FIGURE 4

SK2962

SK2961

EXPLODED VIEW - DC PUMP

PUMP ASSEMBLY

FIGURE 3

(SUPPLIED BY CUSTOMER)

DISCHARGE PIPE

DC PUMP

DISCHARGE TEE

REDUCER FITTING

CLAMP

CHECK VALVE ASSEMBLY

BATTERY BOX

12 VOLT

MARINE BATTERY

SUPPLIED BY USER

CLAMP

WHITE LEAD TO POSITIVE

BLACK LEAD

TO POSITIVE

WHITE LEAD

TO DC PUMP

BLACK LEAD

TO NEGATIVE

TO FLOAT

WHITE LEAD

30 AMP FUSE

DC CONTROL BOX

BLACK LEAD

TO NEGATIVE

TO FLOAT SWITCH

GREEN LEAD

SPLICER

FLOAT SWITCH

DC PUMP

UPPER RUBBER STOP NOT USED ON

FACTORY ASSEMBLED SYSTEMS.

Summary of Contents for Aquanot 508

Page 1: ... and birth defects or other reproductive harm 1 Make sure there is a properly grounded 115V receptacle available Do not use primary pump circuit The location must be within 6 of the control box and battery The power supply for your DC control system plugs directly into the 115V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115V electrical supply circuit is equipped with fuses or circuit brea...

Page 2: ...a Model 508 and an Aquanot Battery 1 Inspect and test the system for proper operations at least every 3 months a Red power on indicator light should be on indicating AC power is on b Unplug primary pump and the control charger from power supply c Fill sump with water to the on level for the DC pump Allow pump to run a few minutes d The alarm will sound approximately 3 seconds after the pump starts...

Page 3: ...als are recommended for ease of installation Wet cell batteries contain acid and proper precaution must be taken when handling Maximum battery size 13 Length x 7 Width x 9 Height BATTERY SELECTION Discharge Feet of Head 5 10 15 20 22 Flow Gal per min 39 30 20 6 Shut off Head The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump fail...

Page 4: ... floor is recommended 16 Plug the charger s cord into charger and the 115V wall outlet The primary sump pump and the control box should be on separate circuits 17 Reconnect power to primary sump pump 18 Optional A dongle may be used to input a name and number into the charger for service information to the end user 19 Optional On the bottom of the charger there is a pair of dry contacts to signal ...

Page 5: ... tee determines the height of the DC pump A shorter piece of pipe may be beneficial in some installations This drawing is dimensioned for clarity OUTLET PUMP PRIMARY 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX DC CHARGER OUTLET CHARGER R R FIG 2 BATTERY BOX OUTLET PRIMARY PUMP DC PUMP INSTALLED IN LINE W...

Page 6: ... REDUCER FITTING CLAMP CHECK VALVE ASSEMBLY BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER CLAMP WHITE LEAD TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE TO FLOAT WHITE LEAD 30 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH GREEN LEAD SPLICER FLOAT SWITCH DC PUMP UPPER RUBBER STOP NOT USED ON FACTORY ASSEMBLED SYSTEMS ...

Page 7: ...CD will always display the battery voltage and current going to the battery if charging The alarm screen shows current alarms The cycle counter screen shows how many times the DC float has been activated The AC power loss counter screen shows how many times the AC power has been removed from the charger Optional a screen may also show the name and number of a service provider The 6 LED lights also...

Page 8: ...anufacturer and ask for recommendations as to what can be done to prevent the alarm activation MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Your Peace of Mind is Our Top Priority visit our web site www zoeller com There are millions of batteries manufactured each year so it is impossible to guarantee...

Reviews: