background image

B.TECHNICAL SPECIFICATION

C.OPERATION INSTRUCTION

D.TROUBLE SHOOTING

Note:

This troubleshooting is for reference purposes only. If any technical assistance in needed, please contact

your distributor for service.

MODEL

AIRFLOW

VOLTAGE

POWER

WATER

CAPACITY

DIMENSION

(cm)

N.W

ESC-45P-4R

4500cmh

110V/60Hz

120W

40L

49*36.5*97

12.5kg

ESC-50P-4R

5000cmh

110V/60Hz

150W

50L

56*37*110

15kg

ESC-60P-5RN

7000cmh

110V/60Hz

200W

70L

66*46*117

20kg

Keypad

Instruction

Comment

ON/OFF

Make the cooler start or stop to work.

Model

Normal / Natural / Sleep

Timer

To select 1H-12H working time

Speed

To select low, medium or high fan speed.

Swing

To make the vent auto swing(left and right)

Cooling

To make the pump start to work and activates the cooling function.

Night

Turn on/off the light of screen.

Malfunction

Reason

Solution

-Operating screen

stays dark

-No power

-Main control board failure

-Fuse is blown

-Panel failure

-Check unit is plugged in

-Change control board

-Change fuse

-Change panel

-Display is normal

But without air

Flow or the air

Speed is too low

-The fan is jammed

-Cooling pad or dust filter is

blocked

-Fan is distorted

-Main control board failure

-Check to ensure there is nothing

Preventing free rotation of the fan

-Clean the cooling pad and dust filter

-Change the fan

-Change the main control board

-Motor does not

Respond to control

panel

-Main control board failure

-Panel failure

-Change the main control board

-Change the panel

-Water leaking

From drain valve

-Drain valve is loose

-Dirt in valve

-Tighten drain valve nut

-Clean drain valve

-Air diffuser/swing

Function not working

-Synchronous motor burnt out

-Crankshaft is broken

-Change synchronous motor

-Change crankshaft

-Water drops splash

Out of the air diffuser

-Water pipe has come loose

-Check water pipe to top of filter pad

And reattach or tighten as necessary

Reviews: