230 Installation Flow 26 Figure 18 ZXMBW E9230 Wall Mount Installation 31 Figure 19 One ZXMBW E9230 Pole Mount Installation 32 Figure 20 Two ZXMBW E9230 Pole Mount Installation 33 Figure 21 Three ZXMBW E9230 Pole Mount Installation 33 Figure 22 Sun Shield 34 Figure 23 Holing Template Unit mm 34 Figure 24 Installing M8 80 Expansion Bolt 35 Figure 25 Installing Supp...

Page 70: ...Downtilt Adjustment 54 Figure 49 Grounding Kit Structure 54 Figure 50 Wrapping Waterproof Adhesive Tape 55 Figure 51 Waterproof Insulating Tape 56 Figure 52 PVC Adhesive Tape 56 Figure 53 Wrapping a Layer of PVC Insulating Tape 57 Figure 54 Wrapping Three Layers of Water Insulating Tape the first layer 57 Figure 55 Wrapping Three Layers of Water Insulating Tape the second layer 58 Figure 56 Wrappi...

Page 71: ...rmat 13 Table 8 R6 Control Plane Message Field Description 15 Table 9 Flags Field Description 16 Table 10 WRFE Performance Specifications 22 Table 11 Temperature and Humidity Requirements 28 Table 12 Power Supply Requirements 28 Table 13 Tool and Meter List 29 Table 14 Power Cable Configuration 48 Table 15 DC Power Cable Inner Core Color and Definition 48 Confidential and Proprietary Information o...

Reviews: