FLOAT SWITCH

CONTROL CHARGER

FIG. 4

LOCKING PIN MUST BE

INSTALLED UNDER FLOAT

ROD IN THIS LOCATION.

NON-GROUNDED

POWER CORD

ALARM RESET

POWER ON

BLACK LEAD TO

NEG. BATTERY TERMINAL

BLUE LEAD TO

FLOAT SWITCH

TO POS. BATTERY TERMINAL

BLACK WITH RED TRACER

"RED"

"CHARGING-YELLOW"

"CHARGED-GREEN"

INDICATOR

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become 

fully charged and may damage the charging circuits of the Control. It is for this reason that Zoeller offers its own line of batteries. We offer both 

a Water/Acid Deep-Cycle Battery and maintenance-free AGM battery which can run the pump continuously for over 7½ hours.  These times 

are based on continuous pumping at 10' of static head. Actual times will vary depending on static head, volume of water entering the pit, and 

the condition of the battery.

follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger.

•  Do NOT use a “maintenance-free” battery unless it is a Gel-filled or AGM battery.

•  Replace your battery every 3 years.

•  Do not let corrosion build up on the battery terminals.

•  Do not place your battery on a concrete floor where it will discharge faster.

•  To check specific gravity, follow the instructions on a hydrometer (not applicable for Gel or AGM batteries).

PRotect YoUR WARRAntY:  

•  Water level in batteries must be checked once a month (not applicable for Gel or AGM batteries).

THE AQUANOT

®

 

BATTERY

FIGURE 5

SK2503

FIGURE 6

SK1424

Summary of Contents for Basement Sentry Series

Page 1: ...nown to the state of California to cause cancer and birth defects or other reproductive harm 1 Make sure there is a properly grounded 115V receptacle available Do not use primary pump circuit The location must be within 6 of the control box and battery The power supply for your DC control system plugs directly into the 115V outlet Do not use an extension cord 2 Make sure the 115V electrical supply...

Page 2: ...warranty valid only when a complete system is purchased and used as a backup to a primary dewatering system A complete system includes a Model 507 or 510 Basement Sentry and an Aquanot Battery 1 Inspectandtestthesystemforproperoperationsatleastevery3months a Red power on indicator light should be on indicating AC power is on b Unplug primary pump and the control charger from power supply c Fill su...

Page 3: ...A CHECKLIST PERFORMANCE The DC emergency pump system requires a good quality 12 volt battery to obtain maximum pumping time during a power outage A deep cycle 12 volt 105 amp hour marine battery or larger is recommended and will provide approximately 7 hours of continuous pumping time in a sump pump installation with 8 of head pressure In most installations the pump runs intermittently and the bat...

Page 4: ...primary pump 4 If primary pump is installed disconnect power If the primary pump is a column pump with adjustable float and you are installing per figure 2 check the on point and adjust to approximately 7 from bottom of pump see figure 2 Mark the discharge pipe 7 above the on point of the primary column pump or 7 above the top of the primary submersible pump 5 If existing discharge pipe is metal o...

Page 5: ...g NOTE Pump must be mounted on a 30º angle to avoid airlocking OUTLET PUMP PRIMARY 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP VERIFY WEEP HOLE IS PRESENT IN MAIN DISCHARGE LINE SEE PUMP INSTALLATION INSTRUCTIONS BATTERY BOX BATTERY BOX OUTLET PRIMARY PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN SK2499 SK2500 ...

Page 6: ...USER FIG 5 DC BACK UP PUMP CLAMP FLOAT SWITCH BLACK WITH RED TRACER TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE TO FLOAT RED LEAD 15 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH BLUE LEAD SPLICER WHITE OR TOP VIEW IMPORTANT MAKE SURE THIS LINE IS GLUED IN POINTING UP 1 11 6 SUPPLIED BY CUSTOMER DISCHARGE PIPE ...

Page 7: ...ance free AGM battery which can run the pump continuously for over 7 hours These times are based on continuous pumping at 10 of static head Actual times will vary depending on static head volume of water entering the pit and the condition of the battery Follow these recommendations Use a B C I size 27 deep cycle battery 175 minute reserve capacity or larger Do NOT use a maintenance free battery un...

Page 8: ...hat accompany the detector nor do they supersede advice from the CO detector manufacturer If the audible alarm associated with your CO detector is activated we recommend the following actions 1 Take immediate action for personal safety as recommended in the CO detector literature 2 Contact the appropriate agency to determine if the CO is being produced by your furnace water heater or any other dev...

Reviews: