3
© Copyright 2017 Zoeller
®
Co. All rights reserved.
Amps
Winding
Resistance
Line-to-Line
Model
RPM
Voltage
Phase
Hertz
Full Load
In Air
Shut Off
Locked Rotor
N6161
3450
115
1
60
15.5
7.7
52.2
.53/.46*
E6161
3450
230
1
60
7.5
3.6
15.1
4.74/3.88*
I6161
3450
200
1
60
8.8
6.3
19.8
3.59/2.94*
J6161
3450
200
3
60
6.4
3.1
23.6
6.25/5.12
F6161
3450
230
3
60
5.2
2.7
24.0
5.7/4.6
G6161
3450
460
3
60
2.9
1.4
12.0
22.8/18.5
BA6161
3450
575
3
60
2.4
1.3
11.3
38.0/33.0
U6161
2800
220
1
50
5.6
2.6
12.0
4.74/3.88
V6161
2800
220
1
50
5.6
2.6
12.0
4.74/3.88
AK6161
2800
380
3
50
2.0
1.3
10.0
22.8/18.5
V6162
2800
220
1
50
8
3.9
12.0
4.74/3.88
AK6162
2800
380
3
50
3
1.7
10.0
22.8/18.5
N6163
3450
115
1
60
15.0
8.4
52.2
.53/.46*
E6163
3450
230
1
60
7.5
4.0
15.1
4.74/3.88*
I6163
3450
200
1
60
8.5
4.3
19.8
3.59/2.94*
J6163
3450
200
3
60
6.0
3.4
23.6
6.25/5.12
F6163
3450
230
3
60
4.8
3.0
24.0
5.7/4.6
G6163
3450
460
3
60
2.9
1.5
12.0
22.8/18.5
BA6163
3450
575
3
60
2.4
1.5
11.3
38.0/33.0
V6163
2800
220
1
50
6.4
3.1
12.0
4.74/3.88
AK6163
2800
380
3
50
2.9
1.6
10.0
22.8/18.5
E6165
3450
230
1
60
10.2
5.5
20.1
3.06/2.51*
I6165
3450
200
1
60
12.6
6.1
26.8
2.11/1.72*
J6165
3450
200
3
60
7.5
4.1
31.1
3.74/3.06
F6165
3450
230
3
60
7.4
3.8
29.8
5.7/4.5
G6165
3450
460
3
60
3.7
2.1
14.9
22.6/18.2
BA6165
3450
575
3
60
3.0
1.7
10.0
38.8/34.5
V6165
2800
220
1
50
9.6
5.5
20.0
3.06/2.51
AK6165
2800
380
3
50
2
1.1
8.0
22.6/18.2
E6185
3450
230
1
60
9.8
5.0
20.1
3.06/2.51*
I6185
3450
200
1
60
11.5
5.1
26.8
2.11/1.72*
J6185
3450
200
3
60
7.5
3.6
31.1
3.74/3.06
F185
3450
230
3
60
7.4
3.8
29.8
5.7/4.5
G6185
3450
460
3
60
3.7
1.9
14.9
22.6/18.2
BA6185
3450
575
3
60
3.3
1.3
10.0
38.8/34.5
V6185
2800
220
1
50
10
3.9
20.0
3.06/2.51
AK6185
2800
380
3
50
4.1
1.9
17.0
13.9/11.3
E6186
3450
230
1
60
13.7
9.3
45.7
1.29/1.05*
I6186
3450
200
1
60
17.2
11.8
54.5
.86/.71*
J6186
3450
200
3
60
10.3
6.0
45.2
2.62/2.14
F186
3450
230
3
60
9.2
5.5
39.4
3.52/2.8
G6186
3450
460
3
60
4.6
2.8
19.7
13.9/11.3
E6188
3450
230
1
60
14.0
7.4
45.7
1.29/1.05*
I6188
3450
200
1
60
16.8
9.8
54.5
.86/.71*
J6188
3450
200
3
60
10.3
4.7
45.2
2.62/2.14
F6188
3450
230
3
60
8.9
4.1
39.4
3.52/2.8
G6188
3450
460
3
60
4.6
2.0
19.7
13.9/11.3
BA6188
3450
575
3
60
3.5
1.6
15.9
20.6/18.3
E6189
3450
230
1
60
17.1
9.4
45.7
1.29/1.05*
I6189
3450
200
1
60
20.5
11.5
54.5
.86/.71*
J6189
3450
200
3
60
13.2
5.9
45.2
2.62/2.14
F6189
3450
230
3
60
11.2
5.1
39.4
3.5/2.8
G6189
3450
460
3
60
6.0
2.8
19.7
13.9/11.3
BA6189
3450
575
3
60
5.8
2.1
15.9
20.6/18.3
V6189
2800
220
1
50
14.2
11.2
40.0
1.29/1.05
AK6189
2800
380
3
50
4.5
2.2
15.0
13.9/11.3
N6282
1725
115
1
60
10.3
7.3
30.2
1.46/1.20*
E6282
1725
230
1
60
5.0
4.0
15.1
5.84/4.80*
I6282
1725
200
1
60
6.1
4.5
17.7
4.65/4.05*
J6282
1725
200
3
60
3.6
2.5
12.8
8.13/6.62
F6282
1725
230
3
60
3.0
2.3
12.2
9.6/7.9
G6282
1725
460
3
60
1.7
1.1
6.1
38.4/31.5
BA6282
1725
575
3
60
1.4
1.1
5.11
63.6/55.3
V6282
1400
220
1
50
5.7
5.1
17.0
5.84/4.8
AK6282
1400
380
3
50
1.6
1.2
6.0
38.4/31.5
E6284
1725
230
1
60
8.9
6.7
24.9
2.62/2.14*
I6284
1725
200
1
60
9.3
6.4
26.8
2.01/1.82*
J6284
1725
200
3
60
5.5
4.0
26.3
2.99/2.70
F6284
1725
230
3
60
5.0
3.5
22.2
4.8/4.4
G6284
1725
460
3
60
2.6
1.9
11.1
19.2/17.4
BA6284
1725
575
3
60
2.2
1.7
12.1
20.4/17.7
N6292
3450
115
1
60
15.0
10.6
52.2
.53/.46*
E6292
3450
230
1
60
7.5
4.7
52.2
4.74/3.88*
I6292
3450
200
1
60
8.8
7.4
19.8
3.59/2.94*
Electrical Data
CONTINUED ON NEXT PAGE
* Line to line reading will only reflect the run winding resistance.
Start winding resistance can only be measured after removing the cover.