ZXA10 S300 (V1.1) Integrated Access Service Dispatching Unit Technical Manual
38
Confidential and Proprietary Information of ZTE CORPORATION
Performance Index of Ethernet
Interface
10Base-TX interface
Table 13 describes the use scope of the 1000Base-SX
interface.
T
A B L E
1 3
−
U
S E
S
C O P E O F
1 0 0 0 B
A S E
- S X
I
N T E R F A C E
Fiber Type
Module Width @ 850 nm (minimum
full load)
(MHz
km)
Minimum Scope
(m)
62.5
μ
mMMF
160
2 ~ 220
62.5
μ
mMMF
200
2 ~ 275
50
μ
mMMF
400
2 ~ 500
50
μ
mMMF
500
2 ~ 550
Table 14 lists the optical transmitting power of the
1000Base-SX interface.
T
A B L E
1 4
−
T
R A N S M I T T I N G
O
P T I C A L
P
O W E R O F
1 0 0 0 B
A S E
- S X
I
N T E R F A C E
Item
62.5
μ
mMMF
50
μ
mMMF
Unit
Signaling rate (range)
1.25
±
100 ppm
GBd
Wavelength (
λ
?, range):
770 ~ 860
nm
Trise/Tfall (maximum, 20% ~
80%,
λ
?
>
830 nm)
0.26 ns
Trise/Tfall (maximum, 20% ~
80%,
λ
?
≤
830 nm)
0.21 ns
RMS spectral width
(maximum)
0.85 nm
Mean optical transmitting
power (maximum)
(Note) dBm
Mean optical transmitting
power (minimum)
-9.5 dBm
Mean optical transmitting
power when the transmitter is
OFF (maximum)
-30 dBm
Extinction ratio (minimum)
9
dB
RIN (maximum)
-117
dB/Hz
Coupling power ratio
(CPR)(minimum)
9
<
CPR
dB
Note: The maximum transmitting power should be the maximum receiving
power or the danger threshold specified in TEEE803.2, whichever is smaller.
Summary of Contents for ZXA10 S300
Page 4: ...This page is intentionally blank ...