Zoeller AquaNot 508 Spin Installation Instructions Manual Download Page 5

5

FIGURE 1

SK3182

IMPORTANT

To minimize risk of air lock, intake of DC pump must be set above intake of primary pump.

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

1" MIN.

IMPORTANT: OFF LEVEL 

OF FLOAT ASSEMBLY 

MUST BE HIGHER THAN 

DC BACKUP PUMP

FIG. 1

DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP

BATTERY BOX

AQUANOT

®

 SPIN

 CONTROLLER

HIGH WATER 

REED SENSOR

(*OPTIONAL)

OUTLET

PRIMARY PUMP

OUTLET

CONTROLLER

OPERATIONAL FLOAT SWITCH

30 AMP FUSE

HI-WATER REED SENSOR

(*OPTIONAL)

BATTERY BOX

DC PUMP

12 VOLT BATTERY 

SUPPLIED BY USER

WHITE LEAD TO POSITIVE

BLACK LEAD TO NEGATIVE

CLAMP

AQUANOT

®

 SPIN

 CONTROLLER

EXPLODED VIEW - DC PUMP

FIGURE 2

SK3185

Summary of Contents for AquaNot 508 Spin

Page 1: ... tanks to pump effluent or in sewage pits to pump sewage 4 Repair and service of your DC backup system should be performed by an authorized service station 5 TheinstallationofDCautomaticbackuppumpsrequirestheuseofavariable level float switch for operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and...

Page 2: ...e states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state 1 Inspect and test the system for proper operations at least every 3 months a Green system ready indicator light should be on indicating AC p...

Page 3: ...pump using the clamp provided Make certain the clamp is tight on the pipe to avoid slippage Ensure that the off level of the float is 1 2 5 cm minimum above the outlet of the DC backup pump Position the pumps in the sump and move float up and down ensuring free movement without interference from any obstructions inside the sump or lid The float switch can be moved on the discharge pipe or the rubb...

Page 4: ...l recharge if green power on light indicates power has been restored and the float switch is in the off position b If immediate usage is required remove and replace dead battery with a full recharged battery c Duetovaryingconditionsthepumpmaycontinuetorunonalowbattery without sufficient power to remove water Pump will not stop running until battery is below minimum voltage d CAUTION Weak batteries...

Page 5: ...GHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT SPIN CONTROLLER HIGH WATER REED SENSOR OPTIONAL OUTLET PRIMARY PUMP OUTLET CONTROLLER OPERATIONAL FLOAT SWITCH 30 AMP FUSE HI WATER REED SENSOR OPTIONAL BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT SPIN CONTROLLER EXPLODED VIEW DC PU...

Page 6: ...SPIN Solid Flashing Off System Ready No Faults Green AC off with no faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pump Running Yellow Pump Fault Red Float Status High Water Red Sensor Activated Float Fault Red The LEDs will display information about the controller Copyright 2019 Zoeller Co All rights reserved LOCKING PIN MUST...

Page 7: ...being produced a charging battery may be producing gaseous by products which are causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of...

Page 8: ...________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________...