Zoeller ProPak AQUANOT Spin 508/53 Installation Instructions Manual Download Page 8

8

SPIN

 CONTROLLER FUNCTIONS

There are two buttons on the front of the controller.

 Silence/Reset

•  Can be pressed to silence current alarms for 24 hours.

• 

Can be held for longer than 3 seconds to reset alarm. Reset will clear flashing light on unit.

 

Test

•  Will run the pump to determine if amp draw of pump is in range. 

•  Controller is factory programmed to self-test the pump for several seconds every 24 hours.

•  Pressing the test button will start the 24-hour timer for self-testing.

Note: Holding both the silence/reset and test button at the same time for 5 seconds will cause a factory reset on the controller.

                                     AQUANOT

®

 SPIN

Solid 

Flashing

Off

System Ready

No Faults (Green)

AC off with no faults 

(Green)

--

Battery

Charged (Green)

Low Battery (Red)

No AC Power

Charging (Yellow)
Bad Battery (Red)

DC pump

Pump Ran (Yellow)

Pump Running (Yellow)

--

Pump Fault (Red)

Float Status

*High Water (Red) 

sensor activated

Float Fault (Red)

--

© Copyright 2020 Zoeller

®

 Co. All rights reserved.

The LEDs will display information about the controller. 

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality.  A defective battery will never 

become fully charged and may damage the charging circuits of the  Control. It is for this reason that Zoeller Pump Company offers its own 

line of batteries.  We offer both a water/acid deep-cycle battery and a maintenance-free AGM battery which can run the pump continuously 

for over 5 hours.  These times are based on continuous pumping at 8' (2.4 m) of static head. Actual times will vary depending on static 

head, volume of water entering the pit, and the condition of the battery.

Follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger

•  Do NOT use a “maintenance-free” battery unless it is an AGM battery

•  Replace your battery every 3 years

•  Do not let corrosion build up on the battery terminals

•  To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)

•  Use of the included plastic battery box is recommended to keep the battery safe and clean. 

PROTECT YOUR WARRANTY:  

•  Water level in batteries must be checked once a month (wet cell batteries only)

THE AQUANOT

®

 

BATTERY

CARBON MONOXIDE DETECTORS

Whether you have an Aquanot

®

 Backup Pump System or a competitive brand, all use batteries that give off gaseous by-products when charging. 

Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In 

order to help prevent false activation, Zoeller Pump Company recommends moving the battery as far away from the CO detector as possible 

or, if necessary, vent the battery to the exterior. Zoeller Pump Company provides the previous statements only as guidelines to help prevent 

false activation of the CO detector. In no way are they meant to supersede the instructions that accompany the detector, nor do they supersede 

advice from the CO detector manufacturer.

If the audible alarm associated with your CO detector is activated, we recommend the following actions:

1)  Take immediate action for personal safety as recommended in the CO detector literature.

2)  Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses 

natural gas.

3)  If you are certain that no CO is being produced, a charging battery may be producing gaseous by-products which are causing the CO detector 

to activate. Contact the manufacturer and ask for recommendations to prevent the alarm activation.

* If optional high water reed sensor is being used.

Summary of Contents for ProPak AQUANOT Spin 508/53

Page 1: ...a month Batteries contain acid and caution must be taken when handling 1 Check to be sure your power source is capable of handling the voltage requirements of the motor as indicated on the pump name plate 2 Vent hole It is necessary that all submersible sump effluent and sewage pumps capable of handling various sizes of solid waste be of the bottom intake design to reduce clogging and seal failure...

Page 2: ...ouspecificlegalrightsandyoumayalsohaveother rights which vary from state to state In instances where property damages are incurred as a result of an alleged product failure the property owner must retain possession of the product for investigation purpose 1 Electrical wiring and protection must be in accordance with National Electrical Code and any other applicable state and local electrical requi...

Page 3: ...ump pit too small D Pump will not shut off Debris under float assembly float bound by basin sides or other switch damaged or out of adjustment E Pump operates but delivers little or no water Check inlet strainer housing discharge pipe and vent holes for obstructions Discharge head exceeds pump capacity Low or incorrect voltage Incoming water containing air or causing air to enter pumping chamber I...

Page 4: ...ended that the controller is plugged into a separate circuit different than the primary pump 4 Make certain the float switch clamp is tight on the pipe to avoid slippage Ensure that the off level of the float is 1 25 mm min above the discharge tee of the DC backup pump see Figure 1 Position pumps in the sump and move float up and down making sure of free movement without interference from any obst...

Page 5: ...etorunonalowbattery without sufficient power to remove water Pump will not stop running until battery is below minimum voltage d CAUTION Weak batteries can be recharged but may not store sufficient energy for full service A weak recharged battery can only be detected by reduced pumping time or by professional load testing equipment If your emergency pump system is used frequently the battery shoul...

Page 6: ...SENSOR OPTIONAL TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM SK3182 SK3223 FIGURE 2 FIGURE 1 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE OPERATIONAL FLOAT SWITCH DC PUMP CLAMP HIGH WATER REED SENSOR OPTIONAL CHECK VALVE O RING M53 PRIMARY PUMP CLAMP AQUANOT SPIN Copyright 2020 Zoeller...

Page 7: ...ot limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK3185 FIGURE 3 Copyright 2020 Zoeller Co All rights reserved OPERATIONAL FLOAT SWITCH 30 AMP FUSE HI WATER REED SENSOR OPTIONAL BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT SPIN CONTROLLER FLOAT SWITCH...

Page 8: ...ycle battery 175 minute reserve capacity or larger Do NOT use a maintenance free battery unless it is an AGM battery Replace your battery every 3 years Do not let corrosion build up on the battery terminals To check specific gravity follow the instructions on a hydrometer wet cell batteries only Use of the included plastic battery box is recommended to keep the battery safe and clean PROTECT YOUR ...

Reviews: