7
P-48
Needle goes up as power
on
0-1
1
0
:
OFF 1
:
ON
P-49
Stitch
(
mm
)
1-7
3
Adjustment same as actual needle distance by up and
down key.
P-50
Up needle position
adjustment
0-1439
Same as P-72
P-51
Down position adjustment
0-1439
Same as P-73
P-52
Test speed
(
r/min
)
100-6000
5500
Adjustment by up and down key
P-53
Test working time
(
×100ms
)
1-250
50
Adjustment by up and down key
P-54
Test stop time
(
×100ms
)
1-250
20
Adjustment by up and down key
P-55
Item A testing
:
Continuous
running
0-1
0
0
:
STOP 1
:
RUN
P-56
Item B testing
:
With
function running
0-1
0
0
:
STOP 1
:
RUN
P-57
Item C testing
:
Without
function running
0-1
0
0
:
STOP 1
:
RUN
P-58
Machine plate protection
switch
0-1
1
0
:
OFF 1
:
ON
P-59
Presser foot protection
switch
0-1
1
0
:
OFF 1
:
ON
P-60
Electric /Air-powered
0-1
(
Electric machine type the default is 0, air-powered
machine type the default is 1
)
0
:
Electric 1
:
Air-powered
P-61
Trimming switch by
heeling pedal
0-7
7
0
:
All OFF 1
:
All ON by manually
2
:
Semi-auto ON 3
:
Auto ON
4
:
Manual and semi-auto ON
5
:
Semi-auto and auto ON
6
:
Manual and auto ON
7
:
Manual and semi-auto and auto ON
P-62
Rotate direction
0-1
0
Through Hand-wheel direction
:
0
:
Corotation (Clockwise)
1
:
Reversal (Counter clockwise)
P-63
Language
0-1
1
0
:
English 1
:
Chinese
P-64
The strength of front sensor
0%-100%
80%
Adjustment front sensor strength
P-65
The strength of mid-sensor
0%-100%
80%
Adjustment mid-sensor strength
P-66
The strength of back sensor
0%-100%
80%
Adjustment back sensor strength
P-67
The sensitivity of back
sensor
0-700
440
In order to adapt different cloth material setting
back-sensor receive strength.
P-69
Response time of back
sensor
(
ms
)
0-3000
0
Response time of back-sensor, when sewing such as
mesh cloth can adjust this item, then can achieve you
Summary of Contents for QD2622 Series
Page 9: ...9 ...