Diagnostics
These commands, which can be issued by Mpower, are included in this document to assist in the diagnosis
of problems.
The use of these commands is at the users own risk and is subject to change without notice.
Fn
Name
Purpose
Notes
0
Initialise
Initialise all modules
1
LoadDefaultConfiguration
Reset configuration.
All static configuration is set to factory defaults
2
Reserved
3
InitialisePC1Port
Re-initialise PC1 port.
Required after changes to comms settings
4
InitialisePC2Port
Re-initialise PC2 port.
Required after changes to comms settings
5
InitialisePC3Port
Re-initialise PC3 port.
Required after changes to comms settings, or AC video phone mode
6
InitialiseZvmPort
Re-initialise Zvm port.
Required after changes to comms settings.
7
Reserved
8
Reserved
9
InitialiseCmdHandler
Re-initialise command stack.
Discards all current commands. May cause memory loss. For
debugging only
10
Reserved
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
16
InitialiseDialup
Initialise call status
Assumes call status is idle
17
InitialiseMMT
Initialise 8120 board
Reloads all configuration into 8120, after power-up delay
18
InitialiseDTMF
Initialise DTMF interface
19
InitialiseVideoPhone
Initialise camera control status
Initialises control statuses used when no site controller is present