20
Power str
oke
[r
evolutions]
Table 2 – Basic parameters of MODACT MONJ electric actuators
- supply voltage 1x230V, 50 Hz
Basic outfit: 2 position-limit switches (OPEN - PO, CLOSE - PZ); 2 torque-limit switches (OPEN - MO, CLOSE - MZ), 1 electric motor (brake motor upon special request);
2 anti-condensation heaters
Type No.
basic
additional
1 2 3 4 5
6 7 8 9 1 0
Type marking
Torque
[Nm]
Tripping Starting
Contr
ol
Adjusting
speed
[1/min]
Elektromotor
Power
[kW]
RPM
[1/min]
I
n
(230 V)
[A]
I
Z
In
MONJ 40/75-25
C
75
25
1LF7070-4
0,25
1400
1,86
3,4
27
x x 2 x NJ
MONJ 40/50-40
C
20
–
40
50
40
1LF7070-4
0,25
1400
1,86
3,4
27
x x 3 x NJ
MONJ 40/60-50
C
60
50
1LF7070-2
0,37
2895
2,85
3,5
27
x x 4 x NJ
MONJ 40/60-80
C
60 80
1LF7073-2
0,55
2860
4,15
3,7 27
52 030
x x 5 x NJ
MONJ 80/135-25
C
40 – 80
135
25
1LF7073-4
0,37
1400
2,6
3,2
27
x x 8 x NJ
MONJ 70/90-40
C
40 – 70
90
40
1LF7073-4
0,37
1400
2,6
3,2
28
x x 9 x NJ
MONJ 75/100-50
C
40 – 75
100
50
1LF7073-2
0,55
2860
4,15
3,7
28
x x A x NJ
MONJ 110/143-25
C 80 – 110
143
25
1LF7073-4
0,37
1400
2,6
3,2
28
x x E x NJ
MONJ 100/130-40
C 63 – 100
130
40
1LF7080-4
0,55
1415
3,5
3,6
41
x x 3 x NJ
MONJ 95/124-63
63 – 95
124
63
2-250 1LF7083-4
0,75
1405
4,8
3,9
42
x x 4 x NJ
MONJ 100/230-80
63 – 100
130
80
1LF7083-2
1,1
2860
6,7
4,4
43
x x E x NJ
MONJ 100/130-100
130
100
1LF7096-4
1,5
1430
8,7
4,3
50
x x 5 x NJ
MONJ 95/124-145
63 – 95
124
145
1LF7090-2
1,5
2845
9,25
4,5
51
52 031
x x F x NJ
MONJ 150/195-40
100 – 150
195
40
1LF7083-4
0,75
1405
4,8
3,9
41
x x 9 x NJ
MONJ 160/208-65
100 – 160
208
65
1LF7096-4
1,5
1430
8,7
4,3
42
x x A x NJ
MONJ 160/208-80
80
1LF7090-2
1,5
2845
9,25
4,5
43
x x H x NJ
MONJ 130/170-145
100 – 130
170
145
1LF7096-2
2,2
2830
13,3
4,8
51
x x J x NJ
MONJ 250/325-40
160 – 250
325
40
1LF7096-4
1,5
1430
8,7
4,3
45
52 032
x x 3 x NJ
MONJ 220/286-80
160 – 220
286
80
1LF7096-2
2,2
2830
13,3
4,8
49
x x 5 x NJ
Weight
[kg]
Type
with starting-up
and running
capacitor.
The actuators MODACT MONJ are fitted with single-phase electric motors Siemens series 1LF7... with running and starting-up capacitors.
The manufacturer guarantees 60,000 and 100,000 start-ups for two-pole electric motors (ca 2800 r.p.m.) and four-pole electric motors
(ca 1400 r.p.m.), respectively. Then, it is necessary to replace the centrifugal disconnector of the starting-up capacitor – it is available at
ZPA Pečky, a.s.
In ZPA Pečky, a.s. electric motors of power up to 0.37 kW are fitted with a triac disconnector that extends the service life to 350,000 start-ups.
If the actuator with a single-phase electric motor is to be used for regulating purposes, it is necessary to take this fact into consideration in
setting-up the regulation process (frequency of regulating interventions).
The expected working regime of the actuators MONJ should be discussed with the marketing department of ZPA Pečky, a.s.
Summary of Contents for MODACT MON 100/130-100