10
11
Clamp function without any thrum
12
Layer seam setting
13 Other
settings
14
Speed limit setting of main shaft motor start sewing
No. Items Range
Default Description
Parameter
3.1 Trimming function setting
3101
Trimming step return speed
20-400 150
P140
3102
Trimming first section
speed
20-400 300
P142
3103
Trimming second section
speed
20-400 250
P141
3104
Trimming action time
10-990
200
P55
3105
The angle of trimming first
infeed
0-359 40
P80
3106
The angle of trimming
second infeed
0-359 175
P82
3107
First trimming distance
0-200
90
P137
3108
Second trimming distance
0-200
125
P134
3109
Trimming step return time
10-990
100
P110
3110
Main shaft motor speed
when trimming
100-500 300
P49
3111
The stopping angle of
trimming first infeed
100-250 130
P81
3.2 Clamp function setting
3201
Clamp start angle
10-359 100
P78
3202
Clamp end angle
10-359 270
P79
3203
Wiper thread action time
10-990
220
P55
3204
The delay time before wiper
thread
5-990 5
P109
3.3 Presser foot setting
3301
Presser foot lay down time
10-990
120
P52
3302
Presser foot lift highness
compensation when pedal
return to intermediate step
at sewing stop
0-160 80
Set 80 as 0 compensation, go to the major
adjustment for positive compensation, the
height of the presser foot will increase, go to
the minor adjustment for the negative
compensation, the height of the presser foot
will decrease.
P125
3303
The highest of presser foot
lift highness
0-300 105
P136
3304
Presser foot speed
20-400
150
P146
3305
Zero correction of foot
lifting motor
-100
~
100
0
P130
3306
Presser foot step motor
steady current
10-100 20
P150
3307
Presser foot motor
maximum current
10-100 55
P152
3308
Electronic knee-control
device the lowest presser
0-200 20
P135