Input to output isolation

Not isolated

Input voltage

20 to 35 VDC

Output voltage

13.8 VDC ± 0.1 V

Output voltage regulation

< 3%

Input current at no load

Approx. 50 mA

Output current

Continuous

60 A

Current limit *

70 A

*Note:  In current limit condition, the output voltage will drop if the current drawn increases beyond the current 
limit value of 70 A

Output ripple and noise

less than 50 mV  RMS

Efficiency

Approx. 92%

Operating ambient temperature

-20 to +30

o

C

(derate linearly to 0 at 70º C) 

Humidity

Max. 95%, non condensing

Protections:
- Overload

By current limiting

- Over heating

Drop in output voltage

- Reverse polarity

Fuse protection, 30 A

- Over voltage

Varistor 

(also protects against load dump)

Input side fuse

60 A

 

(2 pieces of 32V, 30A in parallel)

Safety and EMC Standards:
- Emission

EN50081-1

- Immunity

EN50082-1

- Automotive directive

95/45/EC

Input / output connections

Terminal Block – (M6 Bolt & Nut)

Weight

2.6 lbs / 1.2 Kg

Dimensions (H x W x D)

3.6”   x   3.5”   x   7.0”(93   x   90   x 

177mm)
Warranty

5 years

NOTE: Specifications are subject to change without notice 

CAUTION! : THERE IS NO ISOLATION BETWEEN THE INPUT AND THE OUTPUT. INPUT AND 
OUTPUT HAVE A COMMON NEGATIVE 

Summary of Contents for CPC-60

Page 1: ...Owner s Manual Product DC DC Step Down Converter Model CPC 60 Thank you for purchasing a Canadian Power Conversion product Please read this manual before operating this converter ...

Page 2: ...ontal surface It can also be installed horizontally on a vertical surface Fans should not be pointing up or down The unit has temperature controlled fans for cooling The suction and discharge openings on the sides should not be blocked Note The fan will only come on if the unit gets hot Input and output connections The CPC 60 has a terminal block with 3 x M 6 bolt nut connections One is for positi...

Page 3: ...ut side must be able to carry a max current of approx 70 A To limit voltage drop to 2 use 4 AWG for distance up to 6 ft and 2 AWG for up to 10 ft Use ring type of terminals for M 6 bolt on the ends of the cables to enable connection to the M 6 bolts of the terminal block External fuses on the input and output sides The input and output connections should be made through 32 V 30A fast blow fuses Fo...

Page 4: ...y to 0 at 70º C Humidity Max 95 non condensing Protections Overload By current limiting Over heating Drop in output voltage Reverse polarity Fuse protection 30 A Over voltage Varistor also protects against load dump Input side fuse 60 A 2 pieces of 32V 30A in parallel Safety and EMC Standards Emission EN50081 1 Immunity EN50082 1 Automotive directive 95 45 EC Input output connections Terminal Bloc...

Page 5: ...Contact Information Corporate Address 10673 240A Street Maple Ridge B C Canada V3W 2B1 t 604 476 1553 f 604 123 4567 e cpc canadianpowerconversion com w www canadianpowerconversion com ...

Reviews: