 1.  Dc pump won’t run
 

(a)  Check fuse in line from control box center to the battery (see fig. 5) 

If fuse is blown, replace.

 

(b)  Check for proper connections.

 

(c)  Check all wire terminal points. Clean if required.

 

(d)  Check for low battery. Service battery if required.

 2.  pump runs but pumps very little or no water. 
 

(a) Check for weak battery. Weak battery slow pulse alarm will sound 

and “yellow” light will blink.  Battery will recharge if “Red” power 

“on” light indicates power has been restored and the float switch 

is in the off position.

 

(b)  If immediate usage is required, remove and replace dead battery 

with a full recharged battery or place an additional battery in parallel.

 

(c)  Due to varying conditions, the pump may continue to run on a weak 

battery without sufficient power to remove water before the low battery 

alarm is activated.  Pump will stop running when low battery alarm 

is activated.

 (d) 

 Weak batteries can be recharged but may not store 

sufficient energy for full service. A weak recharged battery can only 

be detected by reduced pumping time or by checking each cell with 

a hydrometer. If your emergency pump system is used frequently, 

the battery should be checked by a qualified battery dealer.

 3.  pump cycles too frequently.
 

(a)  Check tether length on variable level float switch.

 

(b)  Lengthen tether as required. 4" recommended for standard 

installations.

 4.  Float switch in “on” position. pump won’t run.
 

(a)  Remove pump. Check for obstruction in pump preventing impeller 

from rotating.

 5.  pump runs, but pumps water intermittently.
 

(a)  Pump is air locking. Check flow of water incoming to sump. If 

water is entering the sump at a high velocity creating a turbulent 

condition, a mixture of air and water may cause a complete 

or partial air lock and reduce or stop the flow of water in the 

discharge pipe.

 

(b)  Baffle the incoming stream of water to reduce turbulence. Diverting 

water stream against wall of basin usually corrects an air lock 

problem.

 6.  Water level high, pump startup delayed.
 

(a)  Battery is weak, if battery terminal voltage has dropped to 10.5 

volts, the control box automatically shuts off the system for 

10 minutes and activates the low battery fast pulse alarm. If 

main power supply is off, a good quality battery may recover 

without recharging if the float is in the “off” position, and allow 

some additional pumping time. If main power supply is “on”, the 

primary pump will lower the water level and the battery will begin 

recharging.  The battery is low if battery terminal voltage drops to 

8.5 volts.  The control box automatically shuts off the system and 

activates a fast pulse alarm.  The system can not be restarted 

until power is restored and the battery recharged.

 

(b)  If power has been restored and water in sump remains high, 

check primary pump. Service if required.

  

(c)  A completely drained battery may require 18 hours for a full charge.

 7.  Alarm sounds during battery recharge cycle.
 

(a)  Push alarm reset (max. 3 times). If condition persists, replace battery.

tRoubLeShootinG inFoRMAtion

Manufacturer warrants, to the purchaser and subsequent owner during 

the warranty period, every new product to be free from defects in material 

and workmanship under normal use and service, when properly used and 

maintained, for a period of three years from date of purchase by the end 

user.  Parts that fail within the warranty period, that inspections determine 

to be defective in material or workmanship, will be repaired, replaced or 

remanufactured at Manufacturer's option, provided however, that by so doing we 

will not be obligated to replace an entire assembly, the entire mechanism or the 

complete unit.  No allowance will be made for shipping charges, damages, labor 

or other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or act of 

God; that has not been installed, operated or maintained in accordance with 

Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following:  sand, gravel, cement, 

mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, 

etc.), or other abrasive or corrosive substances, wash towels or feminine 

sanitary products, etc. in all pumping applications.  The warranty set out in 

the paragraph above is in lieu of all other warranties expressed or implied; and 

we do not authorize any representative or other person to assume for us any 

other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, 

Attention: Product  Support Department to obtain any needed repair or 

replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF 

EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY 

OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY 

SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, 

so the above limitation may not apply to you. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

Summary of Contents for BASEMENT SENTRY II

Page 1: ...chemicals known to the state of California to cause cancer and birth defects or other reproductive harm 1 Makesurethereisaproperlygrounded115Vreceptacleavailable Do not use primary pump circuit The location must be within 6 of the control box and battery The power supply for your DC control system plugs directly into the 115V outlet Do not use an extension cord 2 Make sure the 115V electrical supp...

Page 2: ...an not be restarted until power is restored and the battery recharged b If power has been restored and water in sump remains high check primary pump Service if required c Acompletelydrainedbatterymayrequire18hoursforafullcharge 7 Alarm sounds during battery recharge cycle a Pushalarmreset max 3times Ifconditionpersists replacebattery Troubleshooting Information Manufacturer warrants to the purchas...

Page 3: ...Deep cycle 12 volt 130 amp hour marine batteries are recommended and will provide approximately 7 hours of continuous pumping time in a sump pump installation with 8 of head pressure In most installations the pump runs intermittently and the battery life is extended accordingly Batteries with top terminals are recommended for ease of installation Pumping time can also be extended by using addition...

Page 4: ...at switch assembly on the lower leg of the discharge outlet tee using the clamp provided see fig 1 and 2 Set tether length to 4 Position pumps in the sump and move float up and down making sure of free movement without interference from any obstructions inside the sump or lid Very shallow sumps may require some adjustment to avoid overfilling or backing up of water into the sump inlet The float sw...

Page 5: ... The 8 3 8 Dimension can be altered to accommodate small basins with min depth of 24 ON LEVEL PRIMARY PUMP END OF PIPE END OF PIPE 7 3 16 PIPE REMOVED OUTLET PUMP PRIMARY BATTERY BOX 8 3 8 5 3 8 1 8 WEEP HOLE 1 8 WEEP HOLE BATTERY BOX PRIMARY PUMP ON LEVEL 7 1 2 5 3 8 8 3 8 END OF PIPE END OF PIPE 7 3 16 PIPE REMOVED PRIMARY PUMP OUTLET ...

Page 6: ...served PUMP LOOP ASSEMBLY FIGURE 3 FIGURE 4 FLOAT SWITCH SK1220 SK957 4 C B A C B A 9 8 5 6 6 7 5 10 1 PUMP LOOP ASSEMBLY BRACKET AND BOTTOM VIEW OF PUMP SUPPLIED BY CUSTOMER DISCHARGE PIPE 1 8 WEEP HOLE 1 8 WEEP HOLE CLAMP PIPE CLAMP 4 TETHER ...

Page 7: ...ICATOR YELLOW PUMP MODE INDICATOR LEAD TO POSITIVE BATTERY TERMINAL LEAD TO NEGATIVE BATTERY TERMINAL FEMALE PLUG FOR PUMP CONNECTION FEMALE PLUG FOR FLOAT SWITCH CONNECTION NONGROUNDED POWER CORD ALARM SILENCE INDICATOR PUMP RUN INDICATOR RED LED YELLOW GREEN LED RED LED YELLOW LED CHARGER RESET LESS THAN 3 SECONDS PUMP TEST GREATER THAN 3 SECONDS TEST SWITCH RED LOW BATTERY INDICATOR ALARM SILEN...

Page 8: ... and the condition of the battery Follow these recommendations Use a B C I size 27 deep cycle battery 175 minute reserve capacity or larger Do NOT use a maintenance free battery unless it is a Gel filled or AGM battery Replace your battery every 3 years Do not let corrosion build up on the battery terminals Do not place your battery on a concrete floor where it will discharge faster To check speci...

Reviews: