Amps

Winding

Resistance

Line-to-Line

Model

RPM

Voltage

Phase

Hertz

Full Load

In Air

Shut Off

Locked Rotor

N6161

3450

115

1

60

15.5

7.7

52.2

.53/.46*

E6161

3450

230

1

60

7.5

3.6

15.1

4.74/3.88*

I6161

3450

200

1

60

8.8

6.3

19.8

3.59/2.94*

J6161

3450

200

3

60

6.4

3.1

23.6

6.25/5.12

F6161

3450

230

3

60

5.2

2.7

24.0

5.7/4.6

G6161

3450

460

3

60

2.9

1.4

12.0

22.8/18.5

BA6161

3450

575

3

60

2.4

1.3

11.3

38.0/33.0

U6161

2800

220

1

50

5.6

2.6

12.0

4.74/3.88

V6161

2800

220

1

50

5.6

2.6

12.0

4.74/3.88

AK6161

2800

380

3

50

2.0

1.3

10.0

22.8/18.5

V6162

2800

220

1

50

8

3.9

12.0

4.74/3.88

AK6162

2800

380

3

50

3

1.7

10.0

22.8/18.5

N6163

3450

115

1

60

15.0

8.4

52.2

.53/.46*

E6163

3450

230

1

60

7.5

4.0

15.1

4.74/3.88*

I6163

3450

200

1

60

8.5

4.3

19.8

3.59/2.94*

J6163

3450

200

3

60

6.0

3.4

23.6

6.25/5.12

F6163

3450

230

3

60

4.8

3.0

24.0

5.7/4.6

G6163

3450

460

3

60

2.9

1.5

12.0

22.8/18.5

BA6163

3450

575

3

60

2.4

1.5

11.3

38.0/33.0

V6163

2800

220

1

50

6.4

3.1

12.0

4.74/3.88

AK6163

2800

380

3

50

2.9

1.6

10.0

22.8/18.5

E6165

3450

230

1

60

10.2

5.5

20.1

3.06/2.51*

I6165

3450

200

1

60

12.6

6.1

26.8

2.11/1.72*

J6165

3450

200

3

60

7.5

4.1

31.1

3.74/3.06

F6165

3450

230

3

60

7.4

3.8

29.8

5.7/4.5

G6165

3450

460

3

60

3.7

2.1

14.9

22.6/18.2

BA6165

3450

575

3

60

3.0

1.7

10.0

38.8/34.5

V6165

2800

220

1

50

9.6

5.5

20.0

3.06/2.51

AK6165

2800

380

3

50

2

1.1

8.0

22.6/18.2

E6185

3450

230

1

60

9.8

5.0

20.1

3.06/2.51*

I6185

3450

200

1

60

11.5

5.1

26.8

2.11/1.72*

J6185

3450

200

3

60

7.5

3.6

31.1

3.74/3.06

F185

3450

230

3

60

7.4

3.8

29.8

5.7/4.5

G6185

3450

460

3

60

3.7

1.9

14.9

22.6/18.2

BA6185

3450

575

3

60

3.3

1.3

10.0

38.8/34.5

V6185

2800

220

1

50

10

3.9

20.0

3.06/2.51

AK6185

2800

380

3

50

4.1

1.9

17.0

13.9/11.3

E6186

3450

230

1

60

13.7

9.3

45.7

1.29/1.05*

I6186

3450

200

1

60

17.2

11.8

54.5

.86/.71*

J6186

3450

200

3

60

10.3

6.0

45.2

2.62/2.14

F186

3450

230

3

60

9.2

5.5

39.4

3.52/2.8

G6186

3450

460

3

60

4.6

2.8

19.7

13.9/11.3

E6188

3450

230

1

60

14.0

7.4

45.7

1.29/1.05*

I6188

3450

200

1

60

16.8

9.8

54.5

.86/.71*

J6188

3450

200

3

60

10.3

4.7

45.2

2.62/2.14

F6188

3450

230

3

60

8.9

4.1

39.4

3.52/2.8

G6188

3450

460

3

60

4.6

2.0

19.7

13.9/11.3

BA6188

3450

575

3

60

3.5

1.6

15.9

20.6/18.3

E6189

3450

230

1

60

17.1

9.4

45.7

1.29/1.05*

I6189

3450

200

1

60

20.5

11.5

54.5

.86/.71*

J6189

3450

200

3

60

13.2

5.9

45.2

2.62/2.14

F6189

3450

230

3

60

11.2

5.1

39.4

3.5/2.8

G6189

3450

460

3

60

6.0

2.8

19.7

13.9/11.3

BA6189

3450

575

3

60

5.8

2.1

15.9

20.6/18.3

V6189

2800

220

1

50

14.2

11.2

40.0

1.29/1.05

AK6189

2800

380

3

50

4.5

2.2

15.0

13.9/11.3

N6282

1725

115

1

60

10.3

7.3

30.2

1.46/1.20*

E6282

1725

230

1

60

5.0

4.0

15.1

5.84/4.80*

I6282

1725

200

1

60

6.1

4.5

17.7

4.65/4.05*

J6282

1725

200

3

60

3.6

2.5

12.8

8.13/6.62

F6282

1725

230

3

60

3.0

2.3

12.2

9.6/7.9

G6282

1725

460

3

60

1.7

1.1

6.1

38.4/31.5

BA6282

1725

575

3

60

1.4

1.1

5.11

63.6/55.3

V6282

1400

220

1

50

5.7

5.1

17.0

5.84/4.8

AK6282

1400

380

3

50

1.6

1.2

6.0

38.4/31.5

E6284

1725

230

1

60

8.9

6.7

24.9

2.62/2.14*

I6284

1725

200

1

60

9.3

6.4

26.8

2.01/1.82*

J6284

1725

200

3

60

5.5

4.0

26.3

2.99/2.70

F6284

1725

230

3

60

5.0

3.5

22.2

4.8/4.4

G6284

1725

460

3

60

2.6

1.9

11.1

19.2/17.4

BA6284

1725

575

3

60

2.2

1.7

12.1

20.4/17.7

N6292

3450

115

1

60

15.0

10.6

52.2

.53/.46*

E6292

3450

230

1

60

7.5

4.7

52.2

4.74/3.88*

I6292

3450

200

1

60

8.8

7.4

19.8

3.59/2.94*

Electrical Data

CONTINUED ON NEXT PAGE

*  Line to line reading will only reflect the run winding resistance.

  Start winding resistance can only be measured after removing the cover.

Summary of Contents for 6161

Page 1: ... 6161 6163 6165 6185 6186 6188 6189 Commercial Duty Pumps Model Number ______________ Date Code _______________ Simplex Duplex Job Name ____________________________________________ Distributor ____________________________________________ Date of Purchase _________ Zoeller S O No ______________ Contractor ____________________________________________ Date of Installation ____________________________...

Page 2: ... could present a safety hazard if the insulation were to become damaged or the connection end were to fall into a damp or wet area 3 Makesurethepump selectricalsupplycircuitisequippedwithfusesorcircuitbreakers of proper capacity A separate branch circuit is recommended sized according to the governing electrical codes for the current shown on the pump name plate The pump shall be supplied through ...

Page 3: ... V6185 2800 220 1 50 10 3 9 20 0 3 06 2 51 AK6185 2800 380 3 50 4 1 1 9 17 0 13 9 11 3 E6186 3450 230 1 60 13 7 9 3 45 7 1 29 1 05 I6186 3450 200 1 60 17 2 11 8 54 5 86 71 J6186 3450 200 3 60 10 3 6 0 45 2 2 62 2 14 F186 3450 230 3 60 9 2 5 5 39 4 3 52 2 8 G6186 3450 460 3 60 4 6 2 8 19 7 13 9 11 3 E6188 3450 230 1 60 14 0 7 4 45 7 1 29 1 05 I6188 3450 200 1 60 16 8 9 8 54 5 86 71 J6188 3450 200 3...

Page 4: ... winding resistance Start winding resistance can only be measured after removing the cover 1 Pumps with power cord length less than 10 m 33 are intended for indoor use only 2 Electrical wiring and protection must be in accordance with governing electrical codes and any other applicable electrical requirements 3 Install proper Zoeller Unicheck combination union and check valve preferably just above...

Page 5: ...ne moisture sensor hookup per pump one moisture sensor lead from the pump should be hooked to the moisture sensor lead in the panel the other moisture sensor lead from the pump should be hooked to ground to complete the circuit 6 Moisture sensor circuit can be checked for continuity complete circuit with a Volt OHM Meter Set the VOM to read resistance and connect the VOM leads to the sensor cord b...

Page 6: ...ANDLING To automatically operate a nonautomatic three phase pump acontrolpanelisrequired Followtheinstructions provided with the panel to wire the system Before installing a pump check the pump rotation to ensurethatwiringhasbeenconnectedproperlytopower source andthatthegreenleadofpowercord seewiring diagram is connected to a valid ground Momentarily energizethepump observingthedirectionsofkickbac...

Page 7: ...perly sealed Thermal overload adjustments made in the panel After installing the pump into the containment area with adequate submergence open the discharge valve fully Start the unit using manual controls If flow is appreciably less than rated performance pump may be air locked To expel trapped air jog the unit several times using the manual controls Haveaqualifiedelectriciantakevoltageandcurrent...

Page 8: ...any or a qualified licensed electrician to disconnect electrical service prior to pump removal Pumpcontainsoilwhichbecomespressurizedandhotwhenoperating Allow2 1 2hoursafterdisconnectingbeforeattemptingservice MAILTO P O BOX 16347 Louisville KY 40256 0347 USA SHIPTO 3649 Cane Run Road Louisville KY 40211 1961 USA 1 502 778 2731 FAX 1 502 774 3624 visit our web site zoellerengineered com DECLARATIO...

Reviews: