background image

6

AQUANOT

® 

SPIN

 FLOAT SWITCH

FIGURE 3

SK3186

SPIN

 CONTROLLER FUNCTIONS

There are two buttons on the front of the controller.

 

- Silence/Reset

•  Can be pressed to silence current alarms for 24 hours.
• 

Can be held for longer than 3 seconds to reset alarm. Reset will clear flashing light on unit.

 

- Test

•  Will run the pump to determine if amp draw of pump is in range. 

•  Controller is factory programmed to self-test the pump for several seconds every 24 hours.

•  Pressing the test button will start the 24-hour timer for self-testing.

Note: Holding both the silence/reset and test button at the same time for 5 seconds will cause a factory reset on the controller.

AQUANOT

®

 SPIN

Solid 

Flashing

Off

System Ready

No Faults (Green)

AC off with no faults (Green)

--

Battery

Charged (Green)

Low Battery (Red)

No AC Power

Charging (Yellow)
Bad Battery (Red)

DC pump

Pump Ran (Yellow)

Pump Running (Yellow)

--

Pump Fault (Red)

Float Status

*High Water (Red)

Sensor Activated 

Float Fault (Red)

--

The LEDs will display information about the controller. 

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

LOCKING PIN MUST BE

INSTALLED UNDER FLOAT

ROD IN THIS LOCATION.

MOLEX 4-PIN CONNECTOR

MOLEX 2-PIN CONNECTOR 

FIG. 4

DC PUMP

DISCHARGE TEE

REDUCER FITTING

CLAMP

CHECK VALVE ASSEMBLY

CLAMP

SK2962

FIGURE 4

FLOAT STATUS LED

DC PUMP LED

BATTERY LED

SYSTEM READY LED

GROUNDED POWER CORD

SILENCE BUTTON

TEST BUTTON

WHITE LEAD

(POSITIVE)

BLACK LEAD

(NEGATIVE)

30 AMP FUSE

DC PUMP

HIGH WATER

OPERATIONAL

AQUANOT

®

 SPIN

 CONTROLLER

SK3187

* If optional high water reed sensor is being used.

Summary of Contents for AquaNot 508 Spin

Page 1: ... tanks to pump effluent or in sewage pits to pump sewage 4 Repair and service of your DC backup system should be performed by an authorized service station 5 TheinstallationofDCautomaticbackuppumpsrequirestheuseofavariable level float switch for operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and...

Page 2: ...e states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state 1 Inspect and test the system for proper operations at least every 3 months a Green system ready indicator light should be on indicating AC p...

Page 3: ...pump using the clamp provided Make certain the clamp is tight on the pipe to avoid slippage Ensure that the off level of the float is 1 2 5 cm minimum above the outlet of the DC backup pump Position the pumps in the sump and move float up and down ensuring free movement without interference from any obstructions inside the sump or lid The float switch can be moved on the discharge pipe or the rubb...

Page 4: ...l recharge if green power on light indicates power has been restored and the float switch is in the off position b If immediate usage is required remove and replace dead battery with a full recharged battery c Duetovaryingconditionsthepumpmaycontinuetorunonalowbattery without sufficient power to remove water Pump will not stop running until battery is below minimum voltage d CAUTION Weak batteries...

Page 5: ...GHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT SPIN CONTROLLER HIGH WATER REED SENSOR OPTIONAL OUTLET PRIMARY PUMP OUTLET CONTROLLER OPERATIONAL FLOAT SWITCH 30 AMP FUSE HI WATER REED SENSOR OPTIONAL BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT SPIN CONTROLLER EXPLODED VIEW DC PU...

Page 6: ...SPIN Solid Flashing Off System Ready No Faults Green AC off with no faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pump Running Yellow Pump Fault Red Float Status High Water Red Sensor Activated Float Fault Red The LEDs will display information about the controller Copyright 2019 Zoeller Co All rights reserved LOCKING PIN MUST...

Page 7: ...being produced a charging battery may be producing gaseous by products which are causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of...

Page 8: ...________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________...

Reviews: