OPERATION 

The  MDPA2  is an extension of the MDP3  zone functions.  The 

MDPA2  must  use the same thermostat wiring configuration as the 

zones on the MDP3.   The MDPA2  is not used as a stand alone 

panel.   

 

On a call for heating or cooling, the panel will accept the first call from 

any zone, providing no other calls for heating or cooling exist in the 

system    Upon accepting this call the MDPA2  will open its zone 

damper(s), if not open already, close the damper(s) to those zones 

not calling, activate the needed HVAC controls for heating or cooling, 

whichever is being called and not accept any calls for the opposite 

mode.   

 

Any calls for the opposite mode will be locked out until the initial 

mode is either satisfied or a period of time has elapsed that is 

sufficient for the first mode to satisfy, a maximum of 20 minutes.  A 

Patent Pending sequence determines the time the unit has been 

running or needs to continue to run in order to adequately provide 

conditioning for each mode.  If a particular mode has already been 

calling for 20 minutes or longer and an opposite call comes in the 

MDPA2  will immediately drop the mode, enter the purge mode in 

order to dissipate the conditioned air into the zones calling before 

switching over to provide the new conditioning call to its zones.   

 

All other functions are identical to the MDP3 zone operation, see the 

MDP3 installation and operating instructions for further details.   

 

.  

 

WIRING  

The  MDPA2  is very simple to wire and requires only a minimum 

number of connections.  The MDPA2 color coded terminal blocks are 

screw-less and all wires can easily be pushed into their respective 

terminal by de-pressing the button for each point and releasing once 

the wire is seated.  To remove the wire, just press it's button again 

and remove the wire.   

 

Zone Dampers

 – 

The MDP3 provides DC power to ZONEFIRSTs' 

exclusive Plug-In Zone Dampers.  These dampers use and are 

supplied with a modular cord that is complete with RJ11 jacks on 

each end of a 25’ cable for each zone damper.  Up to 10 dampers 

can be wired to each zone.   

 

The panel has a GREEN LED to indicate when the damper should be 

open. Each damper motor has a two color LED that a positive 

indication of the damper being open or closed. When the LED is 

GREEN the damper is Open. When the LED is RED the damper is 

closed. 

 

         

ZONE DAMPER

ZONE DAMPER

 

 

 

WIRING DIAGRAM 1

 – 

Conventional Thermostat

 

 

 

Y

G

C

R

W/OB

E

ZO

NE

 T

HE

RM
O

ST

AT

 T

ERM
IN

A

LS

C  W    R   Y   G

ZONE THERMOSTAT

 

 

 

 

 

WIRING DIAGRAM 2

 

– Heat Pump Thermostat

 

 

    

             

Y

G

C

R

W/OB

E

ZO

NE

 T

HE

RM
O

ST

AT

 T

ERM
IN

A

LS

C  O/B R   Y   G   E 

ZONE THERMOSTAT

 

 

 

Zone Adder Connection

 – The MDPA2 panel communicates with 

the  MDP3  using  a CAT 5 cable.  A four (4’) foot CAT 5 cable is 

supplied with each MDPA2 panel.  This cable  is connected to the 

modular plug on the left side of the MDPA2 panel and the other end 

connected to the connector on the right side of the MDP3 panel.  Up 

to 50 additional MDPA2 panels are connected in the same way in a 

daisy chain from one MDPA2 panel to the next.  

 

 

Transformer

 

–  A 24VAC, 40VA transformer is required to power 

the panel.  This transformer is wiring to the 24VAC: C and 24VAC: R 

terminals on the lower left corner of the panel.  Before wiring to the 

MDPA2  panel, check the phasing of this transformer with the 

transformer that powers the MDP3  panel.  Ensure that both 

transformers are in phase with one another.  See directions on page 

4. 

 

CHECKOUT 

The  MDPA2  has unique features that simplify the checkout of the 

system and has LED readouts that constantly indicate the system 

operation.

 

 

 

POWER LED 

is constantly illuminated 

GREEN

  when 24VAC is 

applied to the MDPA2. The power LED will flash green when the 

MDP3/MDPA2 is in the test mode. 

 

 

HEAT LED

 

is constantly illuminated 

RED

  when MDP3/MDPA2  is 

calling for the first stage of heating, will flash two times (2X) when 

second stage heat energizes and will flash three times (3X) when the  

third stage of heat or emergency heat is energized. 

 

 

COOL  LED 

is constantly illuminated

  GREEN 

when the 

MDP3/MDPA2 is calling for the first stage of cooling and will flash two 

times (2X) when the second stage of cooling is energized. 

 

 

FAN LED

 

is constantly illuminated 

YELLOW

 when calling for the fan 

or when the compressor is running. 

 

 

ZONE DAMPER LEDs 

will constantly be illuminated

  GREEN 

when no zone is calling and indicating the zone dampers are in the 

open position.

When a zone calls for heating, cooling or fan that zone 

LED will remain illuminated and those zones not calling the LED will 

go out, indicating that the zone dampers are in the closed position 

 

 

 

 

 