background image

 

 

 

 

www.zookdisk.com 

 

Serving America, Central & South America

 

16809 Park Circle Drive, Chagrin Falls,  

Ohio 44022 USA 

Toll Free: +1 800 543 1043 

Phone: +1 440 543 1010 

E-mail: [email protected] 

 

 

Serving Europe, Middle East & Africa

 

Navigation House, Bridge Street 

Killamarsh, Sheffield,  

S21 1AL UK 

Phone: +44 (0) 1909 560999 

E-mail: [email protected] 

 

Serving Canada 

4400 South Service Rd,  

Burlington, Ontario L7L 5R8 CA 

Toll Free: +1 800 370 6057 

Phone: +1 905 681 2885 

E-mail: [email protected] 

 

Serving Asia Pacific 

Unit No.23A-05, Menara Landmark, No.12,  

Jalan Ngee Heng 

80000 Johor Bahru, Johor, Malaysia 

Phone: +60 (7) 2910099 

E-mail: [email protected] 

Page 4 of 4      RT2_InstallationGuide_022219

 

                            Safety 

Through

 Knowledge 

and 

Performance 

 

 

INSTALLATION INSTRUCTIONS

 

Graphite and Metal Rupture Disk Holders 

Rupture Disk Series: RT2, RT2T, RE2, RE2T and Variants  

 

Typical RT2 Series Installation

 

Flanges and flange gaskets – user supply. Outlet flange and gasket omitted for clarity.

 

The disk tag is designed to provide critical information about the rupture disk and should NOT be used as a handle 
to hold, lift or adjust the assembly during installation. This practice can damage the disk resulting in failure of the 
disk.

 

 

 

 

Holder Outlet

 

 

 

 

Rupture Disk

 

 

 

 

Vacuum Support 

(Optional)

 

 

 

  Holder Inlet

 

 

 

 

Gasket

 

 

 

Companion Flange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow Direction 

Summary of Contents for RE2

Page 1: ...remature failure or over pressurization of the system c Particles may discharge when the rupture disk ruptures These particles may be part of the rupture diskitself or other environmental matter in the system It is the user s responsibility to ensure that particles are directed to a safe area to prevent personnel injury or property damage d Rupture disk service life is affected by corrosion fatigu...

Page 2: ...or to inserting the disk between the inlet and outlet insuring that ALL FLOW ARROWS ARE POINTING IN THE PROPER DIRECTION Do not lift the disk using the disk tag handle disk at the rim edge WARNING If the rupture disk is installed upside down the burst pressure may exceed the marked burst pressure PAY CLOSE ATTENTION TO THE DIRECTIONAL ARROWS ON THE RUPTURE DISK ASSEMBLY 3 Install new gaskets betwe...

Page 3: ... clamped surface there is no single correct tightening torque for all circumstances A range of values can be determined however given the anticipated frictional scatter The amount of frictional scatter which the engineer allows for when determining the clamp force and tightening torque should be based upon experimental results taken from the application b Recommended torque values do not consider ...

Page 4: ...ee Heng 80000 Johor Bahru Johor Malaysia Phone 60 7 2910099 E mail sales asia zookdisk com Page 4 of 4 RT2_InstallationGuide_022219 Safety Through Knowledge and Performance INSTALLATION INSTRUCTIONS Graphite and Metal Rupture Disk Holders Rupture Disk Series RT2 RT2T RE2 RE2T and Variants Typical RT2 Series Installation Flanges and flange gaskets user supply Outlet flange and gasket omitted for cl...

Reviews: