background image

Installation

 1. Install the ZOLAR® Goose-Neck Rear Mount Plate [24] onto the Quick Mount Plate Base [03] of the LED panel;
2. Mount the LED panel onto light stand through the ZOLAR® Goose-Neck Rear Mount Plate [24], tighten the light 
    stand clamp until the LED panel is firmly secured; 
3.

 

Use the Adjustadle Lock Clamping Lever [25] on the ZOLAR® Goose-Neck Rear Mount Plate [24] to adjust to desired 

    position.

5

Menu Operation

 1.

 

Press Menu Button [19] on the Controller [07] to enter the menu;

2.

 

Rotate Rotary Encoder [17] clockwise to move cursor downward, anti-clockwise to move cursor upward. Press to

    confirm selection. Press Menu Button [19] to return to the upper level menu.

Power Supply

Power On/Off

 1. Verify power supply connection;
2. Turn Power Switch [09] to “ | ” position; 
3. To power off, simply turn Power Switch [09] to “O” position;

Using AC DC Power Adapter 36V

    
     1.

 

Slide the V-Mount battery to the V-Mount Battery Plate** [06] from the top of the Controller Unit [04];

    2.

 

Push gently downwards until lock into position;

    3. To unmount the battery, press and hold Quick Release Button [11], then lift the battery upward.

* Only 14.4V

~

28.8V V-Mount batteries can be used. Not included in the standard package.

**Controller Unit has V-mount and Gold-mount Battery options. The Gold-mount Battery option to be followed.

Using Battery*

  1. Connect ZOLAR® Controller Cable 8M [29] to 

Receptor Cable

 [01] of the LED panel;

 2.

 

Connect ZOLAR® Controller Cable 8M [29] to Controller Cable Port [12] of the Controller Unit [04];

 3.

 

Slide AC DC Power Adapter 36V [26] to the V-Mount Battery Plate [06] from the top, Push gently downwards until lock 

     into position;
 4. Connect output power plug of the AC DC Power Adapter 36V [26] to DC Power Input [11] of the Controller Unit [04];
 5. Connect AC Power Cable [28] to AC DC Power Adapter 36V [26];
 6. Connect AC power plug to AC power outlet (110

~

240V, 50/60Hz);

 7. To disconnect, make sure the Power Switch [09] is in OFF position, unplug AC Power Cable [28] from power outlet, 
     press and hold the safety lock of the AC DC Power Adapter 36V [26] to pull it out from the Controller Unit [04], rotate 
     and hold the safety lock of ZOLAR® Controller Cable 8M [29] to pull it out from the Controller Unit [04], repeat at the 
     other end to pull it out from the Controller Cable Port [01] of the LED panel.

Summary of Contents for Blade 60C

Page 1: ...Quick User Guide Blade 60C 1 inch thin LED Panel ZOLAR...

Page 2: ...tery Plate 08 Quick Release Button 01 Receptor Cable 02 Handle 03 Quick Mount Plate Base 07 Controller 09 Power Switch 10 V Mount Clip Front Rear Controller Unit Rear Front Right Left Right The Gold m...

Page 3: ...tton 21 F3 Button 22 F2 Button 23 F1 Button 07 Controller 29 ZOLAR Controller Cable 8M 28 AC Power Cable CN CN Plug UK Plug US Plug EU Plug Power plug varies according to socket types for each country...

Page 4: ...Controller Cable 16M ZOLAR Blade 60C Mounting Accessory Kit ZOLAR Honeycomb Grid 60D 60x30 ZOLAR Honeycomb Grid 30D 60x30 ZOLAR Rear Mount Plate with Junior Pin Yoke for ZOLAR Blade 60C 2x2 ZOLAR Rea...

Page 5: ...lar for the latest version of this document and updated product information Please contact Shenzhen ImagineVision Technology Limited hereinafter referred to as ImagineVision or its authorized distribu...

Page 6: ...ess and hold Quick Release Button 11 then lift the battery upward Only 14 4V 28 8V V Mount batteries can be used Not included in the standard package Controller Unit has V mount and Gold mount Battery...

Page 7: ...tones and increase magenta tones Each click decreases 0 01 lowest value is 1 00 4 Press F2 Button 22 again to lock the current value and quit the G M adjustment mode Intensity Adjustment 1 Press F3 Bu...

Page 8: ...ed Green Blue Yellow Magenta Cyan White Firmware upgrade in progress ZolarLink Master Unit disconnected ZolarLink Slave Unit disconnected Flashing 0 5s interval Error Normal Art Net sACN in use Warnin...

Page 9: ...nship issues by ImagineVision or its designated approved service partners within the warranty period ImagineVision or its designated approved service partners will carry out repair service or product...

Page 10: ...encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the...

Reviews: