Zoeller ProPak AQUANOT Spin 508/53 Installation Instructions Manual Download Page 7

7

MODEL

ProPak

508-D

ITEM

DESCRIPTION

QTY

02/19

thru

Current

Pump, 12 V DC with connector

1

155652

Battery box asm ( box and cover)

1

10-0764

Aquanot

®

 Spin

 controller

1

155978

Operational float switch

1

155654

High water reed sensor * optional

1

10-4830

Clamp, #28 worm-SS

2

004287

Inline check valve

1

153772

Pump, M53

®

/115 V

1

53-0001

Pump, M98/115 V

1

98-0001

Pipe, Pvc 1.5" X 10"/ Sch 40

1

019509

10

Fuse, 30 amp automotive

1

016918

CHECKLIST

EXPLODED VIEW - DC PUMP

All installations must comply with all applicable electrical and plumbing codes, including, but not limited to, National Electrical Code, local, regional, and/or state 
plumbing codes, etc.  Not intended for use in hazardous locations.

SK3185

FIGURE 3

© Copyright 2020 Zoeller

®

 Co. All rights reserved.

OPERATIONAL FLOAT SWITCH

30 AMP FUSE

HI-WATER REED SENSOR

(*OPTIONAL)

BATTERY BOX

DC PUMP

12 VOLT BATTERY 

SUPPLIED BY USER

WHITE LEAD TO POSITIVE

BLACK LEAD TO NEGATIVE

CLAMP

AQUANOT

®

 SPIN

 CONTROLLER

FLOAT SWITCH

LOCKING PIN MUST BE

INSTALLED UNDER FLOAT

ROD IN THIS LOCATION.

MOLEX 2-PIN CONNECTOR 

MOLEX 4-PIN CONNECTOR 

FIGURE 4

SK3186

CONTROL CHARGER

FLOAT STATUS LED

DC PUMP LED

BATTERY LED

SYSTEM READY LED

GROUNDED POWER CORD

SILENCE BUTTON

TEST BUTTON

WHITE LEAD

(POSITIVE)

BLACK LEAD

(NEGATIVE)

30 AMP FUSE

DC PUMP

HIGH WATER

OPERATIONAL

AQUANOT

®

 SPIN

 CONTROLLER

FIGURE 5

SK3187

Summary of Contents for ProPak AQUANOT Spin 508/53

Page 1: ...a month Batteries contain acid and caution must be taken when handling 1 Check to be sure your power source is capable of handling the voltage requirements of the motor as indicated on the pump name plate 2 Vent hole It is necessary that all submersible sump effluent and sewage pumps capable of handling various sizes of solid waste be of the bottom intake design to reduce clogging and seal failure...

Page 2: ...ouspecificlegalrightsandyoumayalsohaveother rights which vary from state to state In instances where property damages are incurred as a result of an alleged product failure the property owner must retain possession of the product for investigation purpose 1 Electrical wiring and protection must be in accordance with National Electrical Code and any other applicable state and local electrical requi...

Page 3: ...ump pit too small D Pump will not shut off Debris under float assembly float bound by basin sides or other switch damaged or out of adjustment E Pump operates but delivers little or no water Check inlet strainer housing discharge pipe and vent holes for obstructions Discharge head exceeds pump capacity Low or incorrect voltage Incoming water containing air or causing air to enter pumping chamber I...

Page 4: ...ended that the controller is plugged into a separate circuit different than the primary pump 4 Make certain the float switch clamp is tight on the pipe to avoid slippage Ensure that the off level of the float is 1 25 mm min above the discharge tee of the DC backup pump see Figure 1 Position pumps in the sump and move float up and down making sure of free movement without interference from any obst...

Page 5: ...etorunonalowbattery without sufficient power to remove water Pump will not stop running until battery is below minimum voltage d CAUTION Weak batteries can be recharged but may not store sufficient energy for full service A weak recharged battery can only be detected by reduced pumping time or by professional load testing equipment If your emergency pump system is used frequently the battery shoul...

Page 6: ...SENSOR OPTIONAL TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM SK3182 SK3223 FIGURE 2 FIGURE 1 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE OPERATIONAL FLOAT SWITCH DC PUMP CLAMP HIGH WATER REED SENSOR OPTIONAL CHECK VALVE O RING M53 PRIMARY PUMP CLAMP AQUANOT SPIN Copyright 2020 Zoeller...

Page 7: ...ot limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK3185 FIGURE 3 Copyright 2020 Zoeller Co All rights reserved OPERATIONAL FLOAT SWITCH 30 AMP FUSE HI WATER REED SENSOR OPTIONAL BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT SPIN CONTROLLER FLOAT SWITCH...

Page 8: ...ycle battery 175 minute reserve capacity or larger Do NOT use a maintenance free battery unless it is an AGM battery Replace your battery every 3 years Do not let corrosion build up on the battery terminals To check specific gravity follow the instructions on a hydrometer wet cell batteries only Use of the included plastic battery box is recommended to keep the battery safe and clean PROTECT YOUR ...

Reviews: