- 4 -
Function Test
Starting in “Test mode”
1) Start up the G1X in the following ways using the AC adaptor AD-0006.
a) Connect AC adaptor holding the [BANK UP
・
TAP] key (SW1) and [RHYTHM] key (SW2).
b) Connect AC adaptor when Ground and the test point TP1.
*When set 4 batteries, connect the plug into INPUT connector (J2)
2) All the LEDs of 7 segment LED will be lit.
1. Display (7 segment LED)
1) Make sure that all LEDs are lit brightly enough (indicate “8.8.”) after power on in “Test mode”.
2) Press any key and make sure that all LEDs will be turned off.
2. Module selector
1) Turn the Module selector (VR1) clockwise to “DECAY”.
2) Turn the Module selector (VR1) anticlockwise by one detent.
Make sure that the following indications appear on the 7 segment LED.
Module selector
7 segment LED
DECAY
15
REVERB
14
TIME
13
DELAY
12
RATE
11
MODULATION
10
ZNR/AMP
9
EQ_Hi
8
EQ_Mid
7
EQ_Lo
6
GAIN
5
DRIVE
4
COMP/EFX
3
PATCH LEVEL
2
RHYTHM
1
PLAY
0
3) Turn the Module selector (VR1) clockwise by one detent.
Make sure that the above values are indicated on the 7 segment LED depending on the
Module selector position.
Like figure 1 of the following page, make sure that replaced by right numerical value
at a click point and intermediate between click point.
In a range of the same click point, numerical value replaced is NG.