DESCRIPTION:

  The 

QWIK ALARM

®

 

  by Zoeller is a self-contained electronic device that sounds an alarm when the metal contacts of the sensor come in contact 

with water. The alarm is powered by four  (4)  AAA  

 batteries and features an audible low battery alarm by emitting a short beep periodically.  

 

LIMITED WARRANTY 

Zoeller Pump Company warrants, to the purchaser and subsequent owner during the warranty period, every new Zoeller Pump Company product to be free from 
defects in material and workmanship under normal use and service, when properly installed, used and maintained, for a period of one year from date of installation 

that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Zoeller Pump Company’s option, provided 
however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. No allowance will be made for shipping 
charges, damages, labor or other charges that may occur due to product failure, repair or replacement.

This warranty does not apply to any material that has been disassembled without prior approval of Zoeller Pump Company, subjected to misuse, misapplication, 
neglect, alteration, accident or act of nature; that has not been installed, operated or maintained in accordance with Zoeller Pump Company installation instructions; 
that has been exposed to but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons or hydrocarbon derivatives (oil, gasoline, solvents, etc), wash 
towels or feminine sanitary products, etc. or other abrasive or corrosive substances. This warranty is in lieu of all other warranties expressed or implied; and we do 
not authorize any representative or other person to assume for us any other liability in connection with our products.

Contact Zoeller  Pump  Company, [email protected]  Attention: Customer Support Department to obtain any needed repair or  replacement of part(s) or 

ZOELLER PUMP COMPANY EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED 
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED 
TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or 

limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

Original Instructions.

additional information pertaining to our warranty.

In those instances where damages are incurred as a result of an alleged pump failure, the Homeowner must retain possession of the pump for investigation purposes.

INSTALLATION

 Open the top cover to access the circuit board with battery holder sleeve.  Remove the circuit board from the battery holder sleeve and insert four AAA batteries 

into the battery container.  
Reinstall the circuit board and battery container into the battery holder sleeve ensuring that the brass clips on the side of the circuit board contact the brass strips 
on the side of the battery holder sleeve.  
Activate the alarm by setting the slide switch on the circuit board to L for low volume or H for high volume.
Slide the battery holder sleeve down the main body and ensure the brass contact strips touch the contact pins of the main body.
Test the QWIK ALARM

®

 by immersing the sensor contacts in water. You will hear three beeps every 5 seconds. This indicates that the unit is working properly. 

To silence alarm, simply remove the sensor contacts from the water and wipe them dry.  Blowing air across the sensor leads will remove any residual moisture 
that may still be on them.
Remove the tank lid from the QWIK JON

®

 PREMIER unit and use a hole saw to make a 2-3/8 inch (60 mm) diameter hole on the flat surface next to the discharge 

pipe. Use a deburring tool to clean up the hole. Insert the pipe seal with the QWIK ALARM

®

. The pipe seal may have to be slid halfway down the length of alarm 

and set in the opening before the alarm is inserted all the way in. A lubricant such as soapy water may be used.

1.

2.

3.
4.
5.
6.

7.

MAINTENANCE

Test your QWIK ALARM

®

 every 3 months and, if necessary, clean the silver color water level sensor contact area to ensure proper operation.

Under normal circumstances the four AAA batteries should provide approximately one year of service. REPLACE YOUR BATTERIES AT LEAST ONCE A YEAR 
to ensure proper operation.  NOTE: Damp locations or high temperature may reduce the battery life.
The alarm will sound one beep every 30 seconds if the battery is low.  Please change the batteries.

a)
b)

c)

Product information presented 

here re 

 

e

m

it 

t

a

 s

n

oi

t i

n

o

st

c

of  publication. Consult factory 

 r

o

 s

ei

n

p

e

r

si

d

 

g

ni 

d

r

a

e

r

.s

ei

n

e

t s

is 

n

o

ni

Register your

Zoeller Pump Company

Product on our website:

http://reg.zoellerpumps.com/

Visit our website:

www.zoellerpumps.com

Notice to Installer:  Instructions must remain with installation.

Reviews: