Installation
1. Install the ZOLAR® Goose-Neck Rear Mount Plate [24] onto the Quick Mount Plate Base [03] of the LED panel;
2. Mount the LED panel onto light stand through the ZOLAR® Goose-Neck Rear Mount Plate [24], tighten the light
stand clamp until the LED panel is firmly secured;
3.
Use the Adjustadle Lock Clamping Lever [25] on the ZOLAR® Goose-Neck Rear Mount Plate [24] to adjust to desired
position.
5
Menu Operation
1.
Press Menu Button [19] on the Controller [07] to enter the menu;
2.
Rotate Rotary Encoder [17] clockwise to move cursor downward, anti-clockwise to move cursor upward. Press to
confirm selection. Press Menu Button [19] to return to the upper level menu.
Power Supply
Power On/Off
1. Verify power supply connection;
2. Turn Power Switch [09] to “ | ” position;
3. To power off, simply turn Power Switch [09] to “O” position;
Using AC DC Power Adapter 36V
1.
Slide the V-Mount battery to the V-Mount Battery Plate** [06] from the top of the Controller Unit [04];
2.
Push gently downwards until lock into position;
3. To unmount the battery, press and hold Quick Release Button [11], then lift the battery upward.
* Only 14.4V
~
28.8V V-Mount batteries can be used. Not included in the standard package.
**Controller Unit has V-mount and Gold-mount Battery options. The Gold-mount Battery option to be followed.
Using Battery*
1. Connect ZOLAR® Controller Cable 8M [29] to
Receptor Cable
[01] of the LED panel;
2.
Connect ZOLAR® Controller Cable 8M [29] to Controller Cable Port [12] of the Controller Unit [04];
3.
Slide AC DC Power Adapter 36V [26] to the V-Mount Battery Plate [06] from the top, Push gently downwards until lock
into position;
4. Connect output power plug of the AC DC Power Adapter 36V [26] to DC Power Input [11] of the Controller Unit [04];
5. Connect AC Power Cable [28] to AC DC Power Adapter 36V [26];
6. Connect AC power plug to AC power outlet (110
~
240V, 50/60Hz);
7. To disconnect, make sure the Power Switch [09] is in OFF position, unplug AC Power Cable [28] from power outlet,
press and hold the safety lock of the AC DC Power Adapter 36V [26] to pull it out from the Controller Unit [04], rotate
and hold the safety lock of ZOLAR® Controller Cable 8M [29] to pull it out from the Controller Unit [04], repeat at the