background image

6

© Copyright 2014 Zoeller Co. All rights reserved.

MODEL ProPak

507-A

ProPak

507-B

ITEM DESCRIPTION

QTY

9/10

thru

8/13

9/13

thru

Current

Pump, 12V DC with terminals

1

017198

017198

Battery box

1

10-0764

10-0764

DC control charger with terminals

1

152899

152899

“Off”/”On” float switch

1

017197

017197

Check valve

1

019768

019768

Hose coupling and clamps

1

019857

019857

Pump, M53/115V (507-0008) 

1

53-0001

53-0001

Pump, M98/115V (507-0011)

98-0001

98-0001

Pump, WM49/115V (507-0009)

49-0005

49-0005

1-1/2" PVC pipe tee

1

005645

005645

1-1/2" X 2-1/8" long pipe

1

150197

150197

10 

1-1/2" X 8-3/4" long pipe

1

010619

010619

11

Fuse, 15 Amp

1

012352

012352

CHECKLIST

EXPLODED VIEW - DC PUMP

All installations must comply with all applicable electrical and plumbing codes, including, but not limited to, National Electrical 

Code, local, regional, and/or state plumbing codes, etc.  Not intended for use in hazardous locations.

SK2501

BATTERY BOX

12 VOLT

MARINE BATTERY

SUPPLIED BY USER

DC BACK-UP PUMP

CLAMP

FLOAT SWITCH

WHITE LEAD TO POSITIVE

BLACK LEAD

TO POSITIVE

WHITE LEAD

TO DC PUMP

BLACK LEAD

TO NEGATIVE

15 AMP FUSE

DC CHARGER

BLACK LEAD

TO NEGATIVE

TO FLOAT SWITCH

GREEN LEAD

SPLICER

WHITE LEAD TO FLOAT

FIGURE 3

Summary of Contents for ProPak 507 Series

Page 1: ...upply cord and strain relief or connect conduit directly to the pump 8 Installation and servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electric shock These pumps have not been investigated for use in swimming pool and marine areas 11 According to the state o...

Page 2: ...ay not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In those instances where damages are incurred as a result of an alleged pump failure the Homeowner must retain possession of the pump for investigation purposes The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or ...

Page 3: ...el or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DO always connect to a separately protected and properly grounded circuit DO NOT ever cut splice or damage power cord Only splice in a watertight junction box DO NOT carry or lift pump by its power cord DO ...

Page 4: ...lation Manual and Replacement Parts List SK2752 TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM FIGURE 1 BATTERY BOX IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE 1 MIN ABOVE CENTER OF TEE SEE INSTALLATION NOTE 3 VERIFY WEEP HOLE IS VISIBLE SEE PUMP INSTALLATION INSTRUCTIONS CHECK VALVE WEEP HOLE PROVIDED PUMP DISCHARGE 1 MIN DETAIL A SCALE 4X SEE DETAIL A FIGURE 2 ...

Page 5: ...and anchors provided If more convenient the control charger may be set on a nearby shelf or ledge The control charger should be located 3 or 4 ft above the sump To reduce noise from vibration it is recommended that the charger be anchored with the wall bracket provided INITIAL START UP AND OPERATION 1 Test the installation for leaks by running water into the sump allowing for normal operation of t...

Page 6: ... 1 2 PVC pipe tee 1 005645 005645 9 1 1 2 X 2 1 8 long pipe 1 150197 150197 10 1 1 2 X 8 3 4 long pipe 1 010619 010619 11 Fuse 15 Amp 1 012352 012352 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous loc...

Page 7: ...preventing impeller from rotating 6 Pump runs but pumps water intermittently a Pump is air locking Check flow of water incoming to sump If water is entering the sump at a high velocity creating a turbulent condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulenc...

Page 8: ...ION R R GROUNDED POWER CORD LCD AC POWER SCROLL CHARGED HIGH WATER CHARGING ALARM RESET LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH NEGATIVE LEAD POSITIVE LEAD FIGURE 4 SK2503 FIGURE 5 SK2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can b...

Reviews: