Zoeller ProPak 508 Series Installation Instructions Manual Download Page 6

6

© Copyright 2014 Zoeller Co. All rights reserved.

MODEL ProPak

508-A

ITEM DESCRIPTION

QTY

1/4

thru

Current

Pump, 12V DC with terminals

1

152962

Battery box

1

10-0764

DC control charger with terminals

1

153000

“Off”/”On” float switch

1

017197

Check valve (not shown)

1

019768

Hose coupling and clamps

1

019857

Pump, M53/115V (508-0006) 

1

53-0001

Pump, M98/115V (508-0007)

98-0001

1-1/2" PVC pipe tee

1

005645

1-1/2" X 2-1/8" long pipe

1

150197

10 

1-1/2" X 8-3/4" long pipe

1

010619

11

Fuse, 30 Amp AGC

1

012353

CHECKLIST

EXPLODED VIEW - DC PUMP

All installations must comply with all applicable electrical and plumbing codes, including, but not limited to, National Electrical 

Code, local, regional, and/or state plumbing codes, etc.  Not intended for use in hazardous locations.

SK2961

BATTERY BOX

12 VOLT

MARINE BATTERY

SUPPLIED BY USER

CLAMP

WHITE LEAD TO POSITIVE

BLACK LEAD

TO POSITIVE

WHITE LEAD

TO DC PUMP

BLACK LEAD

TO NEGATIVE

TO FLOAT

WHITE LEAD

30 AMP FUSE

DC CONTROL BOX

BLACK LEAD

TO NEGATIVE

TO FLOAT SWITCH

GREEN LEAD

SPLICER

FLOAT SWITCH

DC PUMP

FIGURE 3

Summary of Contents for ProPak 508 Series

Page 1: ...ly cord and strain relief or connect conduit directly to the pump 8 Installation and servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electric shock These pumps have not been investigated for use in swimming pool and marine areas 11 According to the state of C...

Page 2: ...may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In those instances where damages are incurred as a result of an alleged pump failure the Homeowner must retain possession of the pump for investigation purposes The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or...

Page 3: ... or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DO always connect to a separately protected and properly grounded circuit DO NOT ever cut splice or damage power cord Only splice in a watertight junction box DO NOT carry or lift pump by its power cord DO NO...

Page 4: ...CH 40 PVC TEE CHECK VALVE ASM W RUBBER COUPLING AND CLAMPS NOTE CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE FLOAT SWITCH DC PUMP M53 OR M98 PRIMARY PUMP TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM OUTLET PUMP PRIMARY 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BAT...

Page 5: ... located 3 or 4 ft above the sump 5 Connect the leads from the control charger to the battery terminals Positive lead to positive terminal and black neg lead to negative battery terminal Upon proper connection test alarm will sound Press alarm reset to silence This indicates proper charger to battery connection CAUTION Correct battery hook up is essential for operation of the system Use nuts suppl...

Page 6: ...ng pipe 1 150197 10 1 1 2 X 8 3 4 long pipe 1 010619 11 Fuse 30 Amp AGC 1 012353 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK2961 BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER CLA...

Page 7: ...ng impeller from rotating 6 Pump runs but pumps water intermittently a Pump is air locking Check flow of water incoming to sump If water is entering the sump at a high velocity creating a turbulent condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulence Divert...

Page 8: ... GROUNDED POWER CORD LCD AC POWER SCROLL CHARGED HIGH WATER CHARGING ALARM RESET LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH NEGATIVE LEAD POSITIVE LEAD FIGURE 4 sk2503 FIGURE 5 sk2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can be press...

Reviews: