background image

4

© Copyright 2014 Zoeller Co. All rights reserved.

SK2959

For Installation, 

Maintenance, 

Troubleshooting 

and Service 

Checklist, 

please 

refer to 

the corresponding Pump Installation Manual and Replacement Parts List.

SK301

1

1 1/2 SCH 40 PVC PIPE X 8 1/4"LG. (ALL

 MODELS)

1 1/2 SCH 40 PVC PIPE X 2 1/8"LG

1 1/2 SCH 40 PVC 

TEE

CHECK 

VAL

VE ASM

W

-RUBBER COUPLING

AND CLAMPS NOTE: CHECK V

AL

VE SCREWS

     INT

O PRIMAR

Y PUMP

 DISCHARGE.

 

HAND-TIGHTEN ONL

Y.

 

WEEP

 HOLE MUST

 BE

 

VISIBLE.

FLOA

T SWITCH

DC PUMP

M53 OR M98 PRIMAR

Y PUMP

TYPICAL

 INST

ALLA

TION

EXPLODED VIEW OF PUMP

 SYSTEM

OUTLET

PUMP

PRIMAR

Y

1" MIN.

IMPOR

TANT

: OFF LEVEL

 

OF 

FLOA

T ASSEMBL

MUST

 BE HIGHER 

THAN 

DC BACKUP

 PUMP

DC PUMP

 INST

ALLED IN LINE WITH SUBMERSIBLE PUMP

BA

TTER

Y BOX

DC CHARGER

OUTLET

CHARGER

R

R

FIGURE 1

FIGURE 2

Note: 

This drawing is dimensioned for clarity

.

Summary of Contents for ProPak 508 Series

Page 1: ...ly cord and strain relief or connect conduit directly to the pump 8 Installation and servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electric shock These pumps have not been investigated for use in swimming pool and marine areas 11 According to the state of C...

Page 2: ...may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In those instances where damages are incurred as a result of an alleged pump failure the Homeowner must retain possession of the pump for investigation purposes The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or...

Page 3: ... or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DO always connect to a separately protected and properly grounded circuit DO NOT ever cut splice or damage power cord Only splice in a watertight junction box DO NOT carry or lift pump by its power cord DO NO...

Page 4: ...CH 40 PVC TEE CHECK VALVE ASM W RUBBER COUPLING AND CLAMPS NOTE CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE FLOAT SWITCH DC PUMP M53 OR M98 PRIMARY PUMP TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM OUTLET PUMP PRIMARY 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BAT...

Page 5: ... located 3 or 4 ft above the sump 5 Connect the leads from the control charger to the battery terminals Positive lead to positive terminal and black neg lead to negative battery terminal Upon proper connection test alarm will sound Press alarm reset to silence This indicates proper charger to battery connection CAUTION Correct battery hook up is essential for operation of the system Use nuts suppl...

Page 6: ...ng pipe 1 150197 10 1 1 2 X 8 3 4 long pipe 1 010619 11 Fuse 30 Amp AGC 1 012353 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK2961 BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER CLA...

Page 7: ...ng impeller from rotating 6 Pump runs but pumps water intermittently a Pump is air locking Check flow of water incoming to sump If water is entering the sump at a high velocity creating a turbulent condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulence Divert...

Page 8: ... GROUNDED POWER CORD LCD AC POWER SCROLL CHARGED HIGH WATER CHARGING ALARM RESET LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH NEGATIVE LEAD POSITIVE LEAD FIGURE 4 sk2503 FIGURE 5 sk2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can be press...