background image

FM3166

0419

Supersedes

New

12 VOLT DC BATTERY BACKUP PUMP

INSTALLATION INSTRUCTIONS

PREINSTALLATION CHECKLIST 

1.  Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.

2.  Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future 

reference.

SEE BELOW FOR 

LIST OF WARNINGS

1.  Testing for ground. As a safety measure each electrical outlet should be 

checked for ground using an Underwriters Laboratory listed circuit analyzer, 
which will indicate if the power, neutral and ground wires are correctly 

connected to your outlet. If they are not, call a qualified, licensed electrician.

2.  For your protection, always disconnect the power supply from its power 

source before handling the components of your DC backup pump or the 
primary pump.

3.  Installation and servicing of electrical circuits and hardware should be 

performed by a qualified, licensed electrician. 

4.  All electrical  and safety codes must be followed including  the National 

Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the battery and battery 
connection at least once a month. Batteries contain acid, and 

caution must be taken when handling.

6.  Risk of electric shock. These pumps have not been investigated for use in 

swimming pools and marine areas.

7.  Prop65 Warning for california residents: Cancer and Reproductive Harm- 

www.P65Warning.ca.gov.

1.  Make sure there is a properly grounded 115 V receptacle available. Do 

not use primary pump circuit.

 The location must be within 6' (1.8 m) of the 

control box and battery. The power supply for your DC control system 

plugs directly into the 115 V outlet. 

DO NOT USE AN EXTENSION CORD.

2.  Make sure the 115 V electrical supply circuit is equipped with fuses or 

circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do not use 

in septic tanks to pump effluent or in sewage pits to pump sewage.

4.  Repair and service of your DC backup system should be performed by an 

authorized service station.

5.  The installation of DC automatic backup pumps requires the use of a variable 

level float switch for operation. It is the responsibility of the installing party 

to ensure that the float switch will not hang up on the pump apparatus 

or pit peculiarities and is secured so the pump will turn “on” and “off”. 

It is recommended that the pit be 18" (45.7 cm) in diameter or larger to 

accommodate both a primary and a DC backup pump.

6.  For indoor use only.

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

CAUTION

  Turbulence caused by high-velocity incoming water can 

cause sump pumps to airlock. If this condition exists, the incoming water 

must be baffled to avoid excessive turbulence.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our web site:

zoellerpumps.com

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

Patent No. 

D740329

This equipment has been tested and found to momply with the limits for a class 

B digital device, pursuant to part 15 of the FCC Rules. These limits are designed 

to provide reasonable protection against harmful interference in a residential 

installation.  This  equipment  generates,  uses  and  can  radiate  radio  frequency 

energy and if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following 

measures: 

- Reorient or relocate the module/ product.

- Increase the separation between the equipment and module / product.

- Consult the dealer or an experienced radio / TV technician for help.

P/N 155922

Summary of Contents for AquaNot 508 Spin

Page 1: ... tanks to pump effluent or in sewage pits to pump sewage 4 Repair and service of your DC backup system should be performed by an authorized service station 5 TheinstallationofDCautomaticbackuppumpsrequirestheuseofavariable level float switch for operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and...

Page 2: ...e states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state 1 Inspect and test the system for proper operations at least every 3 months a Green system ready indicator light should be on indicating AC p...

Page 3: ...pump using the clamp provided Make certain the clamp is tight on the pipe to avoid slippage Ensure that the off level of the float is 1 2 5 cm minimum above the outlet of the DC backup pump Position the pumps in the sump and move float up and down ensuring free movement without interference from any obstructions inside the sump or lid The float switch can be moved on the discharge pipe or the rubb...

Page 4: ...l recharge if green power on light indicates power has been restored and the float switch is in the off position b If immediate usage is required remove and replace dead battery with a full recharged battery c Duetovaryingconditionsthepumpmaycontinuetorunonalowbattery without sufficient power to remove water Pump will not stop running until battery is below minimum voltage d CAUTION Weak batteries...

Page 5: ...GHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT SPIN CONTROLLER HIGH WATER REED SENSOR OPTIONAL OUTLET PRIMARY PUMP OUTLET CONTROLLER OPERATIONAL FLOAT SWITCH 30 AMP FUSE HI WATER REED SENSOR OPTIONAL BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT SPIN CONTROLLER EXPLODED VIEW DC PU...

Page 6: ...SPIN Solid Flashing Off System Ready No Faults Green AC off with no faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pump Running Yellow Pump Fault Red Float Status High Water Red Sensor Activated Float Fault Red The LEDs will display information about the controller Copyright 2019 Zoeller Co All rights reserved LOCKING PIN MUST...

Page 7: ...being produced a charging battery may be producing gaseous by products which are causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of...

Page 8: ...________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________...

Reviews: