The DC controller is equipped with a 10 amp charger for maintaining the 

battery in a ready state and recharging the battery after use when AC power 

is restored. Time for recharge depends upon the amount of power consumed 

by the pumping cycle during the AC power interruption. The pump may go 

back to the ready run position in a very short period of time. A completely 

drained battery may require up to 24 hours for full recharge. If battery does 

not charge properly, the LCD will display BATFAIL and alarm will sound.

PERFORMANCE

The DC pump performance with fully charged 12V battery

The DC emergency pump system requires a good quality, 12 volt battery to 

obtain maximum pumping time during a power outage. A deep-cycle, 12 volt, 

105 amp-hour marine battery or larger is recommended and will provide ap-

proximately 6 hours of continuous pumping time in a sump pump installation 

with 8' of head pressure. In most installations the pump runs intermittently 

and the battery life is extended accordingly. Batteries with top terminals are 

recommended for ease of installation. "Wet" cell batteries contain acid and 

proper precaution must be taken when handling. Maximum battery size 13½" 

Length x 7" Width x 9½" Height.

BATTERY SELECTION

Discharge

Feet of Head

5

10

15

20

22

Flow

Gal. per min.

39

30

20

6

Shut-off

Head

The DC emergency pump is 

designed as a backup to your 

primary sump pump during 

unexpected power outages or 

primary pump failure. The DC 

pump, electronic controls and all 

the parts required for installation 

are included except the battery 

which is supplied by the user. The 

system is designed for installation 

in sumps with minimum of 18" 

diameter and 24" deep. For 18" x 

22" applications, consult factory.

DESCRIPTION

8

12 VOLT BATTERY

SUPPLIED BY USER

5

4

7

6

2

9

1

11

10

3

Model 508

Item Description

Qty

508-A

01/14

thru Current

1

Pump 12V DC / Backup (Service Part)

1

152962

2

Fitting, PVC 1.5" Tee / Sch 40 / (Pressure Fitting)

1

005645

3

Fuse, 250V / Agc-30

1

012353

4

Switch, Float / Vert Master 

1

017197

5

Clamp, #28 Worm-SS (Float Switch)

1

012724

6

Valve, Check / 1.5 Inline / Vertical

1

019768

7

Charger, DC Asm / Switch Mode

1

153000

8

Battery Box Asm (Box and Cover)

1

10-0764

9

Hardware Pak, Charger / Switch Mode

1

152864

10

Fitting, Asm & Clamp "508" (Service part)

1

152969

11

Flapper Asm, (Service part)

1

152970

SK3008

Summary of Contents for Aquanot 508

Page 1: ... and birth defects or other reproductive harm 1 Make sure there is a properly grounded 115V receptacle available Do not use primary pump circuit The location must be within 6 of the control box and battery The power supply for your DC control system plugs directly into the 115V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115V electrical supply circuit is equipped with fuses or circuit brea...

Page 2: ...a Model 508 and an Aquanot Battery 1 Inspect and test the system for proper operations at least every 3 months a Red power on indicator light should be on indicating AC power is on b Unplug primary pump and the control charger from power supply c Fill sump with water to the on level for the DC pump Allow pump to run a few minutes d The alarm will sound approximately 3 seconds after the pump starts...

Page 3: ...als are recommended for ease of installation Wet cell batteries contain acid and proper precaution must be taken when handling Maximum battery size 13 Length x 7 Width x 9 Height BATTERY SELECTION Discharge Feet of Head 5 10 15 20 22 Flow Gal per min 39 30 20 6 Shut off Head The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump fail...

Page 4: ... floor is recommended 16 Plug the charger s cord into charger and the 115V wall outlet The primary sump pump and the control box should be on separate circuits 17 Reconnect power to primary sump pump 18 Optional A dongle may be used to input a name and number into the charger for service information to the end user 19 Optional On the bottom of the charger there is a pair of dry contacts to signal ...

Page 5: ... tee determines the height of the DC pump A shorter piece of pipe may be beneficial in some installations This drawing is dimensioned for clarity OUTLET PUMP PRIMARY 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX DC CHARGER OUTLET CHARGER R R FIG 2 BATTERY BOX OUTLET PRIMARY PUMP DC PUMP INSTALLED IN LINE W...

Page 6: ... REDUCER FITTING CLAMP CHECK VALVE ASSEMBLY BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER CLAMP WHITE LEAD TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE TO FLOAT WHITE LEAD 30 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH GREEN LEAD SPLICER FLOAT SWITCH DC PUMP UPPER RUBBER STOP NOT USED ON FACTORY ASSEMBLED SYSTEMS ...

Page 7: ...CD will always display the battery voltage and current going to the battery if charging The alarm screen shows current alarms The cycle counter screen shows how many times the DC float has been activated The AC power loss counter screen shows how many times the AC power has been removed from the charger Optional a screen may also show the name and number of a service provider The 6 LED lights also...

Page 8: ...anufacturer and ask for recommendations as to what can be done to prevent the alarm activation MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Your Peace of Mind is Our Top Priority visit our web site www zoeller com There are millions of batteries manufactured each year so it is impossible to guarantee...

Reviews: