background image

 

10

11 

Clamp function without any thrum 

12 

Layer seam setting 

13 Other 

settings 

14 

Speed limit setting of main shaft motor start sewing 

 

No. Items  Range 

Default Description 

Parameter

3.1 Trimming function setting 

3101 

Trimming step return speed 

20-400 150 

 P140 

3102 

Trimming first section 
speed 

20-400 300 

 

P142 

3103 

Trimming second section 
speed 

20-400 250 

 

P141 

3104 

Trimming action time 

10-990 

200 

 

P55 

3105 

The angle of trimming first 
infeed 

0-359 40 

 

P80 

3106 

The angle of trimming 
second infeed 

0-359 175 

 

P82 

3107 

First trimming distance 

0-200 

90 

 

P137 

3108 

Second trimming distance 

0-200 

125 

 

P134 

3109 

Trimming step return time 

10-990 

100 

 

P110 

3110 

Main shaft motor speed 
when trimming 

100-500 300 

 

P49 

3111 

The stopping angle of 
trimming first infeed 

100-250 130 

 

P81 

3.2 Clamp function setting 

3201 

Clamp start angle 

10-359 100 

 

P78 

3202 

Clamp end angle 

10-359 270 

 P79 

3203 

Wiper thread action time 

10-990 

220 

 

P55 

3204 

The delay time before wiper 
thread 

5-990 5 

 

P109 

3.3 Presser foot setting 

3301 

Presser foot lay down time 

10-990 

120 

 

P52 

3302 

Presser foot lift highness 
compensation when pedal 
return to intermediate step 
at sewing stop 

0-160 80 

Set 80 as 0 compensation, go to the major 
adjustment for positive compensation, the 
height of the presser foot will increase, go to 
the minor adjustment for the negative 
compensation, the height of the presser foot 
will decrease. 

P125 

3303 

The highest of presser foot 
lift highness 

0-300 105 

 

P136 

3304 

Presser foot speed 

20-400 

150 

 

P146 

3305 

Zero correction of foot 
lifting motor 

-100

100

0  

P130 

3306 

Presser foot step motor 
steady current 

10-100 20 

 

P150 

3307 

Presser foot motor 
maximum current 

10-100 55 

 

P152 

3308 

Electronic knee-control 
device the lowest presser 

0-200 20 

 

P135 

Summary of Contents for A9200L-D4S-W-CP-Z

Page 1: ...ectors on the control box or motor 2 Threading needle 3 Raising the machine head 4 Repairing or doing any mechanical adjustment 5 Machines idling 14 Repairs and high level maintenance work should only...

Page 2: ...If click enter the parameter setting interface Lock screen key If you click switch the lock screen and unlock Mode selection If click shift to free sewing continuous back seam mode constant stitch sew...

Page 3: ...description 3 e needle stop po tween function N and full functi ch to tight seam tween automati ing full functio r cancelled half sewing mode I r cancelled bac r cancelled slow ter the advance nt valu...

Page 4: ...e 3rd pattern The figure is the data of the 3rd segment 3 1 99 1 represents the stitch numbers of the pattern As shown in the figure the number of stitches in the 3rd segment of the 3rd pattern is 1 4...

Page 5: ...s stitches in th 1 0 represe stitch sewing stitches lengt segments is ill be displayed efault 0 0 Descript ts the number o e As shown in th constant stitc ts the total num ch sewing mode egments can b...

Page 6: ...compensatio h length compe h overall compe h back tacking s ion ter setting int nterface of free ng interface cat tor setting nction setting setting g ng h setting on setting ay tting n without any t...

Page 7: ...16 tern sewing mpensation 1 tern sewing mpensation 2 unter selection 1 C speed 2 speed 2 r h whether ng mode the end of stitch stitch stitch stitch h h stitch stitch stitch stitch h h 0 12 0 5 0 100...

Page 8: ...m function P15 2602 Manual switch B setting 0 6 3 0 OFF 1 Half stitch 2 One stitch 3 Continuous half stitch 4 Continuous one stitch 5 Back tacking when machine stop or pause 6 Tight seam function P174...

Page 9: ...ghtness 2802 Main interface locked automatically 0 900 60 2803 Restore factory defaults 2804 Language Chinese English Chinese 2805 Brightness of Logo light 0 3 0 2 9 Layer seam setting 2901 Layer seam...

Page 10: ...30 P81 3 2 Clamp function setting 3201 Clamp start angle 10 359 100 P78 3202 Clamp end angle 10 359 270 P79 3203 Wiper thread action time 10 990 220 P55 3204 The delay time before wiper thread 5 990 5...

Page 11: ...ting 3501 Speed curve adjustment 10 100 80 P02 3502 The voltage of forward step pedal point 30 1000 520 P21 3503 The voltage of intermediate step pedal point 30 1000 420 P22 3504 The voltage of half h...

Page 12: ...ches distance of manual button D 0 6 0 0 P173 3714 Maximum stitch length limit 0 8 0 5 0 P123 3715 Back tacking response time when after free sewing end back tacking start 20 350 125 P77 3716 Large st...

Page 13: ...time m No limit when time is 0 1 3500 30 10 CCW 0 2 0 0 0 CCW 0 3 0 0 0 CCW 0 4 0 0 0 CCW 0 5 0 0 0 CCW 0 3 9 State information 3901 Version number 3902 Motor speed display Display current motor speed...

Page 14: ...needle position distance value 0 359 170 In the quick setting interface of the needle position for the upper and lower stops when the upper positioning value is saved the lower positioning value will...

Page 15: ...mit 0 5 0 4 0 3 13 Other setting 31301 Type selection 1 50 35 P70 3 14 Speed limit setting of main shaft motor start sewing 31401 First stitch speed limit of start sewing 0 1500 0 It is invalid when t...

Page 16: ...button A 1 2 Manual button B 2 3 Manual button C 3 4 LED light 4 5V 6 DGND 5 Manual button D 5 8P function port description 1 LOGO light 1 5 S5V 2 Oil level sensor 2 6 S5V 3 GND 3 7 4 Presser foot sen...